Standard Versus Low-Dose Computed Tomography for Assessment of Acetabular Fracture Reduction.
Journal
Journal of orthopaedic trauma
ISSN: 1531-2291
Titre abrégé: J Orthop Trauma
Pays: United States
ID NLM: 8807705
Informations de publication
Date de publication:
09 2020
09 2020
Historique:
entrez:
21
8
2020
pubmed:
21
8
2020
medline:
29
5
2021
Statut:
ppublish
Résumé
First, to assess the impact of varying computed tomography (CT) radiation dose on surgeon assessment of postfixation acetabular fracture reduction and malpositioned implants. Second, to quantify the accuracy of CT assessments compared with the experimentally set displacement in cadaver specimens. We hypothesized that a CT dose would not affect the assessments and that CT assessments would show a high concordance with known displacement. We created posterior wall acetabular fractures in 8 fresh-frozen cadaver hips and reduced them with varying combinations of step and gap displacement. The insertion of an intra-articular screw was randomized. Each specimen had a CT with standard (120 kV), intermediate (100 kV), and low-dose (80 kV) protocols, with and without metal artifact reduction postprocessing. Reviewers quantified gap and step displacement, overall reduction, quality of the scan, and identified intra-articular implants. There were no significant differences between the CT dose protocols for assessment of gap, step, overall displacement, or the presence of intra-articular screws. Reviewers correctly categorized displacement as anatomic (0-1 mm), imperfect (2-3 mm), or poor (>3 mm) in 27.5%-57.5% of specimens. When the anatomic and imperfect categories were condensed into a single category, these scores improved to 52.5%-82.5%. Intra-articular screws were correctly identified in 56.3% of cases. Interobserver reliability was poor or moderate for all items. Reviewers rated the quality of most scans as "sufficient" (60.0%-72.5%); reviewers more frequently rated the low-dose CT as "inferior" (30.0%) and the standard dose CT as "excellent" (25%). A CT dose did not affect assessment of displacement, intra-articular screw penetration, or subjective rating of scan quality in the setting of a fixed posterior wall fracture.
Identifiants
pubmed: 32815832
doi: 10.1097/BOT.0000000000001778
pii: 00005131-202009000-00003
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
462-468Références
Borrelli J, Goldfarb C, Catalano L, et al. Assessment of articular fragment displacement in acetabular fractures: a comparison of computerized tomography and plain radiographs. J Orthop Trauma. 2002;16:449–456.
Verbeek DO, van der List JP, Villa JC, et al. Postoperative CT is superior for acetabular fracture reduction assessment and reliably predicts hip survivorship. J Bone Joint Surg. 2017;99:1745–1752.
Elnahal WA, Ward AJ, Acharya MR, et al. Does routine postoperative computerized tomography after acetabular fracture fixation affect management? J Orthop Trauma. 2019;33:S43–S48.
Verbeek DO, Van Der List JP, Moloney GB, et al. Assessing postoperative reduction after acetabular fracture surgery: a standardized digital computed tomography-based method. J Orthop Trauma. 2018;32:E284–E288.
Moed BR, Carr SEW, Gruson KI, et al. Computed tomographic assessment of fractures of the posterior wall of the acetabulum after operative treatment. J Bone Joint Surg Am. 2003;85-A:512–522.
Firoozabadi R, Hamilton B, Toogood P, et al. Risk factors for conversion to total hip arthroplasty after acetabular fractures involving the posterior wall. J Orthop Trauma. 2018;32:607–611.
Howard A, West R, Iball G, et al. An estimation of lifetime fatal carcinogenesis risk attributable to radiation exposure in the First year following polytrauma. J Bone Joint Surg. 2019;101:1375–1380.
Konda SR, Howard DO, Gyftopoulos S, et al. Computed tomography scan to detect intra-articular air in the knee joint: a cadaver study to define a low radiation dose imaging protocol. J Orthop Trauma. 2013;27:505–508.
Konda SR, Goch AM, Haglin J, et al. Ultralow-dose CT (REDUCTION protocol) for extremity fracture evaluation is as safe and effective as conventional CT: an evaluation of quality outcomes. J Orthop Trauma. 2018;32:216–222.
Mansfield C, Ali S, Komperda K, et al. Optimizing radiation dose in computed tomography of articular fractures. J Orthop Trauma. 2017;31:401–406.
Eriksson T, Berg P, Olerud C, et al. Low-dose CT of postoperative pelvic fractures: a comparison with radiography. Acta Radiol. 2019;60:85–91.
McCollough CH, Primak AN, Braun N, et al. Strategies for reducing radiation dose in CT. Radiol Clin North Am. 2009;47:27–40.
Lira D, Padole A, Kalra MK, et al. Tube potential and CT radiation dose optimization. AJR Am J Roentgenol. 2015;204:W4–W10.
Matta JM. Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury. J Bone Joint Surg Am. 1996;78:1632–1645.
Tannast M, Najibi S, Matta JM. Two to twenty-year survivorship of the hip in 810 patients with operatively treated acetabular fractures. J Bone Joint Surg Am. 2012;94:1559–1567.
Dailey SK, Phillips CT, Radley JM, et al. Achieving anatomic acetabular fracture reduction - when is the best time to operate?. J Orthop Trauma. 2016;30:426–431.
Henry PDG, Park SSH, Paterson JM, et al. Risk of hip arthroplasty after open reduction internal fixation of a fracture of the acetabulum: a matched cohort study. J Orthop Trauma. 2018;32:134–140.
Jaskolka DN, Di Primio GA, Sheikh AM, et al. CT of preoperative and postoperative acetabular fractures revisited. J Comput Assist Tomogr. 2014;38:344–347.
Archdeacon MT, Dailey SK. Efficacy of routine postoperative CT scan after open reduction and internal fixation of the acetabulum. J Orthop Trauma. 2015;29:354–358.
Huda W, Ogden KM, Khorasani MR. Converting dose-length product to effective dose at CT. Radiology. 2008;248:995–1003.
Wylie JD, Jenkins PA, Beckmann JT, et al. Computed tomography scans in patients with young adult hip pain carry a lifetime risk of malignancy. J Arthrosc Relat Surg. 2018;34:155–163.e3.
Bauhs JA, Vrieze TJ, Primak AN, et al. CT dosimetry: comparison of measurement techniques and devices. Radiographics. 2008;28:245–253.
Su AW, Hillen TJ, Eutsler EP, et al. Low-dose computed tomography reduces radiation exposure by 90% compared with traditional computed tomography among patients undergoing hip-preservation surgery. J Arthrosc Relat Surg. 2019;35:1385–1392.
Chew FS, Relyea-Chew A, Ochoa ER. Postmortem computed tomography of cadavers embalmed for use in teaching gross anatomy. J Comput Assist Tomogr. 2006;30:949–954.
Thali MJ, Yen K, Schweitzer W, et al. Virtopsy, a new imaging horizon in forensic pathology: virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI)-a feasibility study. J Forensic Sci. 2003;48:386–403.