Tibiofibular Space Widening Assessment With a Ball-Tipped Probe in a Syndesmosis Injury Model.
arthroscopy
ball probe
cadaver
diagnosis
syndesmosis
Journal
The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons
ISSN: 1542-2224
Titre abrégé: J Foot Ankle Surg
Pays: United States
ID NLM: 9308427
Informations de publication
Date de publication:
Historique:
received:
07
10
2019
revised:
26
03
2020
accepted:
28
03
2020
pubmed:
8
9
2020
medline:
25
6
2021
entrez:
7
9
2020
Statut:
ppublish
Résumé
Assessment of syndesmotic instability is not precise with existing evaluation methods. This study was conducted to investigate the use of a ball-tipped probe under arthroscopy for quantitative assessment of tibiofibular space widening in a syndesmosis injury model. The test specimens were 5 uninjured ankles from Thiel-fixed cadavers of 2 male subjects and 3 female subjects of mean age of 82.4 years at death. The ball-tipped probe consisted of a metal probe having a ball at each end with diameters ranging from of 1.5 mm to 5.0 mm, in increments of 0.5 mm. The tibiofibular joint was observed arthroscopically as the largest-diameter ball probe as possible was inserted into its anterior third, middle, or posterior third portion with the ankle in natural plantarflexion or under external rotational stress. These measurements were performed for the uninjured ankle and then performed following Bassett's ligament sectioning, anterior inferior tibiofibular ligament sectioning, interosseous membrane distal 15 cm sectioning, or deltoid ligament, and posterior inferior tibiofibular ligament sectioning, with the sections added in this sequence and each followed by a similar assessment. The results of quantitative assessment of tibiofibular space widening with the ball-tipped probe in the syndesmosis injury model under arthroscopy were that the maximum possible diameter of ball probe that could be inserted was 1.5 to 2.0 mm in the uninjured state, 3.0 to 3.5 mm in the sectioned anterior inferior tibiofibular ligament model, and 5.0 mm in the severe-state model. The ball probe can serve as an effective tool for quantitative assessment of the intraoperative instability in cases of syndesmosis injury.
Identifiants
pubmed: 32893107
pii: S1067-2516(20)30254-4
doi: 10.1053/j.jfas.2020.03.024
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1215-1218Informations de copyright
Copyright © 2020 the American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.