A randomised clinical trial of ultrasound guided cannulation of difficult fistulae for dialysis access.
AV fistula
Ultrasound guidance
cannulation
dialysis access
nursing
ultrasonography – Doppler evaluation
Journal
The journal of vascular access
ISSN: 1724-6032
Titre abrégé: J Vasc Access
Pays: United States
ID NLM: 100940729
Informations de publication
Date de publication:
Jul 2021
Jul 2021
Historique:
pubmed:
5
9
2020
medline:
26
11
2021
entrez:
5
9
2020
Statut:
ppublish
Résumé
Arteriovenous fistulae (AVF) are preferred for dialysis access but require accurate cannulation for effective dialysis. Evidence supports improvements in cannulation and complication rates using ultrasound guidance (USG) in cannulating other sites. This mixed methods, randomised controlled trial aimed to assess effects of USG during AVF cannulation. Participants with difficult to cannulate AVF had each cannulation event randomised to USG or standard technique (no USG). The primary outcome was the incidence and number of additional needle passes. Secondary outcomes included: the incidence and number of additional skin punctures; time to achieve two needle cannulation; pain associated with cannulation; local complications. Qualitative outcomes were assessed using patient and staff questionnaires. Thirty-two participants had 346 cannulation events randomised (170 to USG and 176 to standard cannulation). USG resulted in a significant reduction in additional needle passes (72 vs 99 USG cannulation of AVF is more accurate and no more painful than non-image guided cannulation, but prolonged time to cannulation. Some of the excess time involved may be due to the trial being performed early in cannulating staff's learning curve with the USG technique. Further work to elucidate which patients gain most benefit from USG cannulation and the effect of USG on cannulation complications and AVF patency is warranted.
Sections du résumé
BACKGROUND
BACKGROUND
Arteriovenous fistulae (AVF) are preferred for dialysis access but require accurate cannulation for effective dialysis. Evidence supports improvements in cannulation and complication rates using ultrasound guidance (USG) in cannulating other sites. This mixed methods, randomised controlled trial aimed to assess effects of USG during AVF cannulation.
METHODS
METHODS
Participants with difficult to cannulate AVF had each cannulation event randomised to USG or standard technique (no USG). The primary outcome was the incidence and number of additional needle passes. Secondary outcomes included: the incidence and number of additional skin punctures; time to achieve two needle cannulation; pain associated with cannulation; local complications. Qualitative outcomes were assessed using patient and staff questionnaires.
RESULTS
RESULTS
Thirty-two participants had 346 cannulation events randomised (170 to USG and 176 to standard cannulation). USG resulted in a significant reduction in additional needle passes (72 vs 99
CONCLUSION
CONCLUSIONS
USG cannulation of AVF is more accurate and no more painful than non-image guided cannulation, but prolonged time to cannulation. Some of the excess time involved may be due to the trial being performed early in cannulating staff's learning curve with the USG technique. Further work to elucidate which patients gain most benefit from USG cannulation and the effect of USG on cannulation complications and AVF patency is warranted.