[Comparison of Contrast Enhancement between Bolus-tracking and Test-bolus Methods on Coronary CT Angiography].

cardiac imaging techniques computed tomography angiography contrast enhancement diagnostic imaging

Journal

Nihon Hoshasen Gijutsu Gakkai zasshi
ISSN: 0369-4305
Titre abrégé: Nihon Hoshasen Gijutsu Gakkai Zasshi
Pays: Japan
ID NLM: 7505722

Informations de publication

Date de publication:
2020
Historique:
entrez: 23 6 2020
pubmed: 23 6 2020
medline: 25 9 2020
Statut: ppublish

Résumé

To compare the contrast enhancement between bolus-tracking (BT) and test-bolus (TB) methods in coronary computed tomography angiography (CCTA). We enrolled 300 patients who underwent CCTA by BT (245 mg I/kg main bolus) or TB (77.4 mg I/kg test bolus with 245 mg I/kg main bolus) methods. In group BT (n=150), scanning was started automatically 5-second after contrast enhancement exceeded a predefined threshold of 150 Hounsfield units (HU). In group TB (n=150), TB peak attenuation plus 2-second was used as a delay. We recorded the CT number in the ascending aorta and determined whether the CT number was equivalent in two groups. For the equivalence test, we adopted 70 HU as the equivalence margin. The standard deviation (SD) in the CT number and the rate of patients with an acceptable CT number were compared. We also compared total iodine dose and total dose length product (DLP). The CT number of the ascending aorta was 437.6±68.9 HU in group BT and 438.9±69.7 HU in group TB; the 95% confidence interval for the difference between the groups was from -11.6 to 20.2 HU and within the range of the equivalence margins. The SD of the CT number and the rate of patients with acceptable CT number did not differ significantly between the two groups (p=0.857 and p=0.614, respectively). Total iodine dose in group TB was significantly higher than in group BT (p<0.001), and total DLP was not statistically significant (p=0.197). The contrast enhancement between BT and TB methods in CCTA was equivalent, and the distribution was not significantly different between the two groups.

Identifiants

pubmed: 32565515
doi: 10.6009/jjrt.2020_JSRT_76.6.579
doi:

Substances chimiques

Contrast Media 0

Types de publication

Journal Article

Langues

jpn

Sous-ensembles de citation

IM

Pagination

579-585

Auteurs

Masato Yoshida (M)

Department of Radiological Technology, Tsuchiya General Hospital.

Yoriaki Matsumoto (Y)

Department of Radiological Technology, Tsuchiya General Hospital.
Department of Diagnostic Radiology, Graduate School of Biomedical and Health Sciences, Hiroshima University.

Takanori Masuda (T)

Department of Radiological Technology, Tsuchiya General Hospital.
Department of Diagnostic Radiology, Graduate School of Biomedical and Health Sciences, Hiroshima University.

Yukari Kikuhara (Y)

Department of Radiological Technology, Tsuchiya General Hospital.

Yukie Kobayashi (Y)

Department of Radiological Technology, Tsuchiya General Hospital.

Takayuki Yoshiura (T)

Department of Radiological Technology, Tsuchiya General Hospital.

Tomoyasu Sato (T)

Department of Radiology, Tsuchiya General Hospital.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH