Cantilever Type Acceleration Sensors Made by Roll-to-Roll Slot-Die Coating.
acceleration sensor
air gap
cantilever
roll-to-roll slot-die coating
sacrificial layer
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
04 Jul 2020
04 Jul 2020
Historique:
received:
27
05
2020
revised:
02
07
2020
accepted:
02
07
2020
entrez:
9
7
2020
pubmed:
9
7
2020
medline:
9
7
2020
Statut:
epublish
Résumé
This paper presents the fabrication by means of roll-to-roll slot-die coating and characterization of air gap-based cantilever type capacitive acceleration sensors. As the mass of the sensor moves in the opposite direction of the acceleration, a capacitance change occurs. The sensor is designed to have a six layers structure with an air gap. Fabrication of the air gap and cantilever was enabled by coating and removing water-soluble PVA. The bottom electrode, the dielectric layer, and the sacrificial layer were formed using the roll-to-roll slot-die coating technique. The spacer, the top electrode, and the structural layer were formed by spin coating. Several kinds of experiments were conducted for characterization of the fabricated sensor samples. Experimental results show that accelerations of up to 3.6 g can be sensed with an average sensitivity of 0.00856 %/g.
Identifiants
pubmed: 32635459
pii: s20133748
doi: 10.3390/s20133748
pmc: PMC7374456
pii:
doi:
Types de publication
Letter
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Ministry of Education of Korea
ID : 2018R1D1A1B07047744
Références
ACS Appl Mater Interfaces. 2018 Dec 5;10(48):41570-41577
pubmed: 30398330
Sci Rep. 2018 Oct 11;8(1):15167
pubmed: 30310117
Sensors (Basel). 2015 Mar 17;15(3):6441-68
pubmed: 25808763
Polymers (Basel). 2019 Feb 02;11(2):
pubmed: 30960229
Sensors (Basel). 2016 Sep 26;16(10):
pubmed: 27681734
Adv Sci (Weinh). 2019 Jan 28;6(7):1802094
pubmed: 30989030
Micromachines (Basel). 2018 Nov 16;9(11):
pubmed: 30453536
Micromachines (Basel). 2019 Feb 25;10(2):
pubmed: 30823622
Biomed Microdevices. 2007 Dec;9(6):815-21
pubmed: 17564840
Micromachines (Basel). 2018 Mar 09;9(3):
pubmed: 30424054
Materials (Basel). 2020 Feb 04;13(3):
pubmed: 32033206
Nanoscale. 2016 Jan 7;8(1):318-26
pubmed: 26611256
Adv Mater. 2020 Jan;32(3):e1805864
pubmed: 30941808
Micromachines (Basel). 2018 Jun 29;9(7):
pubmed: 30424262
Sci Rep. 2016 Sep 28;6:34322
pubmed: 27677410
Sensors (Basel). 2018 Jan 15;18(1):
pubmed: 29342966