Effect of echoendoscope angle on success of guidewire manipulation during endoscopic ultrasound-guided hepaticogastrostomy.


Journal

Endoscopy
ISSN: 1438-8812
Titre abrégé: Endoscopy
Pays: Germany
ID NLM: 0215166

Informations de publication

Date de publication:
04 2021
Historique:
aheadofprint: 15 06 2020
pubmed: 17 6 2020
medline: 27 4 2021
entrez: 17 6 2020
Statut: ppublish

Résumé

With endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), guidewire manipulation might be a critically limiting step for nonexperts. However, the causes of difficult guidewire manipulation remain unclear. The aim of this study was to evaluate factors associated with successful guidewire manipulation. This retrospective cohort study included consecutive patients who underwent EUS-HGS between October 2018 and October 2019. We measured scope angle between the long and needle axes of the echoendoscope using still fluoroscopic imaging immediately after puncturing the intrahepatic bile duct. Factors associated with successful guidewire insertion were assessed by multivariable analysis using logistic regression. The influence of the angle between the fine-needle aspiration (FNA) needle and echoendoscope on failed guidewire insertion was assessed using receiver operating characteristic (ROC) curves. Area under the ROC curve was 0.86 (95 % confidence interval [CI] 0.00 - 0.76), and an angle of 135° offered 88.0 % sensitivity and 82.9 % specificity for predicting successful guidewire insertion. According to multivariable analysis, only angle between the FNA needle and echoendoscope > 135° was independently associated with successful guidewire insertion (odd ratio 0.03, 95 %CI 0.01 - 0.14; The angle between the FNA needle and echoendoscope might be associated with successful guidewire manipulation during EUS-HGS. Adjusting this angle to 135° before puncturing the intrahepatic bile duct might be helpful in achieving successful guidewire manipulation during EUS-HGS.

Sections du résumé

BACKGROUND
With endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), guidewire manipulation might be a critically limiting step for nonexperts. However, the causes of difficult guidewire manipulation remain unclear. The aim of this study was to evaluate factors associated with successful guidewire manipulation.
METHODS
This retrospective cohort study included consecutive patients who underwent EUS-HGS between October 2018 and October 2019. We measured scope angle between the long and needle axes of the echoendoscope using still fluoroscopic imaging immediately after puncturing the intrahepatic bile duct. Factors associated with successful guidewire insertion were assessed by multivariable analysis using logistic regression.
RESULT
The influence of the angle between the fine-needle aspiration (FNA) needle and echoendoscope on failed guidewire insertion was assessed using receiver operating characteristic (ROC) curves. Area under the ROC curve was 0.86 (95 % confidence interval [CI] 0.00 - 0.76), and an angle of 135° offered 88.0 % sensitivity and 82.9 % specificity for predicting successful guidewire insertion. According to multivariable analysis, only angle between the FNA needle and echoendoscope > 135° was independently associated with successful guidewire insertion (odd ratio 0.03, 95 %CI 0.01 - 0.14;
CONCLUSION
The angle between the FNA needle and echoendoscope might be associated with successful guidewire manipulation during EUS-HGS. Adjusting this angle to 135° before puncturing the intrahepatic bile duct might be helpful in achieving successful guidewire manipulation during EUS-HGS.

Identifiants

pubmed: 32542635
doi: 10.1055/a-1199-5418
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

369-375

Informations de copyright

Thieme. All rights reserved.

Déclaration de conflit d'intérêts

The authors declare that they have no conflicts of interest.

Auteurs

Takeshi Ogura (T)

2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan.

Nobu Nishioka (N)

2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan.

Saori Ueno (S)

2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan.

Tadahiro Yamada (T)

2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan.

Masanori Yamada (M)

2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan.

Akira Imoto (A)

2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan.

Akitoshi Hakoda (A)

2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan.

Kazuhide Higuchi (K)

2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH