Analysis of the Binding of Analyte-Receptor in a Micro-Fluidic Channel for a Biosensor based on Brownian Motion.
biosensor
specific binding of analyte-receptor
transport model for micro-fluidic channel based on Brownian motion
Journal
Micromachines
ISSN: 2072-666X
Titre abrégé: Micromachines (Basel)
Pays: Switzerland
ID NLM: 101640903
Informations de publication
Date de publication:
03 Jun 2020
03 Jun 2020
Historique:
received:
06
05
2020
revised:
29
05
2020
accepted:
02
06
2020
entrez:
7
6
2020
pubmed:
7
6
2020
medline:
7
6
2020
Statut:
epublish
Résumé
This study experimentally analyses the binding characteristics of analytes mixed in liquid samples flowing along a micro-channel to the receptor fixed on the wall of the micro-channel to provide design tools and data for a microfluidic-based biosensor. The binding or detection characteristics are analyzed experimentally by counting the number of analytes bound to the receptor, with sample analyte concentration, sample flow rate, and the position of the receptor along the micro-channel length as the main variables. A mathematical model is also proposed to predict the number of analytes transported and bound to the receptor based on a probability density function for Brownian motion. The coefficient in the mathematical model is obtained by using a dimensionless mathematical model and the experimental results. The coefficient remains valid for all different conditions of the sample analyte concentration, flow rate, and the position of the receptor, which implies the possibility of deriving a generalized model. Based on the mathematical model derived from mathematical and experimental analysis on the detection characteristics of the microfluidic-based biosensor depending on previously mentioned variables and the height of the micro-channel, this study suggests a design for a microfluidic-based biosensor by predicting the binding efficiency according to the channel height. The results show the binding efficiency increases as the flow rate decreases and as the receptor is placed closer to the sample-injecting inlet, but is unaffected by sample concentration.
Identifiants
pubmed: 32503275
pii: mi11060570
doi: 10.3390/mi11060570
pmc: PMC7346006
pii:
doi:
Types de publication
Journal Article
Langues
eng
Subventions
Organisme : Ministry of Science and ICT, South Korea
ID : 2018M 3C 1B9069841
Organisme : Korea Institute of Machinery and Materials
ID : NK226E
Déclaration de conflit d'intérêts
The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.
Références
Biosens Bioelectron. 1998 Oct 1;13(7-8):731-9
pubmed: 9828367
Biosens Bioelectron. 2013 Oct 15;48:132-7
pubmed: 23669045
J Biophotonics. 2012 Jul;5(7):483-501
pubmed: 22467335
Biochemistry. 2000 Aug 22;39(33):10219-23
pubmed: 10956011
Anal Chim Acta. 2012 May 21;727:67-70
pubmed: 22541825
Anal Chim Acta. 2012 Aug 6;737:1-21
pubmed: 22769031
Anal Chem. 2014 May 6;86(9):4278-86
pubmed: 24684138
Biosens Bioelectron. 2007 Dec 15;23(5):741-5
pubmed: 17723292
J Phys Chem B. 2005 Sep 8;109(35):16988-96
pubmed: 16853163
Front Bioeng Biotechnol. 2016 Feb 16;4:11
pubmed: 26909346
Anal Chim Acta. 2014 Aug 1;838:64-75
pubmed: 25064245
Biosens Bioelectron. 2014 Apr 15;54:506-14
pubmed: 24321884
Biotechnol Appl Biochem. 2018 May;65(3):497-508
pubmed: 29023994
Chem Soc Rev. 2013 Apr 21;42(8):3184-96
pubmed: 23420144
Essays Biochem. 2016 Jun 30;60(1):1-8
pubmed: 27365030
FEBS Lett. 1996 Jul 22;390(2):161-4
pubmed: 8706850
Biosens Bioelectron. 2007 May 15;22(11):2763-7
pubmed: 17223338
Sensors (Basel). 2013 May 14;13(5):6423-47
pubmed: 23673681
Phys Fluids (1994). 2011 Jul;23(7):73602-7360215
pubmed: 21918592
Biosens Bioelectron. 2017 Jan 15;87:433-438
pubmed: 27589408