Validation of a flow cytometry-based method to quantify viable lymphocyte subtypes in fresh and cryopreserved hematopoietic cellular products.


Journal

Cytotherapy
ISSN: 1477-2566
Titre abrégé: Cytotherapy
Pays: England
ID NLM: 100895309

Informations de publication

Date de publication:
01 2021
Historique:
received: 04 05 2020
revised: 27 05 2020
accepted: 22 06 2020
pubmed: 29 7 2020
medline: 28 7 2021
entrez: 29 7 2020
Statut: ppublish

Résumé

Adoptive cellular therapy with immune effector cells (IECs) has shown promising efficacy against some neoplastic diseases as well as potential in immune regulation. Both inherent variability in starting material and variations in cell composition produced by the manufacturing process must be thoroughly evaluated with a validated method established to quantify viable lymphocyte subtypes. Currently, commercialized immunophenotyping methods determine cell viability with significant errors in thawed products since they do not include any viability staining. We hereby report on the validation of a flow cytometry-based method for quantifying viable lymphocyte immunophenotypes in fresh and cryopreserved hematopoietic cellular products. Using fresh or frozen cellular products and stabilized blood, we report on the validation parameters accuracy, uncertainty, precision, sensitivity, robustness and contamination between samples for quantification of viable CD3+, CD4+ T cells, CD8+ T cells, CD3-CD56+CD16+/- NK cells, CD19+ B cells and CD14+ monocytes of relevance to fresh and cryopreserved hematopoietic cellular products using the Cytomics FC500 cytometer (Beckman Coulter). The acceptance criteria set in the validation plan were all met. The method is able to accommodate the variability in absolute numbers of cells in starting materials collected or cryopreserved from patients or healthy donors (uncertainty of ≤20% at three different concentrations), stability over time (compliance over 3 years during regular inter-laboratory comparisons) and confidence in meaningful changes during cell processing and manufacturing (intra-assay and intermediate precision of 10% coefficient of variation). Furthermore, the method can accurately report on the efficacy of cell depletion since the lower limit of quantification was established (CD3+, CD4+ and CD8+ cells at 9, 8 and 8 cells/µL, respectively). The method complies with Foundation for the Accreditation of Cellular Therapy (FACT) standards for IEC, FACT-Joint Accreditation Committee of ISCT-EBMT (JACIE) hematopoietic cell therapy standards, International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use Q2(R1) and International Organization for Standardization 15189 standards. Furthermore, it complies with Ligand Binding Assay Bioanalytical Focus Group/American Association of Pharmaceutical Scientists, International Council for Standardization of Hematology/International Clinical Cytometry Society and European Bioanalysis Forum recommendations for validating such methods. The implications of this effort include standardization of viable cell immunophenotyping of starting material for cell manufacturing, cell selection and in-process quality controls or dosing of IECs. This method also complies with all relevant standards, particularly FACT-JACIE standards, in terms of enumerating and reporting on the viability of the "clinically relevant cell populations."

Sections du résumé

BACKGROUND AIMS
Adoptive cellular therapy with immune effector cells (IECs) has shown promising efficacy against some neoplastic diseases as well as potential in immune regulation. Both inherent variability in starting material and variations in cell composition produced by the manufacturing process must be thoroughly evaluated with a validated method established to quantify viable lymphocyte subtypes. Currently, commercialized immunophenotyping methods determine cell viability with significant errors in thawed products since they do not include any viability staining. We hereby report on the validation of a flow cytometry-based method for quantifying viable lymphocyte immunophenotypes in fresh and cryopreserved hematopoietic cellular products.
METHODS
Using fresh or frozen cellular products and stabilized blood, we report on the validation parameters accuracy, uncertainty, precision, sensitivity, robustness and contamination between samples for quantification of viable CD3+, CD4+ T cells, CD8+ T cells, CD3-CD56+CD16+/- NK cells, CD19+ B cells and CD14+ monocytes of relevance to fresh and cryopreserved hematopoietic cellular products using the Cytomics FC500 cytometer (Beckman Coulter).
RESULTS
The acceptance criteria set in the validation plan were all met. The method is able to accommodate the variability in absolute numbers of cells in starting materials collected or cryopreserved from patients or healthy donors (uncertainty of ≤20% at three different concentrations), stability over time (compliance over 3 years during regular inter-laboratory comparisons) and confidence in meaningful changes during cell processing and manufacturing (intra-assay and intermediate precision of 10% coefficient of variation). Furthermore, the method can accurately report on the efficacy of cell depletion since the lower limit of quantification was established (CD3+, CD4+ and CD8+ cells at 9, 8 and 8 cells/µL, respectively). The method complies with Foundation for the Accreditation of Cellular Therapy (FACT) standards for IEC, FACT-Joint Accreditation Committee of ISCT-EBMT (JACIE) hematopoietic cell therapy standards, International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use Q2(R1) and International Organization for Standardization 15189 standards. Furthermore, it complies with Ligand Binding Assay Bioanalytical Focus Group/American Association of Pharmaceutical Scientists, International Council for Standardization of Hematology/International Clinical Cytometry Society and European Bioanalysis Forum recommendations for validating such methods.
CONCLUSIONS
The implications of this effort include standardization of viable cell immunophenotyping of starting material for cell manufacturing, cell selection and in-process quality controls or dosing of IECs. This method also complies with all relevant standards, particularly FACT-JACIE standards, in terms of enumerating and reporting on the viability of the "clinically relevant cell populations."

Identifiants

pubmed: 32718876
pii: S1465-3249(20)30781-7
doi: 10.1016/j.jcyt.2020.06.005
pii:
doi:

Banques de données

ClinicalTrials.gov
['NCT01853358']

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

77-87

Informations de copyright

Copyright © 2020 International Society for Cell & Gene Therapy. Published by Elsevier Inc. All rights reserved.

Auteurs

Bechara Mfarrej (B)

Centre de Thérapie Cellulaire, Institut Paoli-Calmettes, Marseille, France. Electronic address: mfarrejb@ipc.unicancer.fr.

Julie Gaude (J)

Centre de Thérapie Cellulaire, Institut Paoli-Calmettes, Marseille, France.

Jerome Couquiaud (J)

Centre de Thérapie Cellulaire, Institut Paoli-Calmettes, Marseille, France.

Boris Calmels (B)

Centre de Thérapie Cellulaire, Institut Paoli-Calmettes, Marseille, France.

Christian Chabannon (C)

Centre de Thérapie Cellulaire, Institut Paoli-Calmettes, Marseille, France.

Claude Lemarie (C)

Centre de Thérapie Cellulaire, Institut Paoli-Calmettes, Marseille, France.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs