Augmented vertical rectus transpositions: Intraoperative measurement of torsion following sequential muscle detachment.

Eso and Exo deviations Ocular motility disorders diagnostic techniques eye movement disorders pediatric ophthalmology strabismus strabismus surgery/complications trauma

Journal

European journal of ophthalmology
ISSN: 1724-6016
Titre abrégé: Eur J Ophthalmol
Pays: United States
ID NLM: 9110772

Informations de publication

Date de publication:
Jul 2021
Historique:
pubmed: 29 7 2020
medline: 20 8 2021
entrez: 29 7 2020
Statut: ppublish

Résumé

After vertical recti transposition surgery, a torsional change may occur. We hypothesized that step-by-step monitoring of the intraoperative torsional position of the eye can avoid any unexpected complications and identify critical moments of surgery that may have adverse effects. Nine patients with sixth nerve palsy that underwent complete transposition of the superior (SR) and inferior rectus (IR) muscles to the lateral rectus muscle by means of the technique of augmented vertical recti transposition were prospectively included. The torsional position of the eye was recorded at eight stages of the procedure. We observed two distinct patterns of induced torsional deviation during partial disinsertion of a vertical rectus muscle depending on whether disinsertion began medially or laterally, after cutting about 3/4 of the muscle fibers: ¾ nasal disinsertion of the SR and ¾ temporal disinserton of the IR caused intorsion, ¾ temporal disinsertion of the SR and ¾ nasal disinsertion of the IR caused extorsion. Torsion improved after the vertical rectus was attached temporally to the sclera along the spiral of Tillaux with tying of the augmentation suture to the LR. The greatest change in torsion was from ¾ temporal disinsertion of the SR (5°extorsion), to reattachment along the spiral of Tillaux temporally (5°intorsion). The SR and IR have different torsional effects, which only appears when more than half of the fibers are detached. Augmented transposition does not cause any additional torsional effects. This intraoperative monitoring system can be used to detect unintended torsional complications, especially during transposition surgery.

Identifiants

pubmed: 32720807
doi: 10.1177/1120672120946563
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

2027-2031

Auteurs

Massimiliano Serafino (M)

Department of Neuroscience, Unit of Ophthalmology, Istituto Giannina Gaslini, Genoa, Italy.
University Eye Clinic San Giuseppe Hospital, IRCCS Multimedica, Milan, Italy.

Matteo Scaramuzzi (M)

Department of Neuroscience, Unit of Ophthalmology, Istituto Giannina Gaslini, Genoa, Italy.
University Eye Clinic San Giuseppe Hospital, IRCCS Multimedica, Milan, Italy.
Department of Clinical Science and Community Health, University of Milan, Milan, Italy.

Adriano Magli (A)

Department of Ophthalmology, Orthoptics and Pediatric Ophthalmology, University of Salerno, Salerno, Italy.

Paolo Nucci (P)

University Eye Clinic San Giuseppe Hospital, IRCCS Multimedica, Milan, Italy.
Department of Clinical Science and Community Health, University of Milan, Milan, Italy.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH