Résumé

Kinematic alignment recently became an alternative alignment option for total knee arthroplasty (TKA). Beside previous studies assessing mechanical alignment in comparison to unintentional malalignment of TKA in terms of implant survival and clinical outcome, more and more studies have focused on the direct comparison of intentional kinematic alignment with mechanical alignment of the prosthesis. In the past 5 years the number of studies with respect to kinematic alignment has risen from 11 to 91 studies. The aim of this review article is to give a narrative overview of the current literature in the debate concerning kinematic and mechanical alignment in TKA. HINTERGRUND: Das kinematische Alignment hat sich in den letzten Jahren zu einer etablierten Methode in der Knieendoprothetik entwickelt. Neben früheren Studien, welche die mechanische Ausrichtung im Vergleich zur unbeabsichtigten Fehlpositionierung der Knieendoprothese (Varus- und Valgusfehlstellung) im Hinblick auf das Implantatüberleben und das klinische Ergebnis untersuchten, konzentrieren sich immer mehr Studien auf den direkten Vergleich der kinematischen und mechanischen Prothesenausrichtung. In den letzten 5 Jahren ist die Anzahl der Studien zum kinematischen Alignment von rund 11 auf 91 Studien gestiegen. ZIEL: Das Ziel dieses Beitrags ist es, einen Überblick über die aktuelle Literaturlage hinsichtlich des kinematischen im Vergleich zum mechanischen Alignment in der Knietotalendoprothetik zu geben.

Sections du résumé

BACKGROUND BACKGROUND
Kinematic alignment recently became an alternative alignment option for total knee arthroplasty (TKA). Beside previous studies assessing mechanical alignment in comparison to unintentional malalignment of TKA in terms of implant survival and clinical outcome, more and more studies have focused on the direct comparison of intentional kinematic alignment with mechanical alignment of the prosthesis. In the past 5 years the number of studies with respect to kinematic alignment has risen from 11 to 91 studies.
AIM OBJECTIVE
The aim of this review article is to give a narrative overview of the current literature in the debate concerning kinematic and mechanical alignment in TKA.
ZUSAMMENFASSUNG UNASSIGNED
HINTERGRUND: Das kinematische Alignment hat sich in den letzten Jahren zu einer etablierten Methode in der Knieendoprothetik entwickelt. Neben früheren Studien, welche die mechanische Ausrichtung im Vergleich zur unbeabsichtigten Fehlpositionierung der Knieendoprothese (Varus- und Valgusfehlstellung) im Hinblick auf das Implantatüberleben und das klinische Ergebnis untersuchten, konzentrieren sich immer mehr Studien auf den direkten Vergleich der kinematischen und mechanischen Prothesenausrichtung. In den letzten 5 Jahren ist die Anzahl der Studien zum kinematischen Alignment von rund 11 auf 91 Studien gestiegen. ZIEL: Das Ziel dieses Beitrags ist es, einen Überblick über die aktuelle Literaturlage hinsichtlich des kinematischen im Vergleich zum mechanischen Alignment in der Knietotalendoprothetik zu geben.

Autres résumés

Type: Publisher (ger)
HINTERGRUND: Das kinematische Alignment hat sich in den letzten Jahren zu einer etablierten Methode in der Knieendoprothetik entwickelt. Neben früheren Studien, welche die mechanische Ausrichtung im Vergleich zur unbeabsichtigten Fehlpositionierung der Knieendoprothese (Varus- und Valgusfehlstellung) im Hinblick auf das Implantatüberleben und das klinische Ergebnis untersuchten, konzentrieren sich immer mehr Studien auf den direkten Vergleich der kinematischen und mechanischen Prothesenausrichtung. In den letzten 5 Jahren ist die Anzahl der Studien zum kinematischen Alignment von rund 11 auf 91 Studien gestiegen. ZIEL: Das Ziel dieses Beitrags ist es, einen Überblick über die aktuelle Literaturlage hinsichtlich des kinematischen im Vergleich zum mechanischen Alignment in der Knietotalendoprothetik zu geben.

Identifiants

pubmed: 32507940
doi: 10.1007/s00132-020-03932-6
pii: 10.1007/s00132-020-03932-6
doi:

Types de publication

Journal Article Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

584-592

Références

Abdel MP, Ollivier M, Parratte S, Trousdale RT, Berry DJ, Pagnano MW (2018) Effect of postoperative mechanical axis alignment on survival and functional outcomes of modern total knee arthroplasties with cement: a concise follow-up at 20 years. J Bone Joint Surg Am 100:472–478. https://doi.org/10.2106/JBJS.16.01587
doi: 10.2106/JBJS.16.01587
Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183
Bellemans J, Colyn W, Vandenneucker H, Victor J (2012) The Chitranjan Ranawat award: Is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 470:45–53. https://doi.org/10.1007/s11999-011-1936-5
doi: 10.1007/s11999-011-1936-5
Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) The Chetranjan Ranawat award: tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34. https://doi.org/10.1097/01.blo.0000148578.22729.0e
doi: 10.1097/01.blo.0000148578.22729.0e
Blakeney W, Clément J, Desmeules F, Hagemeister N, Rivière C, Vendittoli P‑A (2019) Kinematic alignment in total knee arthroplasty better reproduces normal gait than mechanical alignment. Knee Surg Sports Traumatol Arthrosc 27:1410–1417. https://doi.org/10.1007/s00167-018-5174-1
doi: 10.1007/s00167-018-5174-1
Bonner TJ, Eardley WGP, Patterson P, Gregg PJ (2011) The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg Br 93-B:1217–1222. https://doi.org/10.1302/0301-620X.93B9.26573
doi: 10.1302/0301-620X.93B9.26573
Calliess T, Bauer K, Stukenborg-Colsman C, Windhagen H, Budde S, Ettinger M (2017) PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc 25:1743–1748. https://doi.org/10.1007/s00167-016-4136-8
doi: 10.1007/s00167-016-4136-8
Collier MB, Engh CA Jr, Engh GA (2004) Shelf age of the polyethylene tibial component and outcome of unicondylar knee arthroplasty. J Bone Joint Surg Am 86:763–769. https://doi.org/10.2106/00004623-200404000-00014
doi: 10.2106/00004623-200404000-00014 pubmed: 15069141
Courtney PM, Lee G‑C (2017) Early outcomes of kinematic alignment in primary total knee arthroplasty: a meta-analysis of the literature. J Arthroplasty 32:2028–2032.e1. https://doi.org/10.1016/j.arth.2017.02.041
doi: 10.1016/j.arth.2017.02.041 pubmed: 28341278
D’Lima DD, Chen PC, Colwell CW (2001) Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthop Relat Res 392:232–238. https://doi.org/10.1097/00003086-200111000-00029
doi: 10.1097/00003086-200111000-00029
D’Lima DD, Hermida JC, Chen PC, Colwell CW (2001) Polyethylene wear and variations in knee kinematics. Clin Orthop Relat Res 392:124–130. https://doi.org/10.1097/00003086-200111000-00015
doi: 10.1097/00003086-200111000-00015
Dossett HG, Estrada NA, Swartz GJ, LeFevre GW, Kwasman BG (2014) A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results. Bone Joint J 96-B:907–913. https://doi.org/10.1302/0301-620X.96B7.32812
doi: 10.1302/0301-620X.96B7.32812
Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty. J Arthroplasty 24:39–43. https://doi.org/10.1016/j.arth.2009.04.034
doi: 10.1016/j.arth.2009.04.034
van Hamersveld KT, Marang-van de Mheen PJ, Nelissen RGHH (2019) The effect of coronal alignment on tibial component migration following total knee arthroplasty: a cohort study with long-term radiostereometric analysis results. J Bone Joint Surg Am 101:1203–1212. https://doi.org/10.2106/JBJS.18.00691
doi: 10.2106/JBJS.18.00691 pubmed: 31274722
Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML (2013) Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 471:1000–1007. https://doi.org/10.1007/s11999-012-2613-z
doi: 10.1007/s11999-012-2613-z
Howell SM, Shelton TJ, Hull ML (2018) Implant survival and function ten years after kinematically aligned total knee arthroplasty. J Arthroplasty 33:3678–3684. https://doi.org/10.1016/j.arth.2018.07.020
doi: 10.1016/j.arth.2018.07.020 pubmed: 30122435
Ishikawa M, Kuriyama S, Ito H, Furu M, Nakamura S, Matsuda S (2015) Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: a case study on a single implant design. Knee 22:206–212. https://doi.org/10.1016/j.knee.2015.02.019
doi: 10.1016/j.knee.2015.02.019
Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714
doi: 10.1302/0301-620X.73B5.1894655
Ji H‑M, Han J, Jin DS, Seo H, Won Y‑Y (2016) Kinematically aligned TKA can align knee joint line to horizontal. Knee Surg Sports Traumatol Arthrosc 24:2436–2441. https://doi.org/10.1007/s00167-016-3995-3
doi: 10.1007/s00167-016-3995-3
Khatib Y, Xia A, Naylor JM, Harris IA, Sorial RM (2019) Different targets of mechanical alignment do not improve knee outcomes after TKA. Knee 26:1395–1402. https://doi.org/10.1016/j.knee.2019.08.004
doi: 10.1016/j.knee.2019.08.004 pubmed: 31477332
Kim J‑T, Han J, Lim S, Shen QH, Won YY (2019) Kinematically aligned TKA aligns the ankle joint line closer to those of the native ankle than mechanically aligned TKA in bipedal stance. J Knee Surg 32:1033–1038. https://doi.org/10.1055/s-0039-1694796
doi: 10.1055/s-0039-1694796 pubmed: 31434142
Kim Y‑H, Park J‑W, Kim J‑S (2012) Computer-navigated versus conventional total knee arthroplasty: a prospective randomized trial. J Bone Joint Surg Am 94:2017–2024. https://doi.org/10.2106/JBJS.L.00142
doi: 10.2106/JBJS.L.00142 pubmed: 23052635
Kim Y‑H, Park J‑W, Kim J‑S, Park S‑D (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. International Orthopaedics (SICOT) 38:379–385. https://doi.org/10.1007/s00264-013-2097-9
doi: 10.1007/s00264-013-2097-9
Kutzner I, Bender A, Dymke J, Duda G, von Roth P, Bergmann G (2017) Mediolateral force distribution at the knee joint shifts across activities and is driven by tibiofemoral alignment. Bone Joint J 99-B:779–787. https://doi.org/10.1302/0301-620X.99B6.BJJ-2016-0713.R1
doi: 10.1302/0301-620X.99B6.BJJ-2016-0713.R1 pubmed: 28566397
Laende EK, Richardson CG, Dunbar MJ (2019) A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty. Bone Joint J 101-B:929–940. https://doi.org/10.1302/0301-620X.101B8.BJJ-2018-0755.R3
doi: 10.1302/0301-620X.101B8.BJJ-2018-0755.R3 pubmed: 31362561
Li Y‑R, Gao Y‑H, Yang C, Ding L, Zhang X, Chen H, Liu J, Qi X (2019) Finite-element analysis of the proximal tibial sclerotic bone and different alignment in total knee arthroplasty. BMC Musculoskelet Disord 20:617. https://doi.org/10.1186/s12891-019-3008-z
doi: 10.1186/s12891-019-3008-z pubmed: 31878972 pmcid: 6933927
Liau J‑J, Cheng C‑K, Huang C‑H, Lo W‑H (2002) The effect of malalignment on stresses in polyethylene component of total knee prostheses—a finite element analysis. Clin Biomech 17:140–146. https://doi.org/10.1016/S0268-0033(01)00109-7
doi: 10.1016/S0268-0033(01)00109-7
Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79
doi: 10.2106/00004623-197759010-00013
Luyckx T, Vandenneucker H, Ing LS, Vereecke E, Ing AV, Victor J (2018) Raising the joint line in TKA is associated with mid-flexion laxity: a study in cadaver knees. Clin Orthop Relat Res 476:601–611. https://doi.org/10.1007/s11999.0000000000000067
doi: 10.1007/s11999.0000000000000067 pubmed: 29443845 pmcid: 6260050
MacDessi SJ, Griffiths-Jones W, Chen DB, Griffiths-Jones S, Wood JA, Diwan AD, Harris IA (2020) Restoring the constitutional alignment with a restrictive kinematic protocol improves quantitative soft-tissue balance in total knee arthroplasty: a randomized controlled trial. Bone Joint J 102-B:117–124. https://doi.org/10.1302/0301-620X.102B1.BJJ-2019-0674.R2
doi: 10.1302/0301-620X.102B1.BJJ-2019-0674.R2 pubmed: 31888372
Magnussen RA, Weppe F, Demey G, Servien E, Lustig S (2011) Residual varus alignment does not compromise results of TKAs in patients with preoperative varus. Clin Orthop Relat Res 469:3443–3450. https://doi.org/10.1007/s11999-011-1988-6
doi: 10.1007/s11999-011-1988-6 pubmed: 21789710 pmcid: 3210258
Matsuda S, Whiteside LA, White SE (1999) The effect of varus tilt on contact stresses in total knee arthroplasty: a biomechanical study. Orthopedics 22:303–307
pubmed: 10192260
Matsumoto T, Takayama K, Ishida K, Hayashi S, Hashimoto S, Kuroda R (2017) Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty. Bone Joint J 99-B:640–646. https://doi.org/10.1302/0301-620X.99B5.BJJ-2016-0688.R2
doi: 10.1302/0301-620X.99B5.BJJ-2016-0688.R2
Matsumoto T, Takayama K, Ishida K, Kuroda Y, Tsubosaka M, Muratsu H, Hayashi S, Hashimoto S, Matsushita T, Niikura T, Kuroda R (2019) Intraoperative soft tissue balance/kinematics and clinical evaluation of modified kinematically versus mechanically aligned total knee arthroplasty. J Knee Surg. https://doi.org/10.1055/s-0039-1688504
doi: 10.1055/s-0039-1688504 pubmed: 31891963
Matziolis G, Adam J, Perka C (2010) Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement. Arch Orthop Trauma Surg 130:1487–1491. https://doi.org/10.1007/s00402-010-1064-9
doi: 10.1007/s00402-010-1064-9 pubmed: 20165859
McEwen PJ, Dlaska CE, Jovanovic IA, Doma K, Brandon BJ (2019) Computer-assisted kinematic and mechanical axis total knee arthroplasty: a prospective randomized controlled trial of bilateral simultaneous surgery. J Arthroplasty. https://doi.org/10.1016/j.arth.2019.08.064
doi: 10.1016/j.arth.2019.08.064 pubmed: 31591010
Morgan SS, Bonshahi A, Pradhan N, Gregory A, Gambhir A, Porter ML (2008) The influence of postoperative coronal alignment on revision surgery in total knee arthroplasty. Int Orthop 32:639–642. https://doi.org/10.1007/s00264-007-0391-0
doi: 10.1007/s00264-007-0391-0
Nakajima A, Sonobe M, Akatsu Y, Aoki Y, Takahashi H, Suguro T, Nakagawa K (2018) Association between limb alignment and patient-reported outcomes after total knee arthroplasty using an implant that reproduces anatomical geometry. J Orthop Surg Res 13:320. https://doi.org/10.1186/s13018-018-1030-8
doi: 10.1186/s13018-018-1030-8 pubmed: 30558616 pmcid: 6296124
Nakamura S, Tian Y, Tanaka Y, Kuriyama S, Ito H, Furu M, Matsuda S (2017) The effects of kinematically aligned total knee arthroplasty on stress at the medial tibia: a case study for varus knee. Bone Joint Res 6:43–51. https://doi.org/10.1302/2046-3758.61.BJR-2016-0090.R1
doi: 10.1302/2046-3758.61.BJR-2016-0090.R1 pubmed: 5301901 pmcid: 5301901
Ng CK, Chen JY, Yeh JZY, Ho JPY, Merican AM, Yeo SJ (2018) Distal femoral rotation correlates with proximal tibial joint line obliquity: a consideration for kinematic total knee arthroplasty. J Arthroplasty 33:1936–1944. https://doi.org/10.1016/j.arth.2017.12.025
doi: 10.1016/j.arth.2017.12.025 pubmed: 29395720
Niki Y, Nagura T, Kobayashi S, Udagawa K, Harato K (2019) Who will benefit from kinematically aligned total knee arthroplasty? Perspectives on patient-reported outcome measures. J Arthroplasty. https://doi.org/10.1016/j.arth.2019.09.035
doi: 10.1016/j.arth.2019.09.035 pubmed: 31668528
Niki Y, Nagura T, Nagai K, Kobayashi S, Harato K (2018) Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 26:1629–1635. https://doi.org/10.1007/s00167-017-4788-z
doi: 10.1007/s00167-017-4788-z
Nishida K, Matsumoto T, Takayama K, Ishida K, Nakano N, Matsushita T, Kuroda R, Kurosaka M (2017) Remaining mild varus limb alignment leads to better clinical outcome in total knee arthroplasty for varus osteoarthritis. Knee Surg Sports Traumatol Arthrosc 25:3488–3494. https://doi.org/10.1007/s00167-016-4260-5
doi: 10.1007/s00167-016-4260-5 pubmed: 27506810
Pang H‑N, Jamieson P, Teeter MG, McCalden RW, Naudie DDR, MacDonald SJ (2014) Retrieval analysis of posterior stabilized polyethylene tibial inserts and its clinical relevance. J Arthroplasty 29:365–368. https://doi.org/10.1016/j.arth.2013.05.029
doi: 10.1016/j.arth.2013.05.029 pubmed: 23809707
Park J‑K, Seon J‑K, Cho K‑J, Lee N‑H, Song E‑K (2018) Is immediate postoperative mechanical axis associated with the revision rate of primary total knee arthroplasty? A 10-year follow-up study. Clin Orthop Surg 10:167. https://doi.org/10.4055/cios.2018.10.2.167
doi: 10.4055/cios.2018.10.2.167 pubmed: 29854339 pmcid: 5964264
Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am 92:2143–2149. https://doi.org/10.2106/JBJS.I.01398
doi: 10.2106/JBJS.I.01398
Perillo-Marcone A, Barrett DS, Taylor M (2000) The importance of tibial alignment. J Arthroplasty 15:1020–1027. https://doi.org/10.1054/arth.2000.17941
doi: 10.1054/arth.2000.17941 pubmed: 11112199
Petterwood J, Dowsey MM, Rodda D, Choong PFM (2014) The immediate post-operative radiograph is an unreliable measure of coronal plane alignment in total knee replacement. Front Surg. https://doi.org/10.3389/fsurg.2014.00035
doi: 10.3389/fsurg.2014.00035 pubmed: 25593959 pmcid: 4287011
Rassir R, van de Bunt F, Sierevelt IN, Nolte PA (2019) The value of postoperative prosthesis alignment and patellar height measurements on standard X‑rays after total knee arthroplasty: Does it relate to knee function after 5 years? Knee 26:213–221. https://doi.org/10.1016/j.knee.2018.09.014
doi: 10.1016/j.knee.2018.09.014 pubmed: 30467023
Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am 93:1588–1596. https://doi.org/10.2106/JBJS.J.00772
doi: 10.2106/JBJS.J.00772
Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156
Rivière C, Lazic S, Boughton O, Wiart Y, Vïllet L, Cobb J (2018) Current concepts for aligning knee implants: patient-specific or systematic? EFORT Open Rev 3:1–6. https://doi.org/10.1302/2058-5241.3.170021
doi: 10.1302/2058-5241.3.170021 pubmed: 29657839 pmcid: 5890125
Roth JD, Howell SM, Hull ML (2018) Kinematically aligned total knee arthroplasty limits high tibial forces, differences in tibial forces between compartments, and abnormal tibial contact kinematics during passive flexion. Knee Surg Sports Traumatol Arthrosc 26:1589–1601. https://doi.org/10.1007/s00167-017-4670-z
doi: 10.1007/s00167-017-4670-z
Salzmann M, Fennema P, Becker R, Hommel H (2017) Does postoperative mechanical axis alignment have an effect on clinical outcome of primary total knee arthroplasty? A retrospective cohort study. Open Orthop J 11:1330–1336. https://doi.org/10.2174/1874325001711011330
doi: 10.2174/1874325001711011330 pubmed: 29290871 pmcid: 5721318
Shelton TJ, Gill M, Athwal G, Howell SM, Hull ML (2019) Outcomes in patients with a calipered kinematically aligned TKA that already had a contralateral mechanically aligned TKA. J Knee Surg. https://doi.org/10.1055/s-0039-1693000
doi: 10.1055/s-0039-1693000 pubmed: 31499569
Shelton TJ, Nedopil AJ, Howell SM, Hull ML (2017) Do varus or valgus outliers have higher forces in the medial or lateral compartments than those which are in-range after a kinematically aligned total knee arthroplasty?: Limb and joint line alignment after kinematically aligned total knee arthroplasty. Bone Joint J 99-B:1319–1328. https://doi.org/10.1302/0301-620X.99B10.BJJ-2017-0066.R1
doi: 10.1302/0301-620X.99B10.BJJ-2017-0066.R1
Skyttä ET, Lohman M, Tallroth K, Remes V (2009) Comparison of standard anteroposterior knee and hip-to-ankle radiographs in determining the lower limb and implant alignment after total knee arthroplasty. Scand J Surg 98:250–253. https://doi.org/10.1177/145749690909800411
doi: 10.1177/145749690909800411 pubmed: 20218424
Srivastava A, Lee GY, Steklov N, Colwell CW, Ezzet KA, D’Lima DD (2012) Effect of tibial component varus on wear in total knee arthroplasty. Knee 19:560–563. https://doi.org/10.1016/j.knee.2011.11.003
doi: 10.1016/j.knee.2011.11.003
Takahashi T, Ansari J, Pandit H (2018) Kinematically aligned total knee arthroplasty or mechanically aligned total knee arthroplasty. J Knee Surg 31:999–1006. https://doi.org/10.1055/s-0038-1632378
doi: 10.1055/s-0038-1632378
Teeter MG, Naudie DD, McCalden RW, Yuan X, Holdsworth DW, MacDonald SJ, Lanting BA (2018) Varus tibial alignment is associated with greater tibial baseplate migration at 10 years following total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 26:1610–1617. https://doi.org/10.1007/s00167-017-4765-6
doi: 10.1007/s00167-017-4765-6
Tew M, Waugh W (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg Br 67:551–556
doi: 10.1302/0301-620X.67B4.4030849
Vanlommel L, Vanlommel J, Claes S, Bellemans J (2013) Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc 21:2325–2330. https://doi.org/10.1007/s00167-013-2481-4
doi: 10.1007/s00167-013-2481-4 pubmed: 23552665
Waterson HB, Clement ND, Eyres KS, Mandalia VI, Toms AD (2016) The early outcome of kinematic versus mechanical alignment in total knee arthroplasty: a prospective randomised control trial. Bone Joint J 98-B:1360–1368. https://doi.org/10.1302/0301-620X.98B10.36862
doi: 10.1302/0301-620X.98B10.36862
Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ (2005) The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech 38:349–355. https://doi.org/10.1016/j.jbiomech.2004.02.024
doi: 10.1016/j.jbiomech.2004.02.024
Woon JTK, Zeng ISL, Calliess T, Windhagen H, Ettinger M, Waterson HB, Toms AD, Young SW (2018) Outcome of kinematic alignment using patient-specific instrumentation versus mechanical alignment in TKA: a meta-analysis and subgroup analysis of randomised trials. Arch Orthop Trauma Surg 138:1293–1303. https://doi.org/10.1007/s00402-018-2988-8
doi: 10.1007/s00402-018-2988-8
Yeo J‑H, Seon J‑K, Lee D‑H, Song E‑K (2019) No difference in outcomes and gait analysis between mechanical and kinematic knee alignment methods using robotic total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 27:1142–1147. https://doi.org/10.1007/s00167-018-5133-x
doi: 10.1007/s00167-018-5133-x pubmed: 30220048
Young SW, Walker ML, Bayan A, Briant-Evans T, Pavlou P, Farrington B (2017) The Chitranjan S. Ranawat award: no difference in 2‑year functional outcomes using kinematic versus mechanical alignment in TKA: a randomized controlled clinical trial. Clin Orthop Relat Res 475:9–20. https://doi.org/10.1007/s11999-016-4844-x
doi: 10.1007/s11999-016-4844-x
Zampogna B, Vasta S, Amendola A, Uribe-Echevarria Marbach B, Gao Y, Papalia R, Denaro V (2015) Assessing lower limb alignment: comparison of standard knee Xray vs long leg view. Iowa Orthop J 35:49–54
pubmed: 26361444 pmcid: 4492139

Auteurs

L-R Tuecking (LR)

Department für Endoprothetik, Diakovere Annastift, Orthopädische Klinik der Medizinischen Hochschule Hannover, Anna-von-Borries-Str. 1-6, 30625, Hannover, Germany. lars-rene.tuecking@diakovere.de.

P Savov (P)

Department für Endoprothetik, Diakovere Annastift, Orthopädische Klinik der Medizinischen Hochschule Hannover, Anna-von-Borries-Str. 1-6, 30625, Hannover, Germany.

H Windhagen (H)

Department für Endoprothetik, Diakovere Annastift, Orthopädische Klinik der Medizinischen Hochschule Hannover, Anna-von-Borries-Str. 1-6, 30625, Hannover, Germany.

M Ettinger (M)

Department für Endoprothetik, Diakovere Annastift, Orthopädische Klinik der Medizinischen Hochschule Hannover, Anna-von-Borries-Str. 1-6, 30625, Hannover, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH