Comparison of three autotransfusion devices for utilization in the pediatric population.

autotransfusion blood conservation cardiopulmonary bypass extracorporeal technology pediatric

Journal

Perfusion
ISSN: 1477-111X
Titre abrégé: Perfusion
Pays: England
ID NLM: 8700166

Informations de publication

Date de publication:
01 2021
Historique:
pubmed: 2 6 2020
medline: 25 11 2021
entrez: 2 6 2020
Statut: ppublish

Résumé

A device that may help attenuate the amount of homologous blood product given to pediatric cardiac surgical patients is the autotransfusion device. Three separate autotransfusion devices were selected for evaluation. The Sorin Xtra, Fresenius Continuous Autotransfusion System Plus (CATS Each of the autotransfusion devices were used to collect salvageable blood from the surgical field as well as to process residual blood from the cardiopulmonary bypass circuit after decannulation. The cell salvage process was performed in accordance with the manufacturer's instructions for use and the recommended settings for processing and washing. The Sorin Xtra device had the 55 mL bowl set up for all cases, while the Fresenius continuous autotransfusion systems utilized the standard disposable for each device. Each cell salvage device was employed during 30 pediatric cardiac surgery procedures, and data for each device, was broken down into four groups based on patient weight (0-10, 10-20, 20-40, and >40 kg). For all patient sizes, the Sorin Xtra tended to produce the greatest volume of cell saver product (55-825 mL) as compared to the CATS Through this evaluation, it was determined the continuous autotransfusion systems provided the highest hematocrit with the lowest recovered packed red cell volume, while the Sorin Xtra packed red cell product showed to have a lower hematocrit with a larger packed red cell volume. Each device proved effective within our pediatric population.

Identifiants

pubmed: 32475210
doi: 10.1177/0267659120921090
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

57-62

Auteurs

Richard W Melchior (RW)

Department of Perfusion Services, Cardiac Center, Children's Hospital of Philadelphia, Philadelphia, PA, USA.

Molly Dreher (M)

Department of Perfusion Services, Cardiac Center, Children's Hospital of Philadelphia, Philadelphia, PA, USA.

Brandon Shade (B)

Department of Perfusion Services, Cardiac Center, Children's Hospital of Philadelphia, Philadelphia, PA, USA.

Alexander Chappell (A)

Department of Perfusion Services, Cardiac Center, Children's Hospital of Philadelphia, Philadelphia, PA, USA.

Douglas Fisher (D)

Department of Perfusion Services, Cardiac Center, Children's Hospital of Philadelphia, Philadelphia, PA, USA.

Tami Rosenthal (T)

Department of Perfusion Services, Cardiac Center, Children's Hospital of Philadelphia, Philadelphia, PA, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH