Does the Grip Width Affect the Bench Press Performance of Paralympic Powerlifters?
bar velocity
dynamic strength
electromyography
isometric strength
powerlifting
Journal
International journal of sports physiology and performance
ISSN: 1555-0273
Titre abrégé: Int J Sports Physiol Perform
Pays: United States
ID NLM: 101276430
Informations de publication
Date de publication:
01 Oct 2020
01 Oct 2020
Historique:
received:
06
10
2019
revised:
28
11
2019
accepted:
16
12
2019
medline:
12
9
2020
pubmed:
12
9
2020
entrez:
11
9
2020
Statut:
epublish
Résumé
To verify the effects of using different grip widths in bench press performance in Paralympic powerlifting athletes. Twelve experienced Paralympic powerlifting male athletes (25.40 [3.30] y, 70.30 [12.15] kg) participated in the study. Maximal dynamic strength and maximal isometric strength (MIS) were determined. Then, mean propulsive velocity (MPV) using 25%, 50%, and 100% of maximal dynamic strength load and time to achieve 30%, 50%, and 100% of MIS were assessed with 4 different grip widths, specifically the biacromial distance (BAD: 42.83 [12.84] cm), 1.3 BAD (55.68 [16.70] cm), 1.5 BAD (63.20 [18.96] cm), and 81 cm. Electromyographic analysis was performed during MIS assessment in the pectoralis major sternal portion, anterior deltoid, triceps brachii long head, and pectoralis major clavicular portion. Large differences were found between MPV performed with different grip widths using 25% of maximal dynamic strength load (P = .02, ηp2=.26). The 1.5 BAD grip tended to show greater force generation and MPV. Moreover, the time needed to achieve 30%, 50%, and 100% of MIS differed between grip widths (P = .03, ηp2=.24), with the lowest values obtained in the 1.5 BAD. Despite the nonstatistical differences that were found, grip widths caused moderate effects on muscle myoelectric activation, showing greater values for pectoralis major clavicular portion and pectoralis major sternal portion, for the 1.3 BAD and 1.5 BAD, respectively. The 1.5 BAD the grip width tended to show greater MPV values and faster contractile responses. These results highlighted the importance of choosing the specific grip width for improvement of performance in Paralympic powerlifting athletes, by increasing velocity of movement and force production in a shorter time, with greater activation of primary muscles.
Identifiants
pubmed: 32916657
doi: 10.1123/ijspp.2019-0784
pii: ijspp.2019-0784
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM