Oscillatory potentials in patients with birdshot chorioretinopathy.
Birdshot chorioretinopathy
ERG
Fourier analysis
Oscillatory potentials
Posterior uveitis
Journal
Documenta ophthalmologica. Advances in ophthalmology
ISSN: 1573-2622
Titre abrégé: Doc Ophthalmol
Pays: Netherlands
ID NLM: 0370667
Informations de publication
Date de publication:
12 2020
12 2020
Historique:
received:
08
07
2019
accepted:
03
06
2020
pubmed:
17
6
2020
medline:
21
11
2020
entrez:
17
6
2020
Statut:
ppublish
Résumé
The electroretinogram (ERG) has proven to be useful in the evaluation and monitoring of patients with posterior uveitis. ERG oscillatory potentials (OPs) are sometimes reduced in many uveitic eyes with otherwise grossly normal ERG responses. This study compares ERG parameters, including OPs, between patients with birdshot chorioretinopathy, other posterior uveitis, and controls. This was a retrospective case-control study. Sixty-four patients seen at a clinical practice had a total of 93 visits during which ERG was performed on both eyes. ERG data from 93 age-matched controls were also collected. Root-mean-squared (RMS) energy of the OPs was calculated using Fourier analysis for 88 patients and 88 age-matched controls for whom complete data were available. Photopic flicker amplitudes, photopic flicker latencies, scotopic b-wave amplitudes, and OP RMS values were compared between patients and controls. Diagnostic performance was assessed using receiver operating characteristic (ROC) curves. The mean ages of patients and controls were 55.9 ± 10.8 (SD) years and 55.1 ± 11.5, respectively. 83% of the patients had a diagnosis of BCR. The mean OP RMS value was significantly different in patients (15.6 µV ± 9.7 µV) versus control eyes (33.0 µV ± 12.7 µV), p < 0.001. Area under the ROC curves (AUROC) was 0.75 for photopic flicker amplitudes, 0.77 for photopic flicker latencies, 0.72 for scotopic b-wave amplitudes, and 0.88 for OP RMS. AUROC was significantly different between OP RMS and photopic flicker amplitudes (p < 0.001), between OP RMS and flicker latencies (p = 0.0032), and between OP RMS and scotopic b-wave amplitudes (p < 0.0001). Analysis of OPs shows greater sensitivity and specificity in the diagnosis and evaluation of patients with birdshot chorioretinopathy than photopic and scotopic ERG amplitudes and photopic flicker latencies.
Identifiants
pubmed: 32542469
doi: 10.1007/s10633-020-09776-x
pii: 10.1007/s10633-020-09776-x
doi:
Types de publication
Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM