Effect of echoendoscope angle on success of guidewire manipulation during endoscopic ultrasound-guided hepaticogastrostomy.
Journal
Endoscopy
ISSN: 1438-8812
Titre abrégé: Endoscopy
Pays: Germany
ID NLM: 0215166
Informations de publication
Date de publication:
04 2021
04 2021
Historique:
aheadofprint:
15
06
2020
pubmed:
17
6
2020
medline:
27
4
2021
entrez:
17
6
2020
Statut:
ppublish
Résumé
With endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), guidewire manipulation might be a critically limiting step for nonexperts. However, the causes of difficult guidewire manipulation remain unclear. The aim of this study was to evaluate factors associated with successful guidewire manipulation. This retrospective cohort study included consecutive patients who underwent EUS-HGS between October 2018 and October 2019. We measured scope angle between the long and needle axes of the echoendoscope using still fluoroscopic imaging immediately after puncturing the intrahepatic bile duct. Factors associated with successful guidewire insertion were assessed by multivariable analysis using logistic regression. The influence of the angle between the fine-needle aspiration (FNA) needle and echoendoscope on failed guidewire insertion was assessed using receiver operating characteristic (ROC) curves. Area under the ROC curve was 0.86 (95 % confidence interval [CI] 0.00 - 0.76), and an angle of 135° offered 88.0 % sensitivity and 82.9 % specificity for predicting successful guidewire insertion. According to multivariable analysis, only angle between the FNA needle and echoendoscope > 135° was independently associated with successful guidewire insertion (odd ratio 0.03, 95 %CI 0.01 - 0.14; The angle between the FNA needle and echoendoscope might be associated with successful guidewire manipulation during EUS-HGS. Adjusting this angle to 135° before puncturing the intrahepatic bile duct might be helpful in achieving successful guidewire manipulation during EUS-HGS.
Sections du résumé
BACKGROUND
With endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), guidewire manipulation might be a critically limiting step for nonexperts. However, the causes of difficult guidewire manipulation remain unclear. The aim of this study was to evaluate factors associated with successful guidewire manipulation.
METHODS
This retrospective cohort study included consecutive patients who underwent EUS-HGS between October 2018 and October 2019. We measured scope angle between the long and needle axes of the echoendoscope using still fluoroscopic imaging immediately after puncturing the intrahepatic bile duct. Factors associated with successful guidewire insertion were assessed by multivariable analysis using logistic regression.
RESULT
The influence of the angle between the fine-needle aspiration (FNA) needle and echoendoscope on failed guidewire insertion was assessed using receiver operating characteristic (ROC) curves. Area under the ROC curve was 0.86 (95 % confidence interval [CI] 0.00 - 0.76), and an angle of 135° offered 88.0 % sensitivity and 82.9 % specificity for predicting successful guidewire insertion. According to multivariable analysis, only angle between the FNA needle and echoendoscope > 135° was independently associated with successful guidewire insertion (odd ratio 0.03, 95 %CI 0.01 - 0.14;
CONCLUSION
The angle between the FNA needle and echoendoscope might be associated with successful guidewire manipulation during EUS-HGS. Adjusting this angle to 135° before puncturing the intrahepatic bile duct might be helpful in achieving successful guidewire manipulation during EUS-HGS.
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
369-375Informations de copyright
Thieme. All rights reserved.