Short-Term and Long-Term Variability of Intraocular Pressure Measured with an Intraocular Telemetry Sensor in Patients with Glaucoma.
24-h
IOP
continuous
glaucoma
intraocular pressure
telemetry
variability
Journal
Ophthalmology
ISSN: 1549-4713
Titre abrégé: Ophthalmology
Pays: United States
ID NLM: 7802443
Informations de publication
Date de publication:
02 2021
02 2021
Historique:
received:
30
04
2020
revised:
15
06
2020
accepted:
07
07
2020
pubmed:
15
7
2020
medline:
31
7
2021
entrez:
15
7
2020
Statut:
ppublish
Résumé
To evaluate the short-term and long-term variability of intraocular pressure (IOP) in eyes with primary open-angle glaucoma. Prospective study. Twenty-two patients previously implanted with a sulcus-based IOP sensor (EyeMate, Implandata GmbH, Germany). Twenty-two patients previously implanted with the EyeMate were requested to obtain at least 4 IOP measurements daily. Data were grouped according to the eye and the medication so that an eye treated with a particular medication was considered as one group, and the same eye treated with a different medication during the observation period was considered as a different group. A day was divided into 7 periods: night, midnight to 5:59 am; early, 6 am to 7:59 am; morning, 8 am to 10:59 am; noon, 11 am to 1:59 pm; afternoon, 2 pm to 5:59 pm; evening, 6 pm to 8:59 pm; and late, 9 pm to 11:59 pm. Short-term variability during a particular period was defined as the variability in IOP measurements obtained during that period on different days within 3 months of each other. Long-term variability was defined as the variability in IOP measurements obtained during a particular period on different days over a period of 1 year or more. Variability was assessed using intraclass correlation coefficients (ICCs). The mean age of study participants was 67.8 ± 6.8 years and 36.4% were women. The mean follow-up duration of patients was 19.2 ± 21.3 months (median, 9 months; range, 1-58 months). Overall, 92 860 IOP measurements over 15 811 measurement days were obtained and analyzed during the study period. The number of measurements obtained from each eye ranged from 1 daily to 277 daily. Intraclass correlation coefficients for short-term variability among the 7 periods during the day ranged from 0.52 (morning) to 0.66 (early). Long-term ICCs ranged from 0.29 (night) to 0.51 (late). Continual IOP monitoring showed that IOP has moderate short-term and high long-term variability in glaucoma patients. These findings demonstrate that single IOP measurements do not characterize day-to-day variations in IOP. Moreover, they show the importance of continual IOP monitoring in glaucoma patients.
Identifiants
pubmed: 32663530
pii: S0161-6420(20)30678-3
doi: 10.1016/j.ophtha.2020.07.016
pii:
doi:
Substances chimiques
Antihypertensive Agents
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
227-233Informations de copyright
Copyright © 2020 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.