[New Potential Method for Optimizing the ATCM Technique in Pediatric CT Examination].


Journal

Nihon Hoshasen Gijutsu Gakkai zasshi
ISSN: 0369-4305
Titre abrégé: Nihon Hoshasen Gijutsu Gakkai Zasshi
Pays: Japan
ID NLM: 7505722

Informations de publication

Date de publication:
2020
Historique:
entrez: 21 8 2020
pubmed: 21 8 2020
medline: 25 9 2020
Statut: ppublish

Résumé

To compare the radiation dose and image quality using the conventional method for performing the front and side scout view and a new method for performing the side scout view, and then correct the table height at the scan isocenter and perform the front scout view. We retrospectively analyzed fifty-six children who had underwent computed tomography (CT) examination between June 2014 and August 2018. We divided them into two groups. The conventional method was performed in 3 steps: 1. obtain the front scout view, 2. obtain the side scout view, and 3. main scan. Without table position correction, the new method was performed in 4 steps: 1. obtain the side scout view with table position correction, 2. patient correction at the scan isocenter, 3. obtain the front scout view, and 4. main scan. We used a 64-row CT scanner (LightSpeed VCT; GE Healthcare). Scan parameters were tube voltage 80 kV, automatic tube current modulation, noise index 16, slice thickness 5 mm, rotation time 0.4 s/rot, helical pitch 1.375, and reconstruction kernel standard. We recorded the volume dose index (CTDI Scan lengths were median (minimum-maximum) values of 16.2 cm (10.8-21.5 cm) and 16.8 cm (11.5-23.0 cm). There were no significant differences in the scan length between both groups (p=0.47). In the group with table position correction, median (minimum-maximum) values for CTDI It was suggested that the optimum image could be obtained during CT scan with automatic tube current modulation by using this potential new method (1. obtain the side scout view, 2. patient correction at the scan isocenter, 3. obtain the side scout view, and 4. main scan).

Identifiants

pubmed: 32814735
doi: 10.6009/jjrt.2020_JSRT_76.8.802
doi:

Types de publication

Journal Article

Langues

jpn

Sous-ensembles de citation

IM

Pagination

802-807

Auteurs

Takayuki Yoshiura (T)

Department of Medical Technology, Tsuchiya General Hospital.

Takanori Masuda (T)

Department of Medical Technology, Tsuchiya General Hospital.

Yoriaki Matsumoto (Y)

Department of Medical Technology, Tsuchiya General Hospital.

Tomoyasu Sato (T)

Department of Medical Technology, Tsuchiya General Hospital.

Yukari Kikuhara (Y)

Department of Medical Technology, Tsuchiya General Hospital.

Yukie Kobayashi (Y)

Department of Medical Technology, Tsuchiya General Hospital.

Tooru Ishibashi (T)

Department of Medical Technology, Tsuchiya General Hospital.

Takayuki Oku (T)

Department of Medical Technology, Tsuchiya General Hospital.

Yoshinori Funama (Y)

Department of Medical Physics, Faculty of Life Sciences, Kumamoto University.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH