B
7 T
B0
cardiac MRI
shimming
ultrahigh field
Journal
Magnetic resonance in medicine
ISSN: 1522-2594
Titre abrégé: Magn Reson Med
Pays: United States
ID NLM: 8505245
Informations de publication
Date de publication:
01 2021
01 2021
Historique:
received:
14
02
2020
revised:
19
06
2020
accepted:
22
06
2020
pubmed:
24
7
2020
medline:
11
5
2021
entrez:
24
7
2020
Statut:
ppublish
Résumé
Inhomogeneities of the static magnetic B The spatial B The strongest B Challenges in state-of-the-art B
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
182-196Informations de copyright
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.
Références
Snyder CJ, DelaBarre L, Metzger GJ, et al. Initial results of cardiac imaging at 7 Tesla. Magn Reson Med. 2009;61:517-524.
van Elderen SGC, Versluis MJ, Webb AG, et al. Initial results on in vivo human coronary MR angiography at 7 T. Magn Reson Med. 2009;62:1379-1384.
Thalhammer C, Renz W, Winter L, et al. Two-dimensional sixteen channel transmit/receive coil array for cardiac MRI at 7.0 T: Design, evaluation, and application. J Magn Reson Imaging. 2012;36:847-857.
Atalay MK, Poncelet BP, Kantor HL, Brady TJ, Weisskoff RM. Cardiac susceptibility artifacts arising from the heart-lung interface. Magn Reson Med. 2001;45:341-345.
Mattar W, Juchem C, Terekhov M, Schreiber LM. Multi-coil B0 shimming of the human heart: A theoretical assessment. In: Proceedings of the 24th Annual Meeting of ISMRM, Singapore, 2016. p 1151.
Hezel F, Thalhammer C, Waiczies S, Schulz-Menger J, Niendorf T. High spatial resolution and temporally resolved T2* mapping of normal human myocardium at 7.0 Tesla: An ultra-high field magnetic resonance feasibility study. PLoS One. 2012;7:e52324.
Schmitter S, Wu X, Ugurbil K, Van de Moortele PF. Design of parallel transmission radiofrequency pulses robust against respiration in cardiac MRI at 7 Tesla. Magn Reson Med. 2015;74:1291-1305.
Schär M, Kozerke S, Fischer SE, Boesiger P. Cardiac SSFP imaging at 3 Tesla. Magn Reson Med. 2004;51:799-806.
Nayak KS, Cunningham CH, Santos JM, Pauly JM. Real-time cardiac MRI at 3 Tesla. Magn Reson Med. 2004;51:655-660.
Ding S, Wolff SD, Epstein FH. Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI. Magn Reson Med. 1998;39:514-519.
Schmitter S, DelaBarre L, Wu X, et al. Cardiac imaging at 7 Tesla: Single- and two-spoke radiofrequency pulse design with 16-channel parallel excitation. Magn Reson Med. 2013;70:1210-1219.
Tao Y, Hess AT, Keith GA, et al. Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T. Magn Reson Med. 2015;73:1450-1456.
Ferreira PF, Gatehouse PD, Mohiaddin RH, Firmin DN. Cardiovascular magnetic resonance artefacts. J Cardiov Magn Reson. 2013;15:41.
Golay MJE. Field homogenizing coils for nuclear spin resonance instrumentation. Rev Sci Instrum. 1958;29:313-315.
Romeo F, Hoult DI. Magnet field profiling: Analysis and correcting coil design. Magn Reson Med. 1984;1:44-65.
Juchem C, Nixon TW, Diduch P, Rothman DL, Starewicz P, de Graaf RA. Dynamic shimming of the human brain at 7 T. Concepts Magn Reson B. 2010;37:116-128.
Pan JW, Lo KM, Hetherington HP. Role of very high order and degree B0 shimming for spectroscopic imaging of the human brain at 7 tesla. Magn Reson Med. 2012;68:1007-1017.
Gruetter R. Automatic, localized in vivo adjustment of all first- and second-order shim coils. Magn Reson Med. 1993;29:804-811.
Reynaud O, Gallichan D, Schaller B, Gruetter R. Fast low-specific absorption rate B0-mapping along projections at high field using two-dimensional radiofrequency pulses. Magn Reson Med. 2015;73:901-908.
Gruetter R, Boesch C. Fast, noniterative shimming of spatially localized signals. In vivo analysis of the magnetic field along axes. J Magn Reson. 1992;96:323-334.
Juchem C, Rudrapatna SU, Nixon TW, de Graaf RA. Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla. NeuroImage. 2015;105:462-472.
Juchem C. B0DETOX-B0 Detoxification Software for Magnetic Field Shimming. innovation.columbia.edu/technologies/cu17326_b0detox. 2017. Columbia Tech Venture, license CU17326. Accessed July 8, 2020.
Reeder SB, Faranesh AZ, Boxerman JL, McVeigh ER. In vivo measurement of T2* and field inhomogeneity maps in the human heart at 1.5 T. Magn Reson Med. 1998;39:988-998.
Noeske R, Seifert F, Rhein KH, Rinneberg H. Human cardiac imaging at 3 T using phased array coils. Magn Reson Med. 2000;44:978-982.
Jaffer FA, Wen H, Balaban RS, Wolff SD. A method to improve the B0 homogeneity of the heart in vivo. Magn Reson Med. 1996;36:375-383.
Schär M, Kozerke S, Boesiger P. Considerations on shimming for cardiac applications at 1.5 and 3.0 T. In: Proceedings of the 11th Annual Meeting of ISMRM, Toronto, Canada, 2003. p 174.
Suttie JJ, DelaBarre L, Pitcher A, et al. 7 Tesla (T) human cardiovascular magnetic resonance imaging using FLASH and SSFP to assess cardiac function: Validation against 1.5 T and 3 T. NMR Biomed. 2012;25:27-34.
Huelnhagen T, Paul K, Ku MC, Serradas Duarte T, Niendorf T. Myocardial T2* mapping with ultrahigh field magnetic resonance: Physics and frontier applications. Front Phys. 2017;5:1-19. Article 22.
Schär M, Vonken EJ, Stuber M. Simultaneous B0- and B1+-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T. Magn Reson Med. 2010;63:419-426.
Blamire AM, Rothman DL, Nixon T. Dynamic shim updating: A new approach towards optimized whole brain shimming. Magn Reson Med. 1996;36:159-165.
Morrell G, Spielman D. Dynamic shimming for multi-slice magnetic resonance imaging. Magn Reson Med. 1997;38:477-483.
Lohr D, Terekhov M, Kosmala A, Stefanescu MR, Hock M, Schreiber LM. Cardiac MRI with the Siemens Terra 7 T system: Initial experiences and optimization of default protocols. In: Proceedings of the 26th Annual Meeting of ISMRM, Paris, France, 2018. p 3014.
Frauenrath T, Hezel F, Renz W, et al. Acoustic cardiac triggering: A practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla. J Cardiov Magn Reson. 2010;12:67.
Hock M, Terekhov M, Lohr D, Schröder A, Walles H, Schreiber LM. B0-mapping and shimming efficiency for ex vivo MR imaging of the heart at ultra-high field-validation of standard shimming protocols of MAGNETOMTM Terra 7 T scanner. In: Proceedings of the DGMP and DGBMT Annual Meeting, Dresden, Germany, 2017. p 11.
Smith SM, Jenkinson M, Woolrich MW, et al. Advances in functional and structural MR image analysis and implementation as FSL. NeuroImage. 2004;23:S208-S219.
Hock M, Terekhov M, Lohr D, et al. Calibration of Siemens MAGNETOM™ Terra 7T shim system and analysis of static 3rd-order B0-shimming of the heart using B0DETOX. In: Proceedings of the 26th Annual Meeting of ISMRM, Paris, France, 2018. p 1752.
Juchem C, Nixon TW, McIntyre S, Rothman DL, de Graaf RA. Magnetic field modeling with a set of individual localized coils. J Magn Reson. 2010;204:281-289.
Juchem C, Herman P, Sanganahalli BG, et al. DYNAmic Multi-coIl Technique (DYNAMITE) shimming of the rat brain at 11.7 T. NMR Biomed. 2014;27:897-906.
Nassirpour S, Chang P, Fillmer A, Henning A. A comparison of optimization algorithms for localized in vivo B0 shimming. Magn Reson Med. 2018;79:1145-1156.
Hock M, Stefanescu MR, Terekhov M, et al. Third-order cardiac B0-shimming at 7 T in humans. In: Proceedings of the ISMRM Workshop on Ultrahigh Field Magnetic Resonance: Technological Advances, Translational Research Promises & Clinical Applications, Dubrovnik, Croatia, 2019. p 3.
Hock M, Terekhov M, Reiter T, Lohr D, Juchem C, Schreiber LM. Correction of myocardial B0-inhomogeneities at 7 T with ECG-gated spherical harmonics shimming. In: Proceedings of the 2019 Minnesota Workshop on High and Ultra-high Field Imaging, Center for Magnetic Resonance Research, Minneapolis, MN, 2019.
Shang Y, Theilenberg S, Mattar W, et al. High resolution simulation of B0 field conditions in the human heart based on segmented CT images. In: Proceedings of the 27th Annual Meeting of ISMRM, Montreal, Canada, 2019. p 2184.
Koch KM, McIntyre S, Nixon TW, Rothman DL, de Graaf RA. Dynamic shim updating on the human brain. J Magn Reson. 2006;180:286-296.
Attili AK, Schuster A, Nagel E, Reiber JHC, van der Geest RJ. Quantification in cardiac MRI: Advances in image acquisition and processing. Int J Cardiovasc Imaging. 2010;26:27-40.
Serradas Duarte T, Huelnhagen T, Niendorf T. Assessment of myocardial B0 over the cardiac cycle at 7.0 Tesla: Implications for susceptibility-based cardiac MR techniques. In: Proceedings of the 24th Annual Meeting of ISMRM, Singapore, 2016. p 2541.
Huelnhagen T, Hezel F, Serradas Duarte T, et al. Myocardial effective transverse relaxation time T2* correlates with left ventricular wall thickness: A 7.0 T MRI study. Magn Reson Med. 2017;77:2381-2389.
Kubach MR, Bornstedt A, Hombach V, et al. Cardiac phase-specific shimming (CPSS) for SSFP MR cine imaging at 3 T. Phys Med Biol. 2009;54:N467-N478.
Juchem C, Nixon TW, McIntyre S, Boer VO, Rothman DL, de Graaf RA. Dynamic multi-coil shimming of the human brain at 7 Tesla. J Magn Reson. 2011;212:280-288.
Stockmann JP, Witzel T, Keil B, et al. A 32-channel combined RF and B0 shim array for 3T brain imaging. Magn Reson Med. 2016;75:441-451.
Han H, Song AW, Truong TK. Integrated parallel reception, excitation, and shimming (iPRES) shim. Magn Reson Med. 2013;70:241-247.
Boer VO, vd Bank BL, van Vliet G, Luijten PR, Klomp DWJ. Direct B0 field monitoring and real-time B0 field updating in the human breast at 7 Tesla. Magn Reson Med. 2012;67:586-591.