Apnea Testing Using Continuous Positive Airway Pressure When Determining Death by Neurologic Criteria in Children: Retrospective Analysis of Potential Adverse Events.
Journal
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
ISSN: 1529-7535
Titre abrégé: Pediatr Crit Care Med
Pays: United States
ID NLM: 100954653
Informations de publication
Date de publication:
12 2020
12 2020
Historique:
pubmed:
24
7
2020
medline:
7
1
2021
entrez:
24
7
2020
Statut:
ppublish
Résumé
To determine the prevalence of adverse events during apnea testing for determination of death by neurologic criteria using continuous positive airway pressure in children. Single-center retrospective descriptive study. Academic children's hospital. Children evaluated for death by neurologic criteria in the PICU from 2013 to 2018. None. For each patient evaluated for death by neurologic criteria, we abstracted the number of apnea tests performed, vital signs and arterial blood gases during apnea testing, and outcome from the medical record. Adverse events were defined as oxygen-hemoglobin desaturation (arterial oxygen saturation < 85%), hypotension, or other significant event (e.g. arrhythmia, cardiac arrest) based on documentation in the medical record. We determined which adverse events resulted in early termination of the apnea test. We used oxygenation index, ventilator variables, and presence of vasopressors to determine preapnea test cardiopulmonary dysfunction. Seventy-two patients (age 7 yr [2.7-13.2 yr]; 48% male) underwent 121 apnea tests. Nine patients (12%) had 13 potential apnea tests deferred due to concern for cardiopulmonary instability as determined by the attending physician. Patients who underwent apnea testing had an oxygenation index of 3.5 (2.5-4.8) and were receiving vasopressors at the time of 108 apnea tests (89%). Hypotension was reported during seven apnea tests (6%) and resulted in the early termination of one apnea test (<1%). No other adverse events were reported. One hundred and twenty apnea tests (99%) were consistent with death by neurologic criteria. Apnea testing following a protocol that uses continuous positive airway pressure for apneic oxygenation has a low rate of adverse events in children meeting prerequisite criteria and determined by a pediatric intensivist to be physiologically appropriate for testing.
Identifiants
pubmed: 32701745
doi: 10.1097/PCC.0000000000002457
pii: 00130478-202012000-00040
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e1152-e1156Commentaires et corrections
Type : CommentIn
Références
Kirschen MP, Francoeur C, Murphy M, et al. Epidemiology of brain death in pediatric intensive care units in the United States. JAMA Pediatr. 2019; 173:469–476
Mathur M, Petersen L, Stadtler M, et al. Variability in pediatric brain death determination and documentation in southern California. Pediatrics. 2008; 121:988–993
Mejia RE, Pollack MM. Variability in brain death determination practices in children. JAMA. 1995; 274:550–553
Nakagawa TA, Ashwal S, Mathur M, et al.; Society of Critical Care Medicine, Section on Critical Care and Section on Neurology of American Academy of Pediatrics; Child Neurology Society. Clinical report—guidelines for the determination of brain death in infants and children: An update of the 1987 task force recommendations. Pediatrics. 2011; 128:e720–e740
Wijdicks EF, Rabinstein AA, Manno EM, et al. Pronouncing brain death: Contemporary practice and safety of the apnea test. Neurology. 2008; 71:1240–1244
Datar S, Fugate J, Rabinstein A, et al. Completing the apnea test: Decline in complications. Neurocrit Care. 2014; 21:392–396
Lévesque S, Lessard MR, Nicole PC, et al. Efficacy of a T-piece system and a continuous positive airway pressure system for apnea testing in the diagnosis of brain death. Crit Care Med. 2006; 34:2213–2216
Solek-Pastuszka J, Biernawska J, Iwańczuk W, et al. Comparison of two apnea test methods, oxygen insufflation and continuous positive airway pressure during diagnosis of brain death: Final report. Neurocrit Care. 2019; 30:348–354
Daneshmand A, Rabinstein AA, Wijdicks EFM. The apnea test in brain death determination using oxygen diffusion method remains safe. Neurology. 2019; 92:386–387
Kramer AH, Couillard P, Bader R, et al. Prevention of hypoxemia during apnea testing: A comparison of oxygen insufflation and continuous positive airway pressure. Neurocrit Care. 2017; 27:60–67
Giani M, Scaravilli V, Colombo SM, et al. Apnea test during brain death assessment in mechanically ventilated and ECMO patients. Intensive Care Med. 2016; 42:72–81
Yee AH, Mandrekar J, Rabinstein AA, et al. Predictors of apnea test failure during brain death determination. Neurocrit Care. 2010; 12:352–355
Paret G, Barzilay Z. Apnea testing in suspected brain dead children–physiological and mathematical modelling. Intensive Care Med. 1995; 21:247–252
Mayordomo-Colunga J, Rey C, Medina A, et al. Iatrogenic tension pneumothorax in children: Two case reports. J Med Case Rep. 2009; 3:7390
Goudreau JL, Wijdicks EF, Emery SF. Complications during apnea testing in the determination of brain death: Predisposing factors. Neurology. 2000; 55:1045–1048