Radiation dose tracking in computed tomography: Red alerts and feedback. Implementing a radiation dose alert system in CT.
Computed tomography
Dose alerts
Radiation dose tracking
Radiographer feedback
Red alerts
Journal
Radiography (London, England : 1995)
ISSN: 1532-2831
Titre abrégé: Radiography (Lond)
Pays: Netherlands
ID NLM: 9604102
Informations de publication
Date de publication:
02 2021
02 2021
Historique:
received:
30
03
2020
revised:
05
06
2020
accepted:
08
06
2020
pubmed:
23
7
2020
medline:
30
9
2021
entrez:
23
7
2020
Statut:
ppublish
Résumé
This study investigates instances of elevated radiation dose on a radiation tracking system to determine their aetiologies. It aimed to investigate the impact of radiographer feedback on these alerts. Over two six-month periods 11,298 CT examinations were assessed using DoseWatch. Red alerts (dose length products twice the median) were identified and two independent reviewers established whether alerts were true (unjustifiable) or false (justifiable). During the second time period radiographers used a feedback tool to state the cause of the alert. A Chi-Square test was used to assess whether red alert incidence decreased following the implementation of radiographer feedback. There were 206 and 357 alerts during the first and second time periods, respectively. These occurred commonly with CT pulmonary angiography, brain, and body examinations. Procedural documentation errors and patient size accounted for 57% and 43% of false alerts, respectively. Radiographer feedback was provided for 17% of studies; this was not associated with a significant change in the number of alerts, but the number of true alerts declined (from 7 to 3) (χ2 = 4.14; p = 0.04). Procedural documentation errors as well as patient-related factors are associated with false alerts in DoseWatch. Implementation of a radiographer feedback tool reduced true alerts. The implementation of a radiographer feedback tool reduced the rate of true dose alerts. Low uptake with dose alert systems is an issue; the workflow needs to be considered to address this.
Identifiants
pubmed: 32693990
pii: S1078-8174(20)30092-4
doi: 10.1016/j.radi.2020.06.004
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
67-74Informations de copyright
Copyright © 2020 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Déclaration de conflit d'intérêts
Conflicts of Interest The authors declare that they have no competing interests.