Tissue "valve-over-valve" implantation in previous mechanical Bentall.
Bentall's procedure
aortic root replacement
distressing continuous valve noise
mechanical valved conduit
neo-aortic annulus
valve-over-valve
Journal
Journal of cardiac surgery
ISSN: 1540-8191
Titre abrégé: J Card Surg
Pays: United States
ID NLM: 8908809
Informations de publication
Date de publication:
Dec 2020
Dec 2020
Historique:
pubmed:
18
8
2020
medline:
15
5
2021
entrez:
18
8
2020
Statut:
ppublish
Résumé
Multiple studies have reported the adverse impact of audible clicks from mechanical heart valves on the quality of life. Sadly, this can become a lifelong liability in younger patients necessitating explantation. Bioprosthetic valve replacement is the treatment for this distressing condition associated with an isolated mechanical valve. However, patients who have undergone a mechanical Bentall's procedure represent a unique surgical challenge. In view of the significant complications associated with a redo aortic root operation, the alternative of a "valve-over-valve" implantation is an attractive option that might present reduced morbidity. We report a unique case of valve noise intolerance in a patient who underwent a bioprosthetic valve-over-valve replacement following previous Bentall's procedure with a mechanical valved conduit.
Types de publication
Case Reports
Langues
eng
Sous-ensembles de citation
IM
Pagination
3645-3647Informations de copyright
© 2020 Wiley Periodicals LLC.
Références
Ortehals K. Nearly one-quarter of patients say mechanical heart valve disturbs sleep. Cardiovasc J Afr. 2017;28(5):330.
Jassar A, Desai ND, Kobrin D, et al. Outcomes of aortic root replacement after previous aortic root replacement: the "true" re-do root. Ann Thorac Surg. 2015;99:1601-1609.
Szeto W, Bavaria JE, Bowen F, et al. Reoperative aortic root replacement in patients with previous aortic surgery. Ann Thorac Surg. 2007;84:1592-1598.
Joudinaud T, Baron F, Raffoul R, et al. Redo aortic root surgery for failure of an aortic homograft is a major technical challenge. Eur J Cardiothorac Surg. 2008;33:989-994.
Liu C, Doig F, Naidoo R, Tesar P. Redo aortic valve replacement following bio-Bentall procedure. Heart Lung Circ. 2019;28:e131-e133.
Panos A, Teoh KT, Wilson JK, Salerno TA. Replacement of the valvular prosthesis in a patient with a Bentall procedure. Ann Thorac Surg. 1992;54:555-556.
Manoly I, Krishnan M, Hoschtitzky J, Hasan R. Mechanical aortic valve-on-valve replacement in previous Bentall procedure: an alternate technique. Ann Thorac Surg. 2014;98:77-79.