Electron Ionization Mass Spectrometry for Both Liquid and Gas Chromatography in One System without the Need for Hardware Adjustments.

GC-MS GC-MS and LC-MS in one MS system LC-MS cold EI electron ionization electron ionization LC-MS supersonic molecular beams

Journal

Journal of the American Society for Mass Spectrometry
ISSN: 1879-1123
Titre abrégé: J Am Soc Mass Spectrom
Pays: United States
ID NLM: 9010412

Informations de publication

Date de publication:
28 Jun 2020
Historique:
pubmed: 17 6 2020
medline: 17 6 2020
entrez: 17 6 2020
Statut: aheadofprint

Résumé

A new instrument that bridges the gap between gas chromatography (GC) and liquid chromatography (LC) mass spectrometry (MS) was developed. In this instrument GC-MS and electron ionization LC-MS were combined in one MS system with method based mode changing. The LC pneumatic spray formation interface to MS was mounted on top of an otherwise unused GC detector slot and was connected with a flow restriction capillary to the MS through the GC oven and into the MS transfer line, parallel to the GC capillary column. The LC output mobile phase flow is directed into a spray formation and vaporization chamber. The pneumatic spray results in fine spray droplets that are thermally vaporized at a pressure equal to or greater than ambient. A portion of the vaporized mixture is directed into the heated flow restriction capillary that connects the spray formation and vaporization chamber into the electron ionization (EI) ion source, while most of the vaporized spray is released to the atmosphere. The combined GC-MS and LC-MS system can work either with standard EI or with cold EI via interfacing the flow restriction capillary into a supersonic nozzle forming a supersonic molecular beam of a vibrationally cold sample compound. We found that EI-LC-MS with cold EI has many benefits when compared with standard EI. The EI-LC-MS interface can also serve for flow injection analysis. The performance of the combined system is demonstrated in the analysis of a few sample mixtures by both GC-MS and LC-MS analysis, sequentially without hardware adjustments.

Identifiants

pubmed: 32543199
doi: 10.1021/jasms.0c00136
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Auteurs

Svetlana Tsizin (S)

School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel.

Alexander B Fialkov (AB)

School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel.

Aviv Amirav (A)

School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel.

Classifications MeSH