Association between indoor microbiome exposure and sick building syndrome (SBS) in junior high schools of Johor Bahru, Malaysia.
Bacteria
Fungi
Indoor microbiome
Malaysia
School
Sick building syndrome
Journal
The Science of the total environment
ISSN: 1879-1026
Titre abrégé: Sci Total Environ
Pays: Netherlands
ID NLM: 0330500
Informations de publication
Date de publication:
20 Jan 2021
20 Jan 2021
Historique:
received:
21
07
2020
revised:
20
08
2020
accepted:
21
08
2020
pubmed:
6
9
2020
medline:
20
11
2020
entrez:
5
9
2020
Statut:
ppublish
Résumé
Sick building syndrome (SBS) is a collection of nonspecific syndromes linked with the built environment. The occurrence of SBS is associated with humidity, ventilation, moulds and microbial compounds exposure. However, no study has reported the association between indoor microbiome and SBS. In this study, 308 students were surveyed for SBS symptoms from 21 classrooms of 7 junior high schools from Johor Bahru, Malaysia, and vacuum dust from floor, desks and chairs was collected. High throughput amplicon sequencing (16S rRNA gene and ITS region) and quantitative PCR were conducted to characterize the absolute concentration of bacteria and fungi taxa. In total, 326 bacterial and 255 fungal genera were detected in dust with large compositional variation among classrooms. Also, half of these samples showed low compositional similarity to microbiome data deposited in the public database. The number of observed OTUs in Gammaproteobacteria was positively associated with SBS (p = 0.004). Eight microbial genera were associated with SBS (p < 0.01). Bacterial genera, Rhodomicrobium, Scytonema and Microcoleus, were protectively (negatively) associated with ocular and throat symptoms and tiredness, and Izhakiella and an unclassified genus from Euzebyaceae were positively associated with the throat and ocular symptoms. Three fungal genera, Polychaeton, Gympopus and an unclassified genus from Microbotryaceae, were mainly positively associated with tiredness. The associations differed with our previous study in microbial compounds (endotoxin and ergosterol) and SBS in the same population, in which nasal and dermal symptoms were affected. A higher indoor relative humidity and visible dampness or mould in classrooms were associated with a higher concentration of potential risk bacteria and a lower concentration of potential protective bacteria (p < 0.01). This is the first study to characterize the SBS-associated microorganisms in the indoor environment, revealing complex interactions between microbiome, SBS symptoms and environmental characteristics.
Identifiants
pubmed: 32890872
pii: S0048-9697(20)35433-4
doi: 10.1016/j.scitotenv.2020.141904
pii:
doi:
Substances chimiques
RNA, Ribosomal, 16S
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
141904Informations de copyright
Copyright © 2020 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.