Catastrophic Polyethylene Failure and Fractured Femoral Component in Modern Knee Arthroplasty Design: A Case Report.


Journal

JBJS case connector
ISSN: 2160-3251
Titre abrégé: JBJS Case Connect
Pays: United States
ID NLM: 101596828

Informations de publication

Date de publication:
Historique:
entrez: 11 7 2020
pubmed: 11 7 2020
medline: 5 2 2021
Statut: ppublish

Résumé

We report a 67-year-old gentleman who presented with a painful unstable knee. He had undergone a successful total knee arthroplasty 12 years earlier and was highly functional. He presented with a 10-month history of mild pain, instability, and gait alteration. During revision surgery, there was a loss of bony support, and a fractured femoral component was identified. He required constrained revision components for reconstruction and made an uneventful recovery. Fractured femoral components are rare complications of modern primary total knee arthroplasty. Loss of bony support in critical areas of high loading will inevitably lead to catastrophic component failure.

Identifiants

pubmed: 32649145
doi: 10.2106/JBJS.CC.19.00552
pii: 01709767-202006000-00064
doi:

Substances chimiques

Polyethylene 9002-88-4

Types de publication

Case Reports Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e19.00552

Références

Swarts E, Miller SJ, Keogh CV, Lim G, Beaver RJ. Fractured whiteside ortholoc II knee components. J Arthroplasty. 2001;16:927-34.
Whiteside LA, Fosco DR, Brooks JG Jr. Fracture of the femoral component in cementless total knee arthroplasty. Clin Orthop Relat Res. 1993;286:71-7.
Han CD, Han CW, Yang IH. Femoral component fracture due to osteolysis after cemented mobile-bearing total knee arthroplasty. J Arthroplasty. 2009;24:323.e7-12.
Huang CH, Yang CY, Cheng CK. Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty. J Arthroplasty. 1999;14:375-9.
Sarraf KM, Wharton R, Abdul-Jabar HB, Shah G, Singer GC. Fatigue fractures of total knee prostheses—a cause of knee pain. Bull Hosp Joint Dis (2013). 2014;72:242-6.
Luring C, Perlick L, Schubert T, Tingart M. A rare cause for knee pain: fracture of the femoral component after TKR. A case report. Knee Surg Sports Traumatol Arthrosc. 2007;15:756-7.
Michos J, Rallis J, Fassoulas A. Fracture of femoral component in a resurfacing total knee arthroplasty. J Arthroplasty. 2006;21:1068-71.
Duffy GP, Murray BE, Trousdale RR. Hybrid total knee arthroplasty analysis of component failures at an average of 15 years. J Arthroplasty. 2007;22:1112-5.
Lemaire R. Fatigue fracture of the femoral component in a mobile bearing knee prosthesis. Acta Orthop Belg. 2010;76:274-81.
Saito S, Tokuhashi Y, Ishii T, Mori S, Hosaka K, Ryu K, Suzuki G. Bilateral fatigue fracture of the femoral components in a cruciate-retaining cementless total knee prosthesis. Orthopedics. 2011;34:e688-91.
Edwards SA, Pandit HG, Ramos JL, Grover ML. Analysis of polyethylene thickness of tibial components in total knee replacement. J Bone Joint Surg Am. 2002;84:369-71.
Collier JP, Mayor MB, McNamara JL, Surprenant VA, Jensen RE. Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop Relat Res. 1991;273:232-42.
Won CH, Rohatgi S, Kraay MJ, Goldberg VM, Rimnac CM. Effect of resin type and manufacturing method on wear of polyethylene tibial components. Clin Orthop Relat Res. 2000;376:161-71.
Chakrabarty G, Vashishtha M, Leeder D. Polyethylene in knee arthroplasty: a review. J Clin Orthop Trauma. 2015;6:108-12.
Sigma Knee System. 2019. Available at: http://synthes.vo.llnwd.net/o16/LLNWMB8/US%20Mobile/Synthes%20North%20America/Product%20Support%20Materials/Brochures/DPY_Sigma_Fixed_Bearing_Brochure_0612-65-508.pdf . Accessed December 5, 2019.
Carter DR, Hayes WC. The compressive behavior of bone as a two-phase porous structure. J Bone Joint Surg Am. 1977;59:954-62.
Massin P. How does total knee replacement technique influence polyethylene wear? Orthop Traumatol Surg Res. 2017;103:S21-7.
Naudie DD, Ammeen DJ, Engh GA, Rorabeck CH. Wear and osteolysis around total knee arthroplasty. J Am Acad Orthop Surg. 2007;15:53-64.
Burnett RS, Keeney JA, Maloney WJ, Clohisy JC. Revision total knee arthroplasty for major osteolysis. Iowa Orthop J. 2009;29:28-37.
Berend ME, Ritter MA, Hyldahl HC, Meding JB, Redelman R. Implant migration and failure in total knee arthroplasty is related to body mass index and tibial component size. J Arthroplasty. 2008;23:104-9.
Heinlein B, Kutzner I, Graichen F, Bender A, Rohlmann A, Halder AM, Beier A, Bergmann G. ESB Clinical Biomechanics Award 2008: complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months. Clin Biomech (Bristol, Avon). 2009;24:315-26.

Auteurs

Hosam E Matar (HE)

Sunnybrook Holland Centre, University of Toronto, Toronto, Canada.

Hugh U Cameron (HU)

Holland Orthopaedic & Arthritic Centre, Sunnybrook Health Sciences, Toronto, Canada.

Jeffrey D Gollish (JD)

Holland Orthopaedic & Arthritic Centre, Sunnybrook Health Sciences, Toronto, Canada.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH