Résumé

The effect of time on the validity of electromyography (EMG) signals from indwelling fine-wire electrodes has not been explored. This is important because experiments using intramuscular electrodes are often long and biochemical and mechanical factors, may impair measurement accuracy over time. Measures over extended periods might therefore be erroneous. Twelve healthy participants (age = 33 ± 8 years) walked for 50 min at a controlled speed. Fine-wire electrodes were inserted into tibialis anterior and a surface EMG sensor attached near the fine-wire insertion site. EMG signals progressively and significantly decreased with time with the fine-wire electrode, but not the surface electrode. For the fine-wire electrode, after 25 min mean amplitude had reduced by 11% (p < 0.001) and after 50 min by 16% (p < 0.001), and peak amplitude reduced 22% at 20 min (p = 0.006) and 37% at 50 min (p < 0.001). Reduced amplitude with indwelling EMG without concurrent changes in surface EMG signal suggests an important inconsistency in data from fine-wire EMG electrodes. Changes in EMG signal will occur over time independent of the experimental condition and this questions their use in experiments of more than 30 min. These results should impact on experimental study design. They also invite reinterpretation of prior literature and sensor innovation to improve measurement performance.

Identifiants

pubmed: 32905962
pii: S1050-6411(20)30103-6
doi: 10.1016/j.jelekin.2020.102461
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

102461

Informations de copyright

Copyright © 2020 Elsevier Ltd. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Joanna Reeves (J)

Centre for Health Sciences Research, University of Salford, Salford, United Kingdom; Faculty of Health Sciences, University of Ottawa, Ottawa, Canada. Electronic address: j.e.reeves@edu.salford.ac.uk.

Chelsea Starbuck (C)

Centre for Health Sciences Research, University of Salford, Salford, United Kingdom.

Christopher Nester (C)

Centre for Health Sciences Research, University of Salford, Salford, United Kingdom.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH