Pressure based MRI-compatible muscle fascicle length and joint angle estimation.
MRI-compatible
Muscle state sensor
Wearable sensor
Journal
Journal of neuroengineering and rehabilitation
ISSN: 1743-0003
Titre abrégé: J Neuroeng Rehabil
Pays: England
ID NLM: 101232233
Informations de publication
Date de publication:
26 08 2020
26 08 2020
Historique:
received:
03
03
2020
accepted:
05
08
2020
entrez:
27
8
2020
pubmed:
28
8
2020
medline:
15
12
2020
Statut:
epublish
Résumé
Functional magnetic resonance imaging (fMRI) provides critical information about the neurophysiology of the central nervous systems (CNS), posing clinical significance for the understanding of neuropathologies and advancement of rehabilitation. Typical fMRI study designs include subjects performing designed motor tasks within specific time frames, in which fMRI data are then analyzed by assuming that observed functional brain activations correspond to the designed tasks. Therefore, developing MRI-compatible sensors that enable real-time monitoring of subjects' task performances would allow for highly accurate fMRI studies. While several MRI-compatible sensors have been developed, none have demonstrated the ability to measure individual muscle fascicle length during fMRI, which could help uncover the complexities of the peripheral and central nervous systems. Furthermore, previous MRI-compatible sensors have been focused on biologically intact populations, limiting accessibility to populations such as those who have undergone amputation. We propose a lightweight, low-cost, skin impedance-insensitive pressure-based muscular motion sensor (pMMS) that provides reliable estimates of muscle fascicle length and joint angle. The muscular motions are captured through measured pressure changes in an air pocket wrapped around the muscle of interest, corresponding to its muscular motion. The muscle fascicle length and joint angle are then estimated from the measured pressure changes based on the proposed muscle-skin-sensor interaction dynamics. Furthermore, we explore an integration method of multiple pMMS systems to expand the sensor capacity of estimating muscle fascicle length and joint angle. Ultrasound imaging paired with joint encoder measurements are utilized to assess pMMS estimation accuracy of muscle fascicle length in the tibialis anterior (TA) and ankle joint angle, respectively, of five biologically intact subjects. We found that a single pMMS sufficiently provides robust and accurate estimations of TA muscle fascicle length and ankle joint angle during dorsiflexion at various speeds and amplitudes. Further, differential pressure readings from two pMMSs, in which each pMMS were proximally and distally placed, were able to mitigate errors due to perturbations, expanding pMMS capacity for muscle fascicle length and ankle joint angle estimation during the full range of plantar flexion and dorsiflexion. Our results from this study demonstrate the feasibility of the pMMS system to further be incorporated in fMRI settings for real-time monitoring of subjects' task performances, allowing sophisticated fMRI study designs.
Sections du résumé
BACKGROUND
Functional magnetic resonance imaging (fMRI) provides critical information about the neurophysiology of the central nervous systems (CNS), posing clinical significance for the understanding of neuropathologies and advancement of rehabilitation. Typical fMRI study designs include subjects performing designed motor tasks within specific time frames, in which fMRI data are then analyzed by assuming that observed functional brain activations correspond to the designed tasks. Therefore, developing MRI-compatible sensors that enable real-time monitoring of subjects' task performances would allow for highly accurate fMRI studies. While several MRI-compatible sensors have been developed, none have demonstrated the ability to measure individual muscle fascicle length during fMRI, which could help uncover the complexities of the peripheral and central nervous systems. Furthermore, previous MRI-compatible sensors have been focused on biologically intact populations, limiting accessibility to populations such as those who have undergone amputation.
METHODS
We propose a lightweight, low-cost, skin impedance-insensitive pressure-based muscular motion sensor (pMMS) that provides reliable estimates of muscle fascicle length and joint angle. The muscular motions are captured through measured pressure changes in an air pocket wrapped around the muscle of interest, corresponding to its muscular motion. The muscle fascicle length and joint angle are then estimated from the measured pressure changes based on the proposed muscle-skin-sensor interaction dynamics. Furthermore, we explore an integration method of multiple pMMS systems to expand the sensor capacity of estimating muscle fascicle length and joint angle. Ultrasound imaging paired with joint encoder measurements are utilized to assess pMMS estimation accuracy of muscle fascicle length in the tibialis anterior (TA) and ankle joint angle, respectively, of five biologically intact subjects.
RESULTS
We found that a single pMMS sufficiently provides robust and accurate estimations of TA muscle fascicle length and ankle joint angle during dorsiflexion at various speeds and amplitudes. Further, differential pressure readings from two pMMSs, in which each pMMS were proximally and distally placed, were able to mitigate errors due to perturbations, expanding pMMS capacity for muscle fascicle length and ankle joint angle estimation during the full range of plantar flexion and dorsiflexion.
CONCLUSIONS
Our results from this study demonstrate the feasibility of the pMMS system to further be incorporated in fMRI settings for real-time monitoring of subjects' task performances, allowing sophisticated fMRI study designs.
Identifiants
pubmed: 32843093
doi: 10.1186/s12984-020-00745-8
pii: 10.1186/s12984-020-00745-8
pmc: PMC7449022
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
118Références
IEEE Eng Med Biol Mag. 2008 May-Jun;27(3):35-41
pubmed: 18519180
Ultrasound Med Biol. 2018 Dec;44(12):2492-2504
pubmed: 30185385
J Neurophysiol. 2000 Jan;83(1):528-36
pubmed: 10634893
J Physiol. 1996 Oct 1;496 ( Pt 1):287-97
pubmed: 8910216
Neuroimage. 2012 Aug 15;62(2):1152-6
pubmed: 21963919
Skin Res Technol. 2009 Feb;15(1):55-67
pubmed: 19152580
Biol Cybern. 1986;55(2-3):135-44
pubmed: 3801534
Physiol Rev. 2006 Jan;86(1):89-154
pubmed: 16371596
Gait Posture. 2019 Jun;71:7-13
pubmed: 30999270
IEEE Eng Med Biol Mag. 2008 May-Jun;27(3):51-8
pubmed: 18519182
Exerc Sport Sci Rev. 2014 Jul;42(3):126-35
pubmed: 24949846
Front Physiol. 2018 Apr 19;9:408
pubmed: 29725306
Skin Res Technol. 2004 May;10(2):96-103
pubmed: 15059176
Exerc Sport Sci Rev. 2000 Jul;28(3):99-107
pubmed: 10916700
IEEE Trans Haptics. 2016 Jan-Mar;9(1):20-32
pubmed: 26441454
Science. 1969 Jun 20;164(3886):1356-65
pubmed: 4181952
J Neurosci Methods. 2009 May 15;179(2):230-9
pubmed: 19428532
J Neurosci Methods. 2006 Sep 15;155(2):300-7
pubmed: 16490258