Effect of manual, preloaded, and automated preloaded injectors on corneal incision architecture after IOL implantation.
Journal
Journal of cataract and refractive surgery
ISSN: 1873-4502
Titre abrégé: J Cataract Refract Surg
Pays: United States
ID NLM: 8604171
Informations de publication
Date de publication:
Oct 2020
Oct 2020
Historique:
pubmed:
11
7
2020
medline:
13
7
2021
entrez:
11
7
2020
Statut:
ppublish
Résumé
To analyze the effects on corneal morphology of manual, preloaded, and automated preloaded intraocular lens (IOL) injectors in eye bank human corneas by environmental scanning electron microscopy (ESEM) and in patients after phacoemulsification using anterior segment optical coherence tomography (AS-OCT). Eye Clinic, Careggi University Hospital, Florence, Italy. Retrospective and experimental study. Seventy-eight corneal incisions were examined after IOL implantation: 30 in human corneas mounted on an artificial chamber using ESEM (ex vivo); 48 in patients undergoing phacoemulsification (in vivo). Three different injectors were used for both analyses: manual (Monarch III, n = 26), manual preloaded (UltraSert, n = 26), and automated preloaded system (AutonoMe, n = 26). Thirty IOLs were implanted in the ex vivo study: 5 intermediate and 5 high dioptric powers for AcrySof IQ (Monarch and UltraSert) and for Clareon (AutonoMe) IOLs. In the in vivo analysis, 16 corneal wounds for each injector were evaluated using AS-OCT; in the ex vivo study, incision width was measured and Descemet membrane detachment, posterior wound retraction, and posterior gape were analyzed. In the eye bank corneas, the incision width was significantly wider in the high dioptric power IOL manual subgroup (P < .05), with more Descemet tearing compared with AutonoMe. In the in vivo study, the incidence of Descemet membrane detachment, posterior gape, and wound retraction was lower in the automated preloaded group at 1 postoperative day 1. The automated preloaded injector ensured less trauma to the wound and contributed to preserving the endothelial side of the incision even during the implantation of high-power IOLs and in the early postoperative period.
Identifiants
pubmed: 32649432
doi: 10.1097/j.jcrs.0000000000000295
pii: 02158034-202010000-00008
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1374-1380Références
Mencucci R, Favuzza E, Salvatici MC, Spadea L, Allen D. Corneal incision architecture after IOL implantation with three different injectors: an environmental scanning electron microscopy study. Int Ophthalmol 2019;39:397–403
Khokhar S, Sharma R, Patil B, Aron N, Gupta S. Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study. Eye 2014;28:1174–1178
Berdahl JP, DeStafeno JJ, Kim T. Corneal wound architecture and integrity after phacoemulsification: evaluation of coaxial, microincision coaxial, and microincision bimanual techniques. J Cataract Refract Surg 2007;33:510–515
Jun B, Berdahl JP, Kuo AN, Cummings TJ, Kim T. Corneal wound architecture and integrity after torsional and mixed phacoemulsification: evaluation of standard and microincisional coaxial techniques. Ophthalmic Surg Lasers Imaging 2010;41:128–134
Ouchi M. Effect of intraocular lens insertion speed on surgical wound structure. J Cataract Refract Surg 2010;38:1771–1776
Weikert MP, Wang L, Barrish J, Dimalanta R, Koch DD. Quantitative measurement of wound architecture in microincision cataract surgery. J Cataract Refract Surg 2012;38:1460–1466
Bang JW, Lee JH, Kim JH, Lee DH. Structural analysis of different incision sizes and stromal hydration in cataract surgery using anterior segment optical coherence tomography. Korean J Ophthalmol 2015;29:23–30
Nanavaty MA, Kubrak-Kisza M. Evaluation of preloaded intraocular lens injection systems: ex vivo study. J Cataract Refract Surg 2017;43:558–563
Chung B, Lee H, Choi M, Seo KY, Kim EK, Kim TI. Preloaded and non-preloaded intraocular lery system and characteristics: human and porcine eyes trial. Int J Ophthalmol 2018;11:6–11
Stokes DJ. Investigating biological ultrastructure using environmental scanning electron microscopy (ESEM). In: Méndez-Vilas A, ed. Science, Technology and Education of Microscopy: An Overview. Badajoz, Spain: Formatex; 2003:564–570
Sammons R, Marquis P. Application of the low vacuum scanning electron microscope to the study of biomaterials and mammalian cells. Biomaterials 1997;18:81–86
Weikert MP, Wang L, Barrish J, Dimalanta R, Koch DD. Quantitative measurement of wound architecture in microincision cataract surgery. J Cataract Refract Surg 2012;38:1460–1466
Wang L, Dixit L, Weikert MP, Jenkins RB, Koch DD. Healing changes in clear corneal cataract incisions evaluated using Fourier-domain optical coherence tomography. J Cataract Refract Surg 2012;38:660–665
Kohnen T, Klaproth OK. Incision sizes before and after implantation of SN60WF intraocular lenses using the Monarch injector system with C and D cartridges. J Cataract Refract Surg 2008;34:1748–1753
Mamalis N. Incision width after phacoemulsification with foldable intraocular lens implantation. J Cataract Refract Surg 2000;26:237–241
Allen D, Habib M, Steel D. Final incision size after implantation of a hydrophobic acrylic aspheric intraocular lens: new motorized injector versus standard manual injector. J Cataract Refract Surg 2012;38:249–255
EspirituBernardo JP Jr. Incision sizes at different stages of phacoemulsification with foldable intraocular lens implantation. J Cataract Refract Surg 2009;35:2115–2120
Jun B, Berdahl JP, Kuo AN, Cummings TJ, Kim T. Corneal wound architecture and integrity after torsional and mixed phacoemulsification: evaluation of standard and microincisional coaxial techniques. Ophthalmic Surg Lasers Imaging 2010;41:128–134
Arboleda A, Arrieta E, Aguilar MC, Sotolongo K, Nankivil D, Parel JA. Variations in intraocular lens injector dimensions and corneal incision architecture after cataract surgery. J Cataract Refract Surg 2019;45:656–661
Wang L, Wolfe P, Chernosky A, Paliwal S, Tjia K, Lane S. In vitro delivery performance assessment of a new preloaded intraocular lens delivery system. J Cataract Refract Surg 2016;42:1814–1820
Mastropasqua L, Toto L, D'Ugo E, Lanzini M, Mattei PA, Falconio G, Doronzo E, Diomede F, Trubiani O. In vivo and in vitro results of an automated preloaded delivery system for IOL implantation in cataract surgery. Int Ophthalmol 2019;26:125–134
Pathengay A, Flynn HW Jr, Isom RF, Miller D. Endophthalmitis outbreaks following cataract surgery: causative organisms, etiologies, and visual acuity outcomes. J Cataract Refract Surg 2012;38:1278–1282