The Figure-of-8 Walk Test (F8W) is a valid measure of walking skill in older adults with a mobility disability. Use of the F8W in assessing walking skill in persons with Parkinson's disease (PWP) is unknown. We examined the validity of the F8W by associations with mobility, and cognitive and physical function, and determined the ability of the F8W to discriminate the motor skill of walking in PWP from that of older adults (OA). Participants, PWP (n = 60) and OA (n = 34) performed the F8W, usual straight path walking, the Montreal Cognitive Assessment (MoCA), and the Late-Life Function and Disability Instrument (LLFDI). Among PWP, F8W time and steps related to: usual gait speed (r = -0.660, -0.650); stride time variability (r = 0.377, 0.438); cognition (r = -0.293, time only); and physical function (r = -0.532, - 0.619), all The F8W is a valid indicator of the motor skill of walking in PWP. Use of the F8W may uncover walking difficulties not identified by usual gait speed.

Sections du résumé

BACKGROUND BACKGROUND
The Figure-of-8 Walk Test (F8W) is a valid measure of walking skill in older adults with a mobility disability. Use of the F8W in assessing walking skill in persons with Parkinson's disease (PWP) is unknown.
PURPOSE OBJECTIVE
We examined the validity of the F8W by associations with mobility, and cognitive and physical function, and determined the ability of the F8W to discriminate the motor skill of walking in PWP from that of older adults (OA).
METHODS METHODS
Participants, PWP (n = 60) and OA (n = 34) performed the F8W, usual straight path walking, the Montreal Cognitive Assessment (MoCA), and the Late-Life Function and Disability Instrument (LLFDI).
RESULTS RESULTS
Among PWP, F8W time and steps related to: usual gait speed (r = -0.660, -0.650); stride time variability (r = 0.377, 0.438); cognition (r = -0.293, time only); and physical function (r = -0.532, - 0.619), all
CONCLUSION CONCLUSIONS
The F8W is a valid indicator of the motor skill of walking in PWP. Use of the F8W may uncover walking difficulties not identified by usual gait speed.

Identifiants

pubmed: 32543340
doi: 10.1080/09593985.2020.1774948
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

552-560

Auteurs

Kristin Lowry (K)

Department of Physical Therapy, Des Moines University, Des Moines, IA, USA.

Taylor Woods (T)

Department of Physical Therapy, Des Moines University, Des Moines, IA, USA.

Amanda Malone (A)

Iowa Clinic Waukee Physical Therapy, Waukee, IA, USA.

Alex Krajek (A)

University of Wisconsin Hospital, Madison, WI, USA.

Ann Smiley (A)

Department of Kinesiology, Iowa State University, Ames, IA, USA.

Jessie Van Swearingen (J)

Department of Physical Therapy, University of Pittsburgh, Pittsburgh, PA, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH