Robust Plug-and-Play Joint Axis Estimation Using Inertial Sensors.
gyroscopes and accelerometers
inertial measurement units
joint axis identification
kinematic constraints
sensor-to-segment calibration
validation on mechanical joint
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
22 Jun 2020
22 Jun 2020
Historique:
received:
17
04
2020
revised:
29
05
2020
accepted:
16
06
2020
entrez:
26
6
2020
pubmed:
26
6
2020
medline:
26
6
2020
Statut:
epublish
Résumé
Inertial motion capture relies on accurate sensor-to-segment calibration. When two segments are connected by a hinge joint, for example in human knee or finger joints as well as in many robotic limbs, then the joint axis vector must be identified in the intrinsic sensor coordinate systems. Methods for estimating the joint axis using accelerations and angular rates of arbitrary motion have been proposed, but the user must perform sufficiently informative motion in a predefined initial time window to accomplish complete identifiability. Another drawback of state of the art methods is that the user has no way of knowing if the calibration was successful or not. To achieve plug-and-play calibration, it is therefore important that 1) sufficiently informative data can be extracted even if large portions of the data set consist of non-informative motions, and 2) the user knows when the calibration has reached a sufficient level of accuracy. In the current paper, we propose a novel method that achieves both of these goals. The method combines acceleration- and angular rate information and finds a globally optimal estimate of the joint axis. Methods for sample selection, that overcome the limitation of a dedicated initial calibration time window, are proposed. The sample selection allows estimation to be performed using only a small subset of samples from a larger data set as it deselects non-informative and redundant measurements. Finally, an uncertainty quantification method that assures validity of the estimated joint axis parameters, is proposed. Experimental validation of the method is provided using a mechanical joint performing a large range of motions. Angular errors in the order of 2 ∘ were achieved using 125-1000 selected samples. The proposed method is the first truly plug-and-play method that overcome the need for a specific calibration phase and, regardless of the user's motions, it provides an accurate estimate of the joint axis as soon as possible.
Identifiants
pubmed: 32580394
pii: s20123534
doi: 10.3390/s20123534
pmc: PMC7348773
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Swedish Research Council
ID : 2015-05054
Références
J Biomech. 2008;41(5):1029-35
pubmed: 18222459
J Neuroeng Rehabil. 2014 Apr 21;11:70
pubmed: 24746123
J Biomech. 2009 Oct 16;42(14):2330-5
pubmed: 19665712
Hum Factors. 2018 May;60(3):351-362
pubmed: 29320232
Gait Posture. 2017 Jan;51:239-246
pubmed: 27833057
Sensors (Basel). 2018 Jun 08;18(6):
pubmed: 29890667
Med Biol Eng Comput. 2010 Jan;48(1):17-25
pubmed: 19911214
Sensors (Basel). 2018 Mar 15;18(3):
pubmed: 29543747
IEEE Trans Biomed Eng. 2010 Nov;57(11):
pubmed: 20667801
J Biomech. 2007;40(12):2604-11
pubmed: 17346716
Sensors (Basel). 2019 Jan 08;19(1):
pubmed: 30626130
Biomed J. 2018 Aug;41(4):249-253
pubmed: 30348268