Bony increased-offset-reverse shoulder arthroplasty: 5 to 10 years' follow-up.
Adult
Aged
Aged, 80 and over
Arthroplasty, Replacement, Shoulder
/ adverse effects
Bone Transplantation
Female
Follow-Up Studies
Glenoid Cavity
/ surgery
Humans
Male
Middle Aged
Patient Satisfaction
Prosthesis Failure
Range of Motion, Articular
Reoperation
Shoulder Joint
/ diagnostic imaging
Shoulder Prosthesis
/ adverse effects
Tomography, X-Ray Computed
Treatment Outcome
Young Adult
Reverse shoulder arthroplasty
bony increased-offset–reverse shoulder arthroplasty (BIO-RSA)
glenoid bone graft
glenoid inclination
glenoid lateralization
scapular notching
Journal
Journal of shoulder and elbow surgery
ISSN: 1532-6500
Titre abrégé: J Shoulder Elbow Surg
Pays: United States
ID NLM: 9206499
Informations de publication
Date de publication:
Oct 2020
Oct 2020
Historique:
received:
01
11
2019
revised:
03
02
2020
accepted:
10
02
2020
pubmed:
9
6
2020
medline:
25
2
2021
entrez:
8
6
2020
Statut:
ppublish
Résumé
Glenoid lateralization has been shown to be the most imortant factor in maximizing passive range of motion and shoulder stability while preventing scapular impingement and notching. We aimed to evaluate mid- to long-term functional and radiologic outcomes after bony increased-offset-reverse shoulder arthroplasty (BIO-RSA) using a Grammont-style (medialized) humeral implant. The study included 143 consecutive shoulders (140 patients; mean age, 72 years) treated with a BIO-RSA for rotator cuff deficiency. A cylinder of autologous cancellous bone graft, harvested from the humeral head, was placed between the reamed glenoid surface and baseplate; fixation was achieved using a long central peg (25 mm) and 4 screws. A large baseplate (29 mm) with a small baseplate sphere (36 mm) was used in 77% of cases, and a Grammont-style (medialized) humeral implant with 155° of inclination was used in all cases. All patients underwent clinical and radiographic assessment at a minimum of 5 years after surgery; in addition, 86 cases (60%) underwent computed tomography scan assessment. At a mean follow-up of 75 months (range, 60-126 months), the survivorship of the BIO-RSA using revision as an endpoint was 96%. No cases of dislocation or humeral loosening were observed. Overall, 118 patients (83%) were either very satisfied (61%) or satisfied (22%). The adjusted Constant score improved from 40% ± 18% to 93% ± 23%, and the Subjective Shoulder Value improved from 31% ± 15% to 77% ± 18% (P < .001). The humeral bone graft incorporated completely in 96% of cases (137 of 143). Severe inferior scapular notching (grade 3 or 4) occurred in 18% (24 of 136). The risk of postoperative notching correlated to a lower body mass index (P < .05), superior glenosphere inclination (P = .02), and high or flush glenosphere positioning (P = .035). BIO-RSA is a safe and effective technique to lateralize the glenoid, providing consistent bone graft healing, excellent functional outcomes, a low revision rate, and a high rate of patient satisfaction. Thin patients (with a low body mass index) and glenosphere malposition (with persistent superior inclination and/or insufficient lowering of the baseplate and sphere) are associated with higher risk of scapular notching.Our data confirm the importance of implanting the baseplate with a neutral inclination (reverse shoulder arthroplasty angle < 5°) and with sufficient glenosphere inferior overhang (>5 mm) in preventing scapular notching. The use of a less medialized humeral implant (135° or 145° inclined) and smaller (25-mm) baseplate (when using a small, 36-mm sphere) should allow reduction in the incidence of scapular notching.
Sections du résumé
BACKGROUND
BACKGROUND
Glenoid lateralization has been shown to be the most imortant factor in maximizing passive range of motion and shoulder stability while preventing scapular impingement and notching. We aimed to evaluate mid- to long-term functional and radiologic outcomes after bony increased-offset-reverse shoulder arthroplasty (BIO-RSA) using a Grammont-style (medialized) humeral implant.
METHODS
METHODS
The study included 143 consecutive shoulders (140 patients; mean age, 72 years) treated with a BIO-RSA for rotator cuff deficiency. A cylinder of autologous cancellous bone graft, harvested from the humeral head, was placed between the reamed glenoid surface and baseplate; fixation was achieved using a long central peg (25 mm) and 4 screws. A large baseplate (29 mm) with a small baseplate sphere (36 mm) was used in 77% of cases, and a Grammont-style (medialized) humeral implant with 155° of inclination was used in all cases. All patients underwent clinical and radiographic assessment at a minimum of 5 years after surgery; in addition, 86 cases (60%) underwent computed tomography scan assessment.
RESULTS
RESULTS
At a mean follow-up of 75 months (range, 60-126 months), the survivorship of the BIO-RSA using revision as an endpoint was 96%. No cases of dislocation or humeral loosening were observed. Overall, 118 patients (83%) were either very satisfied (61%) or satisfied (22%). The adjusted Constant score improved from 40% ± 18% to 93% ± 23%, and the Subjective Shoulder Value improved from 31% ± 15% to 77% ± 18% (P < .001). The humeral bone graft incorporated completely in 96% of cases (137 of 143). Severe inferior scapular notching (grade 3 or 4) occurred in 18% (24 of 136). The risk of postoperative notching correlated to a lower body mass index (P < .05), superior glenosphere inclination (P = .02), and high or flush glenosphere positioning (P = .035).
CONCLUSIONS
CONCLUSIONS
BIO-RSA is a safe and effective technique to lateralize the glenoid, providing consistent bone graft healing, excellent functional outcomes, a low revision rate, and a high rate of patient satisfaction. Thin patients (with a low body mass index) and glenosphere malposition (with persistent superior inclination and/or insufficient lowering of the baseplate and sphere) are associated with higher risk of scapular notching.Our data confirm the importance of implanting the baseplate with a neutral inclination (reverse shoulder arthroplasty angle < 5°) and with sufficient glenosphere inferior overhang (>5 mm) in preventing scapular notching. The use of a less medialized humeral implant (135° or 145° inclined) and smaller (25-mm) baseplate (when using a small, 36-mm sphere) should allow reduction in the incidence of scapular notching.
Identifiants
pubmed: 32505414
pii: S1058-2746(20)30209-3
doi: 10.1016/j.jse.2020.02.008
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
2111-2122Informations de copyright
Copyright © 2020. Published by Elsevier Inc.