Inducing pilon fractures in human cadaveric specimens depending on the injury mechanism: a fracture simulation.


Journal

Archives of orthopaedic and trauma surgery
ISSN: 1434-3916
Titre abrégé: Arch Orthop Trauma Surg
Pays: Germany
ID NLM: 9011043

Informations de publication

Date de publication:
May 2021
Historique:
received: 09 04 2020
accepted: 15 07 2020
pubmed: 29 7 2020
medline: 29 6 2021
entrez: 29 7 2020
Statut: ppublish

Résumé

Operative management of pilon fractures, especially high-energy compression injuries, is a challenge. Operative education is of vital importance to handle these entities. Not rarely, it is cut by economics and staff shortage. As public awareness toward operative competence rises, surgical cadaver courses that provide pre-fractured specimens can improve realism of teaching scenarios. The aim of this study is to introduce a realistic pilon fracture simulation setup regarding the injury mechanism. 8 cadaveric specimens (two left, six right) were fixed onto a custom drop-test bench in dorsiflexion (20°) and light supination (10°). The proximal part of the lower leg was potted, and the specimen was exposed to a high energetic impulse via an axial impactor. CT imaging was performed after fracture simulation to detect the exact fracture patterns and to classify the achieved fractures by two independent trauma surgeons. (AO/OTA recommendations and the Rüedi/Allgöwer). All cadaveric specimens could be successfully fractured: 6 (75%) were identified as a 43-C fracture and 2 (25%) as 43-B fracture type. Regardless of the identical mechanism two different kinds of fracture types were reported. In five cases (62.5%), the fibula was also fractured and in three specimens, a talus fracture was described. There was no statistically significant correlation found regarding Hounsfield Units (HU) and age as well as HU and required kinetic energy. A high energetic axial impulse on a fixed ankle specimen in light dorsiflexion (20°) and supination (10°) induced by a custom-made drop-test bench can successfully simulate realistic pilon fractures in cadaveric specimens with intact soft tissue envelope. Although six out of eight fractures (75%) were classified as a 43-C fracture and despite putting a lot of effort into the mechanical setup, we could not achieve an absolute level of precision. Therefore, we suggest that the injury mechanism is most likely a combination of axial loading, shear and rotation. III.

Sections du résumé

BACKGROUND BACKGROUND
Operative management of pilon fractures, especially high-energy compression injuries, is a challenge. Operative education is of vital importance to handle these entities. Not rarely, it is cut by economics and staff shortage. As public awareness toward operative competence rises, surgical cadaver courses that provide pre-fractured specimens can improve realism of teaching scenarios. The aim of this study is to introduce a realistic pilon fracture simulation setup regarding the injury mechanism.
MATERIALS AND METHODS METHODS
8 cadaveric specimens (two left, six right) were fixed onto a custom drop-test bench in dorsiflexion (20°) and light supination (10°). The proximal part of the lower leg was potted, and the specimen was exposed to a high energetic impulse via an axial impactor. CT imaging was performed after fracture simulation to detect the exact fracture patterns and to classify the achieved fractures by two independent trauma surgeons. (AO/OTA recommendations and the Rüedi/Allgöwer).
RESULTS RESULTS
All cadaveric specimens could be successfully fractured: 6 (75%) were identified as a 43-C fracture and 2 (25%) as 43-B fracture type. Regardless of the identical mechanism two different kinds of fracture types were reported. In five cases (62.5%), the fibula was also fractured and in three specimens, a talus fracture was described. There was no statistically significant correlation found regarding Hounsfield Units (HU) and age as well as HU and required kinetic energy.
CONCLUSION CONCLUSIONS
A high energetic axial impulse on a fixed ankle specimen in light dorsiflexion (20°) and supination (10°) induced by a custom-made drop-test bench can successfully simulate realistic pilon fractures in cadaveric specimens with intact soft tissue envelope. Although six out of eight fractures (75%) were classified as a 43-C fracture and despite putting a lot of effort into the mechanical setup, we could not achieve an absolute level of precision. Therefore, we suggest that the injury mechanism is most likely a combination of axial loading, shear and rotation.
LEVEL OF EVIDENCE METHODS
III.

Identifiants

pubmed: 32720001
doi: 10.1007/s00402-020-03538-9
pii: 10.1007/s00402-020-03538-9
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

837-844

Références

Atesok K, Mabrey JD, Jazrawi LM, Egol KA (2012) Surgical simulation in orthopaedic skills training. J Am Acad Orthop Sur 20(7):410–422
Blauth M, Bastian L, Krettek C, Knop C, Evans S (2001) Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques. J Orthop Trauma 15(3):153–160
doi: 10.1097/00005131-200103000-00002
Bonar SK, Marsh JL (1994) Tibial plafond fractures: changing principles of treatment. J Am Acad Orthop Surg 2:297–306
doi: 10.5435/00124635-199411000-00001
Darzi SA, Munz Y (2004) The impact of minimally invasive surgical techniques. Annu Rev Med 55:223–237
doi: 10.1146/annurev.med.55.091902.105248
Gilbody J, Prasthofer AW, Ho K, Costa ML (2011) The use and effectiveness of cadaveric workshops in higher surgical training: a systematic review. Ann R Coll Surg Engl 93(5):347–352
doi: 10.1308/147870811X582954
Holland JP, Waugh L, Horgan A, Paleri V, Deehan DJ (2011) Cadaveric hands-on training for surgical specialties: is this back to the future for surgical skills development? J Surg Educ 68(2):110–116
doi: 10.1016/j.jsurg.2010.10.002
Kuhls DA, Risucci DA, Bowyer MW, Luchette FA (2013) Advanced surgical skills for exposure in trauma: a new surgical skills cadaver course for surgery residents and fellows. J Trauma Acute Care Surg 74(2):664–670
doi: 10.1097/TA.0b013e31827d5e20
Lauge-Hansen N (1953) Fractures of the ankleV: pronation-dorsiflexion fractures. Arch Surg 67:813–820
doi: 10.1001/archsurg.1953.01260040826004
Lee S, Chung CK, Oh SH, Park SB (2013) Correlation between bone mineral density measured by dual-energy X-ray absorptiometry and Hounsfield units measured by diagnostic CT in lumbar spine. J Korean Neurosurg S 54(5):384–389
doi: 10.3340/jkns.2013.54.5.384
Martin JS, Marsh JL, Bonar SK, DeCoster TA, Found EM, Brandser EA (1997) Assessment of the AO/ASIF fracture classification for the distal tibia. J Orthop Trauma 11:477–483
doi: 10.1097/00005131-199710000-00004
Nutt J, Mehdian R, Parkin I, Dent J, Kellett C (2012) Cadaveric surgery: a novel approach to teaching clinical anatomy. Clin Teach 9(3):148–151
doi: 10.1111/j.1743-498X.2012.00536.x
Patel SP, Lee JJ, Hecht GG, Holcombe SA, Wang SC, Goulet JA (2016) Normative vertebral Hounsfield unit values and correlation with bone mineral density. J Clin Exp Orthopaed 2(114):1–7
Pellegrini CA (2006) Surgical education in the United States: navigating the white waters. Ann Surg 244(3):335–342
doi: 10.1097/01.sla.0000234800.08200.6c
Pennington DG (2006) The impact of new technology on cardiothoracic surgical practice. Ann Thorac Surg 81(1):10–18
doi: 10.1016/j.athoracsur.2005.11.031
Ruedi T, Allgower M (1969) Fractures of the lower end of the tibia into the ankle-joint. Injury 1:92
doi: 10.1016/S0020-1383(69)80066-5
Ruedi TP, Allgower M (1979) The operative treatment of intra-articular fractures of the lower end of the tibia. Clin Orthop 138:105–110
Schreiber JJ, Anderson PA, Hsu WK (2014) Use of computed tomography for assessing bone mineral density. Neurosurg Focus 37(1):E4
doi: 10.3171/2014.5.FOCUS1483
Schwindel L, Statton J, Porta D, Kress T, Robers CS (2007) Can pilon fractures be created in vitro? A biomechnical study of axial loading. OsteoTraumaCare 15:128–130
Swiontkowski MF, Sands AK, Agel J, Diab M, Schwappach JR, Kreder HJ (1997) Interobserver variation in the AO/OTA fracture classication system for pilon fractures: is there a problem? J Orthop Trauma 11:467–470
doi: 10.1097/00005131-199710000-00002
Tornetta P, Weiner L, Bergman M et al (1993) Pilon fractures: treatment with combined internal and external fixation. J Orthop Trauma 7:489–496
doi: 10.1097/00005131-199312000-00001
Wegmann K, Engel K, Burkhart KJ, Ebinger M, Holz R, Bruggemann GP, Muller LP (2014) Sequence of the Essex-Lopresti lesion—a high-speed video documentation and kinematic analysis. Acta Orthop 85(2):177–180
doi: 10.3109/17453674.2014.887952
Wegmann K, Harbrecht A, Hackl M, Uschok S, Leschinger T, Müller LP (2019) Inducing life-like distal radius fractures in human cadaveric specimens: a tool for enhanced surgical training. Arch Orthop Trauma Surg. https://doi.org/10.1007/s00402
doi: 10.1007/s00402 pubmed: 31807851
Wegmann K, Rausch V, Burkhart KJ, Hackl M, Leschinger T, Muller L (2019) Advanced surgical trauma care course—evaluation of a fracture simulation course concept with intact soft tissue. Z Orthop Unfall 158(3):291–297
doi: 10.1055/a-0983-8322

Auteurs

N Ott (N)

Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany. Nadine.Ott@uk-koeln.de.

A Harbrecht (A)

Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.

M Hackl (M)

Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.

T Leschinger (T)

Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.

J Knifka (J)

Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.

L P Müller (LP)

Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.

K Wegmann (K)

Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany. Kilian.wegmann@uk-koeln.de.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH