Study on the lower limit of indoor humidity subject experiments on psychological responses.


Journal

Indoor air
ISSN: 1600-0668
Titre abrégé: Indoor Air
Pays: England
ID NLM: 9423515

Informations de publication

Date de publication:
01 2021
Historique:
received: 28 06 2019
revised: 03 07 2020
accepted: 03 07 2020
pubmed: 14 7 2020
medline: 1 10 2021
entrez: 14 7 2020
Statut: ppublish

Résumé

As a basis for determining the lower limit of acceptable humidity in an indoor environment, experiments were conducted for 25 subjects to assess the maximum expected sensations of dryness, discomfort based on humidity, and intolerance based on humidity, under conditions of 26°C and 10% RH. As results, distinct negative evaluations (dry, uncomfortable, or intolerable) were not obtained as the majority response; however, a small number of subjects declared distinct negative responses. In addition to the whole-body evaluation, the sensations for individual body parts were collected and found to be more intense for the eyes, nose, throat, and lips than for the other body parts. Significant differences between the genders were not found. For 8 of the subjects, similar experiments under a condition of 30% RH were conducted, and the difference between two humidity conditions was clearer for discomfort and intolerance than for dryness. The results suggest that the evaluation of the specific individuals who respond intensely, the consideration of intense responses for a specific part of the body, and the careful selection of an evaluation word for a psychological response might be effective to link this study to the determination of the lower limit of indoor humidity.

Identifiants

pubmed: 32657470
doi: 10.1111/ina.12717
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

250-263

Informations de copyright

© 2020 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Références

ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy; 2017: 7-10, 40.
Takada S, Matsushita T. Modeling of moisture evaporation from the skin, eyes and airway to evaluate sensations of dryness in low-humidity environments. J Building Phys. 2013;36(4):422-437.
Fang L, Clausen G, Fanger PO. Impact of temperature and humidity on the perception of indoor air quality. Indoor Air. 1998;8:80-90.
Toftum J, Jørgensen AS, Fanger PO. Upper limits for indoor air humidity to avoid uncomfortably humid skin. Energy Buildings. 1998;28:1-13.
Andersen I, Lundqvist GR, Jensen PL, Proctor DF. Human response to 78-hour exposure to dry air. Arch Environ Health. 1974;29:319-324.
Sunwoo Y, Chou C, Takeshita J, Murakami M, Tochihara Y. Physiological and subjective responses to low relative humidity. J Physiol Anthropol. 2006;25(1):7-14.
Wyon DP, Fang L, Lagercrantz L, Fanger PO. Experimental determination of the limiting criteria for human exposure to low winter humidity indoors. HVAC&R Res. 2006;12(2):201-213.
Tsutsumi H, Tanabe S, Harigaya J, Iguchi Y, Nakamura G. Effect of humidity on human comfort and productivity after step changes from warm and humid environment. Build Environ. 2007;42(12):4034-4042.
Kakitsuba N. Current knowledge on the effects of humidity on physiological and psychological responses. J Hum Environ Syst. 2018;20(1):1-10.
Laviana JE, Rohles FH, Bullock PE. Humidity, comfort and contact lenses. ASHRAE Trans. 1988;94(1):3-11.
Reinikainen LM, Jaakkola JJK. Significance of humidity and temperature on skin and upper airway symptoms. Indoor Air. 2003;13:344-352.
Toftum J, Jørgensen AS, Fanger PO. Upper limits of air humidity for preventing warm respiratory discomfort. Energy Buildings. 1998;28:15-23.
Gupta JK, Lin CH, Chen Q. Characterizing exhaled airflow from breathing and talking. Indoor Air. 2010;20:31-39.
Kaihara N, Takada S, Matsushita T. Transient response of skin surface moisture content to change in indoor humidity, Measurement and modeling of moisture transfer in skin surface. In Proceedings of the 5th international Building Physics Conference (IBPC); 2012:939-944.
Wolkoff P. External eye symptoms in indoor environments. Indoor Air. 2017;27:246-260.
Yoshizawa S. International study on indoor air quality and climate in office buildings, Japan Building Maintenance Association on behalf of World Federation of Building Service Contractors; 1996:1-64.

Auteurs

Satoru Takada (S)

Kobe University, Kobe, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH