The Accuracy of the Microsoft Kinect V2 Sensor for Human Gait Analysis. A Different Approach for Comparison with the Ground Truth.
dynamic time warping
gait analysis
kinect sensor
latency
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
07 Aug 2020
07 Aug 2020
Historique:
received:
07
07
2020
revised:
02
08
2020
accepted:
03
08
2020
entrez:
14
8
2020
pubmed:
14
8
2020
medline:
16
3
2021
Statut:
epublish
Résumé
Several studies have examined the accuracy of the Kinect V2 sensor during gait analysis. Usually the data retrieved by the Kinect V2 sensor are compared with the ground truth of certified systems using a Euclidean comparison. Due to the Kinect V2 sensor latency, the application of a uniform temporal alignment is not adequate to compare the signals. On that basis, the purpose of this study was to explore the abilities of the dynamic time warping (DTW) algorithm to compensate for sensor latency (3 samples or 90 ms) and develop a proper accuracy estimation. During the experimental stage, six iterations were performed using the a dual Kinect V2 system. The walking tests were developed at a self-selected speed. The sensor accuracy for Euclidean matching was consistent with that reported in previous studies. After latency compensation, the sensor accuracy demonstrated considerably lower error rates for all joints. This demonstrated that the accuracy was underestimated due to the use of inappropriate comparison techniques. On the contrary, DTW is a potential method that compensates for the sensor latency, and works sufficiently in comparison with certified systems.
Identifiants
pubmed: 32784586
pii: s20164405
doi: 10.3390/s20164405
pmc: PMC7472493
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Références
IEEE Trans Neural Syst Rehabil Eng. 2010 Apr;18(2):142-9
pubmed: 19497826
PLoS One. 2018 Aug 24;13(8):e0202338
pubmed: 30142631
J Biomech. 2015 Jul 16;48(10):2166-70
pubmed: 26065332
Gait Posture. 2012 May;36(1):120-6
pubmed: 22390962
Sensors (Basel). 2016 Feb 04;16(2):194
pubmed: 26861323
IEEE Trans Neural Syst Rehabil Eng. 2017 Dec;25(12):2336-2346
pubmed: 28792901
PLoS One. 2016 Nov 18;11(11):e0166532
pubmed: 27861541
J Biomech. 2018 Apr 11;71:281-285
pubmed: 29475751
PLoS One. 2009 Dec 07;4(12):e8193
pubmed: 19997606
Sensors (Basel). 2019 Apr 07;19(7):
pubmed: 30959970
Sensors (Basel). 2019 May 13;19(9):
pubmed: 31086054
J Appl Biomech. 2017 Apr;33(2):176-181
pubmed: 27918704
J Biomech. 2017 Apr 11;55:156-161
pubmed: 28285744
Clin Biomech (Bristol, Avon). 2006 Feb;21(2):175-83
pubmed: 16269207
J Med Eng Technol. 2014 Jul;38(5):274-80
pubmed: 24878252