A 2-free-end flexor carpi radialis tendon graft for treating a complex index finger extensor tendon injury.


Journal

Acta bio-medica : Atenei Parmensis
ISSN: 2531-6745
Titre abrégé: Acta Biomed
Pays: Italy
ID NLM: 101295064

Informations de publication

Date de publication:
30 05 2020
Historique:
received: 30 03 2020
accepted: 10 04 2020
entrez: 20 6 2020
pubmed: 20 6 2020
medline: 9 3 2021
Statut: epublish

Résumé

Volar plating has increasingly become the most used technique for the treatment of unstable distal radius fractures due to the low soft-tissue disturbance and its biomechanical reliability, which allows the early mobilization of the wrist. One of the main goals of the volar locking compression plates design is to avoid those soft tissue complications historically associated to the dorsal plating. However, extensor tendon complications can not be completely excluded. The authors report the case of a patient with a complete rupture of the index finger extensor tendons after volar plate fixation of the distal radius. Due to the presence of a severe tendons retraction with a 4-centimeter gap and the neighbouring soft tissues damage, it was decided to fill the gap with a 2-free-end autograft harvested from the Flexor Carpi Radialis (FCR) tendon, using the volar surgical approach performed to remove the plate. At the 2-month follow-up, the patient showed the complete recovery of the flexion-extension movements. Even though the 2-free-end FCR tendon graft is not commonly reported for the reconstruction of extensor tendons defects, we assume it deserves to be considered as an adequate technique whenever the neighbouring tendons are critically compromised.

Sections du résumé

BACKGROUND
Volar plating has increasingly become the most used technique for the treatment of unstable distal radius fractures due to the low soft-tissue disturbance and its biomechanical reliability, which allows the early mobilization of the wrist. One of the main goals of the volar locking compression plates design is to avoid those soft tissue complications historically associated to the dorsal plating. However, extensor tendon complications can not be completely excluded.
METHOD
The authors report the case of a patient with a complete rupture of the index finger extensor tendons after volar plate fixation of the distal radius. Due to the presence of a severe tendons retraction with a 4-centimeter gap and the neighbouring soft tissues damage, it was decided to fill the gap with a 2-free-end autograft harvested from the Flexor Carpi Radialis (FCR) tendon, using the volar surgical approach performed to remove the plate.
RESULTS
At the 2-month follow-up, the patient showed the complete recovery of the flexion-extension movements.
CONCLUSIONS
Even though the 2-free-end FCR tendon graft is not commonly reported for the reconstruction of extensor tendons defects, we assume it deserves to be considered as an adequate technique whenever the neighbouring tendons are critically compromised.

Identifiants

pubmed: 32555110
doi: 10.23750/abm.v91i4-S.9475
pmc: PMC7944807
doi:

Types de publication

Case Reports Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

276-279

Références

J Plast Surg Hand Surg. 2016;50(1):1-6
pubmed: 26400762
J Am Acad Orthop Surg. 2009 Jun;17(6):369-77
pubmed: 19474446
Morphologie. 2016 Mar;100(328):12-6
pubmed: 26439769
Hand (N Y). 2014 Dec;9(4):511-5
pubmed: 25414614
Injury. 2006 Aug;37(8):691-7
pubmed: 16814787
J Hand Surg Eur Vol. 2012 Jun;37(5):407-11
pubmed: 22064731
J Hand Surg Eur Vol. 2015 Mar;40(3):276-80
pubmed: 24369363
Hand (N Y). 2014 Dec;9(4):516-21
pubmed: 25414615
J Bone Joint Surg Br. 2006 Dec;88(12):1610-2
pubmed: 17159173
Hand (N Y). 2014 Sep;9(3):364-9
pubmed: 25191169
J Hand Surg Br. 1999 Feb;24(1):46-9
pubmed: 10190604
J Hand Surg Am. 1995 May;20(3 Pt 2):S82-5
pubmed: 7642955
J Hand Surg Asian Pac Vol. 2018 Dec;23(4):520-527
pubmed: 30428809
J Orthop Trauma. 2007 May;21(5):316-22
pubmed: 17485996
J Orthop Trauma. 2015 Oct;29(10):e408-13
pubmed: 26402306

Auteurs

Giovanni Battista Colasanti (GB)

Orthopaedic and Trauma Department - Hospital Santa Maria alle Scotte - Siena. colasanti.gb@outlook.com.

Carlotta Pari (C)

Orthopaedic and Trauma Department - Hospital Santa Maria delle Croci - Ravenna. carlotta.pari@alice.it.

Agnese Puzzo (A)

Orthopaedic and Trauma Department - Hospital Santa Maria delle Croci - Ravenna. dott.puzzoagnese@gmail.com.

Stefania Paderni (S)

Orthopaedic and Trauma Department - Hospital Santa Maria delle Croci - Ravenna. stefania.paderni@gmail.com.

Claudio Goretti (C)

Orthopaedic and Trauma Department - Hospital Santa Maria delle Croci - Ravenna. claudiogoretti@libero.it.

Alberto Belluati (A)

Orthopaedic and Trauma Department - Hospital Santa Maria delle Croci - Ravenna. dr.belluati@libero.it.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH