The utility of post-biopsy ultrasonography in detecting complications after percutaneous liver biopsy in children.
Biopsy
Children
Liver
Percutaneous liver biopsy
Ultrasound
Journal
Pediatric radiology
ISSN: 1432-1998
Titre abrégé: Pediatr Radiol
Pays: Germany
ID NLM: 0365332
Informations de publication
Date de publication:
11 2020
11 2020
Historique:
received:
27
03
2020
accepted:
17
07
2020
revised:
13
06
2020
pubmed:
14
8
2020
medline:
13
7
2021
entrez:
14
8
2020
Statut:
ppublish
Résumé
Surveillance post image-guided percutaneous liver biopsy in children is variable. The aim of this study was to assess the value of 4-6-h post-procedure ultrasonography (US) in detecting post-liver-biopsy hemorrhage. This prospective study included pediatric patients who underwent US-guided percutaneous liver biopsies. All children had a US study obtained pre-procedure and one obtained 4-6 h post-procedure; US examinations were deemed positive if abnormalities were present. We also reviewed any subsequent imaging that was performed within 7 days (late imaging) at the discretion of the referring team. Changes in US findings (ΔUS) were graded by two radiologists using a descriptive non-validated scale (none, minimal, marked). Hemoglobin (Hb) levels were assessed pre-procedure and 4 h post-procedure. The diagnostic accuracy of US changes for detecting post-procedural hemorrhage was calculated based on a drop in Hb >1.5 g/dL or Hb >15% from baseline (ΔHb). We used a Kruskal-Wallis test to correlate the ΔHb with ΔUS. Association between late-imaging and post-procedure US findings was tested using a chi-square test. We included 224 biopsies. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of post-procedure US in detecting post-procedure hemorrhage ranged 26.3-42.1%, 72.4-93.3%, 0.22-0.42, and 0.87-0.88, respectively. No significant association was seen between the ΔHb and sonographic findings (P=0.068). No significant difference was seen in the need for late imaging between children who did and those who did not have positive US findings (P=0.814). The sensitivity and PPV of post-procedure US in detecting post-procedural hemorrhage are low. Our findings do not support routine post-procedure surveillance US.
Sections du résumé
BACKGROUND
Surveillance post image-guided percutaneous liver biopsy in children is variable.
OBJECTIVE
The aim of this study was to assess the value of 4-6-h post-procedure ultrasonography (US) in detecting post-liver-biopsy hemorrhage.
MATERIALS AND METHODS
This prospective study included pediatric patients who underwent US-guided percutaneous liver biopsies. All children had a US study obtained pre-procedure and one obtained 4-6 h post-procedure; US examinations were deemed positive if abnormalities were present. We also reviewed any subsequent imaging that was performed within 7 days (late imaging) at the discretion of the referring team. Changes in US findings (ΔUS) were graded by two radiologists using a descriptive non-validated scale (none, minimal, marked). Hemoglobin (Hb) levels were assessed pre-procedure and 4 h post-procedure. The diagnostic accuracy of US changes for detecting post-procedural hemorrhage was calculated based on a drop in Hb >1.5 g/dL or Hb >15% from baseline (ΔHb). We used a Kruskal-Wallis test to correlate the ΔHb with ΔUS. Association between late-imaging and post-procedure US findings was tested using a chi-square test. We included 224 biopsies.
RESULTS
The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of post-procedure US in detecting post-procedure hemorrhage ranged 26.3-42.1%, 72.4-93.3%, 0.22-0.42, and 0.87-0.88, respectively. No significant association was seen between the ΔHb and sonographic findings (P=0.068). No significant difference was seen in the need for late imaging between children who did and those who did not have positive US findings (P=0.814).
CONCLUSION
The sensitivity and PPV of post-procedure US in detecting post-procedural hemorrhage are low. Our findings do not support routine post-procedure surveillance US.
Identifiants
pubmed: 32789753
doi: 10.1007/s00247-020-04783-1
pii: 10.1007/s00247-020-04783-1
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM