A systematic review of occupational radiation individual dose monitoring among healthcare workers exposed in Africa.
Africa
diagnostic radiology
diagnostic x-ray
dose monitoring
healthcare workers
medical imaging
occupational radiation exposure
Journal
Journal of radiological protection : official journal of the Society for Radiological Protection
ISSN: 1361-6498
Titre abrégé: J Radiol Prot
Pays: England
ID NLM: 8809257
Informations de publication
Date de publication:
20 Nov 2020
20 Nov 2020
Historique:
received:
25
03
2020
accepted:
08
07
2020
pubmed:
9
7
2020
medline:
1
4
2022
entrez:
9
7
2020
Statut:
epublish
Résumé
Dosimetric monitoring is useful to limit exposures to ionising radiation in medical occupational settings, and reduce subsequent health risks. Scientific literatures, such as the UNSCEAR report 2017 and International Atomic Energy Agency Report 2014b, updated information on this subject; however, few African works have been found. This is the reason why we undertook this study, which summarises existing information on monitoring external radiation exposure doses for the whole body, using data from medical workers on this continent. Using standard terms and combining different keyword searches for radiation dose monitoring among radiology healthcare workers in Africa, from the titles, abstracts, and full texts, we found 3139 articles in the PubMed/MEDLINE, Google Scholar and INIS databases. Two reviewers screened the retrieved publications based on predefined eligibility criteria to identify relevant studies, extract key information from each, and summarise the data in table form. A total of 20 potentially relevant articles were identified. Among these 20 articles, 15 reported the overall average annual effective dose. Studies included in this systematic review represent an inventory of the radiation protection of medical workers in various African countries, with a focus on the monitoring of occupational radiation exposure. The size of studied populations ranged between 81 and 5152 occupational exposed workers. The mean annual effective doses ranged from 0.44 to 8.20 mSv in all specialities of medical sectors, while diagnostic radiology ranged from 0.07 to 4.37 mSv. For the nuclear medicine and radiotherapy from medical groups, the mean annual effective dose varied between 0.56 and 6.30 mSv. Industrial and research/teaching sectors data varied between 0.38 to 19.40 mSv. In conclusion, more studies implemented on dosimetric monitoring in Africa are needed to get a real picture of occupational exposure in the continent.
Identifiants
pubmed: 32640436
doi: 10.1088/1361-6498/aba402
doi:
Types de publication
Journal Article
Review
Systematic Review
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2020 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved.