A Novel Endosurgical Prosthesis to Treat Thoracoabdominal Aortic Aneurysm in Complex Anatomy or Emergency Settings.
Journal
Aorta (Stamford, Conn.)
ISSN: 2325-4637
Titre abrégé: Aorta (Stamford)
Pays: Germany
ID NLM: 101655549
Informations de publication
Date de publication:
Apr 2020
Apr 2020
Historique:
entrez:
1
8
2020
pubmed:
1
8
2020
medline:
1
8
2020
Statut:
ppublish
Résumé
Despite improvements in operative techniques, open thoracoabdominal aortic aneurysm (TAAA) repair is complex and characterized by high mortality and morbidity rate. Less invasive techniques have been developed since 2005 for the treatment of TAAA. Unfortunately, many of these devices require custom fabrication, resulting in delay of many weeks until treatment can be delivered but crucial in critical emergency cases. We present a novel hybrid endovascular and surgical prosthesis, which was tested on five pigs, with the aim of reducing the barrier issues of endovascular therapy in such particular cases. The principal characteristic of the proposed hybrid endovascular prosthesis is to combine a proximal and distal stented zones and, in between, a classical surgical blood tied Dacron prosthesis. The device was tested in five pigs where feasibility of implantation and acute postoperative outcomes were evaluated, including bleeding, bowel ischemia, renal function, and peripheral blood perfusion. In all cases, following laparotomy, the endoprosthesis was successfully implanted under fluoroscopy and the surgical prosthesis zone could be easily detected by the radio-opaque markers. No major bleeding or cardiac events occurred throughout preparation and implantation. One hour after prosthesis implantation and surgical anastomoses of all vessels were completed, normal urine output was registered, and no acidosis was detected. This novel graft has shown ease of endoprosthesis and visceral vessels implantation without the need of thoracotomy or extracorporeal circulation and may be useful in an emergency setting or high risk and complex anatomy TAAA unsuitable for traditional endovascular aneurysm repair, or to avoid an excess waiting time for a "custom made" prosthesis. The great adaptability of this "hybrid" prosthesis in complex anatomy for the majority of TAAA could be important in high-risk patients and in some difficult situations, such as a high risk of imminent rupture.
Sections du résumé
BACKGROUND
BACKGROUND
Despite improvements in operative techniques, open thoracoabdominal aortic aneurysm (TAAA) repair is complex and characterized by high mortality and morbidity rate. Less invasive techniques have been developed since 2005 for the treatment of TAAA. Unfortunately, many of these devices require custom fabrication, resulting in delay of many weeks until treatment can be delivered but crucial in critical emergency cases. We present a novel hybrid endovascular and surgical prosthesis, which was tested on five pigs, with the aim of reducing the barrier issues of endovascular therapy in such particular cases.
METHODS
METHODS
The principal characteristic of the proposed hybrid endovascular prosthesis is to combine a proximal and distal stented zones and, in between, a classical surgical blood tied Dacron prosthesis. The device was tested in five pigs where feasibility of implantation and acute postoperative outcomes were evaluated, including bleeding, bowel ischemia, renal function, and peripheral blood perfusion.
RESULTS
RESULTS
In all cases, following laparotomy, the endoprosthesis was successfully implanted under fluoroscopy and the surgical prosthesis zone could be easily detected by the radio-opaque markers. No major bleeding or cardiac events occurred throughout preparation and implantation. One hour after prosthesis implantation and surgical anastomoses of all vessels were completed, normal urine output was registered, and no acidosis was detected.
CONCLUSIONS
CONCLUSIONS
This novel graft has shown ease of endoprosthesis and visceral vessels implantation without the need of thoracotomy or extracorporeal circulation and may be useful in an emergency setting or high risk and complex anatomy TAAA unsuitable for traditional endovascular aneurysm repair, or to avoid an excess waiting time for a "custom made" prosthesis. The great adaptability of this "hybrid" prosthesis in complex anatomy for the majority of TAAA could be important in high-risk patients and in some difficult situations, such as a high risk of imminent rupture.
Identifiants
pubmed: 32736400
doi: 10.1055/s-0040-1702143
pmc: PMC7445134
doi:
Types de publication
Journal Article
Langues
eng
Pagination
25-28Informations de copyright
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Déclaration de conflit d'intérêts
The authors declare no conflict of interest related to this article.
Références
J Thorac Cardiovasc Surg. 2015 Feb;149(2 Suppl):S134-41
pubmed: 25439781
Thorac Cardiovasc Surg. 2013 Oct;61(7):594-6
pubmed: 23585222
J Vasc Surg. 2020 Jun;71(6):1834-1842.e1
pubmed: 31708298
Ann Cardiothorac Surg. 2012 Sep;1(3):267-76
pubmed: 23977508
Ann Cardiothorac Surg. 2014 Jul;3(4):393-9
pubmed: 25133102
J Thorac Cardiovasc Surg. 2017 Feb;153(2):S32-S41.e7
pubmed: 27866781
Ann Vasc Surg. 2019 Oct 17;:
pubmed: 31629842
J Vasc Surg. 2006 Oct;44(4):688-93
pubmed: 16926086