Introduction and evaluation of a novel multi-camera surface topography system.


Journal

Gait & posture
ISSN: 1879-2219
Titre abrégé: Gait Posture
Pays: England
ID NLM: 9416830

Informations de publication

Date de publication:
07 2020
Historique:
received: 24 01 2020
revised: 10 06 2020
accepted: 11 06 2020
pubmed: 4 7 2020
medline: 1 4 2021
entrez: 4 7 2020
Statut: ppublish

Résumé

Surface topography can be used for the evaluation of spinal deformities without any radiation. However, so far this technique is limited to posterior trunk measurements due to the use of a single posterior camera. Purpose of this study was to introduce a new multi camera surface topography system and to test its reliability and validity. The surface topograph uses a two-camera system for imaging and evaluating the subjects front and back simultaneously. Inter- and intra-rater reliability was tested on 40 human subjects by two observers. For validation human, subjects were scanned by MRI and surface-topography. For additional validation we used a phantom with an anthropomorphic body which was scanned by CT and surface topography. Inter- (0.97-0.99) and intra-rater reliability (0.81-0.98) testing revealed good and excellent results in the detection of the body surface structures and measurement of areas and volumes. CT based validation revealed good correspondence between systems in the imaging and evaluation of the phantom model (0.61-10.52 %). Results on validation of human subjects revealed good to moderate results in the detection and measurements of almost all body surface structures (1.36-13.34 %). Only measurements using jugular notch as a reference showed moderate results in validity (0.62-27.5%) testing. We have introduced a novel and innovative surface topography system that allows for simultaneous anterior and posterior trunk measurements. The results of our reliability and validity tests are satisfactory. However, in particular around the jugular notch region further improvements in the surface topography reconstruction are needed.

Sections du résumé

BACKGROUND
Surface topography can be used for the evaluation of spinal deformities without any radiation. However, so far this technique is limited to posterior trunk measurements due to the use of a single posterior camera.
RESEARCH QUESTION
Purpose of this study was to introduce a new multi camera surface topography system and to test its reliability and validity.
METHODS
The surface topograph uses a two-camera system for imaging and evaluating the subjects front and back simultaneously. Inter- and intra-rater reliability was tested on 40 human subjects by two observers. For validation human, subjects were scanned by MRI and surface-topography. For additional validation we used a phantom with an anthropomorphic body which was scanned by CT and surface topography.
RESULTS
Inter- (0.97-0.99) and intra-rater reliability (0.81-0.98) testing revealed good and excellent results in the detection of the body surface structures and measurement of areas and volumes. CT based validation revealed good correspondence between systems in the imaging and evaluation of the phantom model (0.61-10.52 %). Results on validation of human subjects revealed good to moderate results in the detection and measurements of almost all body surface structures (1.36-13.34 %). Only measurements using jugular notch as a reference showed moderate results in validity (0.62-27.5%) testing.
SIGNIFICANCE
We have introduced a novel and innovative surface topography system that allows for simultaneous anterior and posterior trunk measurements. The results of our reliability and validity tests are satisfactory. However, in particular around the jugular notch region further improvements in the surface topography reconstruction are needed.

Identifiants

pubmed: 32619923
pii: S0966-6362(20)30217-4
doi: 10.1016/j.gaitpost.2020.06.016
pii:
doi:

Types de publication

Journal Article Validation Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

367-373

Informations de copyright

Copyright © 2020 Elsevier B.V. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The „a.p.-scan “was provided by Diers International GmbH, Schlangenbad, Germany. However, this did not influence the work and neutrality of the authors.

Auteurs

R Michalik (R)

Department for Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Aachen, Germany.. Electronic address: rmichalik@ukaachen.de.

M Knod (M)

Department of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.

H Siebers (H)

Department of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.

M Gatz (M)

Department of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.

T Dirrichs (T)

Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany.

J Eschweiler (J)

Department of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.

V Quack (V)

Department of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.

M Betsch (M)

Department of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH