Accuracy and precision of McMaster and Mini-FLOTAC egg counting techniques using egg-spiked faeces of chickens and two different flotation fluids.
Ascarid infections
Egg recovery
Faecal egg counts
Flotation fluid
Labour time
Sensitivity
Test performance
Journal
Veterinary parasitology
ISSN: 1873-2550
Titre abrégé: Vet Parasitol
Pays: Netherlands
ID NLM: 7602745
Informations de publication
Date de publication:
Jul 2020
Jul 2020
Historique:
received:
17
01
2020
revised:
27
05
2020
accepted:
28
05
2020
pubmed:
17
6
2020
medline:
2
4
2021
entrez:
17
6
2020
Statut:
ppublish
Résumé
Faecal egg counting techniques (ECTs) are useful tools for assessing anthelmintic efficacy and selecting hosts resistant to parasite infection. McMaster (MM) is one of the most commonly used ECTs, but it suffers from low sensitivity and precision. Mini-FLOTAC (MF) has been proposed to replace MM, but so far has not been evaluated for gastro-intestinal nematode infections in chickens. This study compared sensitivity, precision, and accuracy of MM and MF with two trials using egg-spiked faecal samples ranging from 50-1250 eggs per gram of faeces (EPG). In addition, effects of two flotation fluids with different specific gravities (SG), namely salt (SG = 1.20) and sucrose solutions (SG = 1.32), on accuracy and time-spent for both ECTs were evaluated. Overall sensitivity based on the composite reads across all EPG-levels was 97.1 % for MM and 100 % for MF. MF was, however, more sensitive (P = 0.003) or tended to (P = 0.087) be more sensitive than MM at only the lowest EPG-level (i.e. 50 EPG) using one of the duplicate reads, whereas there was no significant difference at any EPG-level using composite reads. Overall average precision of MF (79.5 %) was higher (P < 0.001) than that of MM (63.4 %) across all EPG-levels. Precision of MM increased from 22 to 87 % with increasing EPG-levels from 50-1250 EPG. Corresponding precision estimates for MF ranged from 76 to 91 %. Overall recovery rate of MM (74.6 %) was significantly higher (P < 0.001) than that of MF (60.1 %). There was no significant difference in recovery rate of spiked-eggs among different EPG-levels (P = 0.833). Recovery rate of MM ranged from 64 % to 79 % across different EPG-levels, while it ranged from 54 % to 64 % with MF without an interaction between ECT and EPG-level (P = 0.701). It took more time (P < 0.001) to process (prepare and read) samples with MF than with MM using the same flotation fluid. The sugar solution tended to (P = 0.100) increase egg-recovery with both ECTs, while increasing (P < 0.001) time-spent for processing the samples. Our data collectively suggest that MM is less sensitive than MF only at around minimum detection level of MM when using unrepeated reads. We conclude that McMaster is faster, relatively more accurate but less precise than Mini-FLOTAC. The sugar solution with higher SG increases accuracy of both techniques at the expense of increased labour time.
Identifiants
pubmed: 32544762
pii: S0304-4017(20)30138-2
doi: 10.1016/j.vetpar.2020.109158
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
109158Informations de copyright
Copyright © 2020 Elsevier B.V. All rights reserved.