Odorant Monitoring in Natural Gas Pipelines Using Ultraviolet-Visible Spectroscopy.
Portable ultraviolet spectrophotometer
TD-DFT
THT detection
field detection
natural gas odorants
tetrahydrothiophane
time-dependent density functional theory calculations
vibronic structure
Journal
Applied spectroscopy
ISSN: 1943-3530
Titre abrégé: Appl Spectrosc
Pays: United States
ID NLM: 0372406
Informations de publication
Date de publication:
Feb 2021
Feb 2021
Historique:
pubmed:
4
9
2020
medline:
31
8
2021
entrez:
4
9
2020
Statut:
ppublish
Résumé
The remote, timely and in-field detection of sulfured additives in natural gas pipelines is a challenge for environmental, commercial and safety reasons. Moreover, the constant control of the level of odorants in a pipeline is required by law to prevent explosions and accidents. Currently, the detection of the most common odorants (THT = tetrahydrothiophane; TBM = tertiary butyl mercaptan) added to natural gas streams in pipelines is made in situ by using portable gas chromatography apparatuses. In this study, we report the analysis of the ultraviolet spectra obtained by a customized ultraviolet spectrophotometer, named Spectra, for the in-field detection of thiophane and tertiary butyl mercaptan. Spectra were conceived to accomplish the remote analysis of odorants in the pipelines of the natural gas stream through the adoption of technical solutions aimed to adapt a basic bench ultraviolet spectrophotometer to the in-field analysis of gases. The remotely controlled system acquires spectra continuously, performing the quantitative determination of odorants and catching systemic or accidental variations of the gaseous mixture in different sites of the pipeline. The analysis of the experimental spectra was carried out also through theoretical quantum mechanical approaches aimed to detect and to correctly assign the nature of the intrinsic electronic transitions of the two odorants, thiophane and tertiary butyl mercaptan, that cause the ultraviolet absorptions. So far, these theoretical aspects have never been studied before. The absorption maxima of thiophane and tertiary butyl mercaptan spectra were computationally simulated through the usage of selected molecular models with satisfactory results. The good matches between the experimental and theoretical datasets corroborate the reliability of the collected data. During the tests, unexpected pollutants and accidental malfunctions have been detected and also identified by Spectra, making this instrument suitable for many purposes.
Identifiants
pubmed: 32880187
doi: 10.1177/0003702820960737
doi:
Substances chimiques
Air Pollutants
0
Natural Gas
0
Thiophenes
0
tetrahydrothiophene
744EHT13FM
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM