A Correlative ToF-SIMS/SPM Methodology for Probing 3D Devices.


Journal

Analytical chemistry
ISSN: 1520-6882
Titre abrégé: Anal Chem
Pays: United States
ID NLM: 0370536

Informations de publication

Date de publication:
18 Aug 2020
Historique:
pubmed: 16 7 2020
medline: 16 7 2020
entrez: 16 7 2020
Statut: ppublish

Résumé

With the continuous miniaturization and increasing complexity of the devices used in nanotechnology, there is a pressing need for characterization techniques with nm-scale 3D-spatial resolution. Unfortunately, techniques like Secondary Ion Mass Spectrometry (SIMS) fail to reach the required lateral resolution. For this reason, new concepts and approaches, including the combination of different complementary techniques, have been developed in over the past years to try to overcome some of the challenges. Beyond the problem of spatial resolution in a 3D SIMS experiment, one is also faced with the impact of changes in topography during the analysis. These are quite difficult to identify because they originate from the different sputter rates of the various materials and or phases in a heterogeneous system and are notorious at the interfaces between organic and inorganic layers. As each of these materials will erode at a different velocity, accurate 3D-analysis will require means to establish a spatially resolved relation between ion bombardment time and depth. Inevitably such a nonhomogeneous erosion will lead to the development of surface topography. The impact of these effects can be overcome provided one can capture the time and spatially dependent surface erosion (velocity) with high spatial resolution during the course of a profiling experiment. Incorporating a Scanning Probe Microscope (SPM) unit which provides topography measurements with high spatial resolution, into a SIMS tool (e.g., Time of Flight (ToF) SIMS) with means to alternate between SPM and SIMS measurements, is one approach to meet that demand for complementary topographical information allowing accurate 3D chemical imaging. In this paper, the result of integrating a SPM module into a ToF-SIMS system is presented illustrating the improvements in 3D data accuracy which can be obtained when analyzing complex 3D-systems.

Identifiants

pubmed: 32664722
doi: 10.1021/acs.analchem.0c02406
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

11413-11419

Auteurs

Valentina Spampinato (V)

IMEC, Kapeldreef 75, 3001 Leuven, Belgium.

Masoud Dialameh (M)

INRIM, Strada delle Cacce 91, 10135 Turin, Italy.

Alexis Franquet (A)

IMEC, Kapeldreef 75, 3001 Leuven, Belgium.

Claudia Fleischmann (C)

IMEC, Kapeldreef 75, 3001 Leuven, Belgium.

Thierry Conard (T)

IMEC, Kapeldreef 75, 3001 Leuven, Belgium.

Paul van der Heide (P)

IMEC, Kapeldreef 75, 3001 Leuven, Belgium.

Wilfried Vandervorst (W)

IMEC, Kapeldreef 75, 3001 Leuven, Belgium.
Instituut voor Kern- en Stralingsfysica, KU Leuven, Celestijnenlaan 200D, B-3001 Leuven, Belgium.

Classifications MeSH