Radiation Exposure in Minimally Invasive Lumbar Fusion Surgery: A Randomized Controlled Trial Comparing Conventional Fluoroscopy and 3D Fluoroscopy-based Navigation.


Journal

Spine
ISSN: 1528-1159
Titre abrégé: Spine (Phila Pa 1976)
Pays: United States
ID NLM: 7610646

Informations de publication

Date de publication:
01 Jan 2021
Historique:
pubmed: 15 9 2020
medline: 9 3 2021
entrez: 14 9 2020
Statut: ppublish

Résumé

Randomized controlled trial. The aim of this study was to compare the dosemetrically determined radiation exposure of surgeon and patient during minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) using conventional 2D fluoroscopy (FLUORO) or 3D fluoroscopy-based navigation (NAV). MIS TLIF was shown to exhibit higher radiation exposures compared to open techniques. In particular, the routinely exposed surgeon encounters the risks of increased radiation doses. With the additional use of intraoperative 3D navigation, major steps of the operation can be performed without exposing the operating room staff to ionizing radiation. Forty-four patients undergoing monosegmental MIS TLIF were randomized into the two intraoperative imaging technique groups (FLUORO or NAV). The primary endpoint was the radiation exposure of the surgeon; the secondary endpoints were the radiation exposure of the patient and C-arm readings. After exclusion of three patients, 41 patients were analyzed. In general, the average radiation exposure of the surgeon was lower in the NAV group without being statistically significant. The radiation exposure of the patient was significantly higher in the NAV group at all dosemeter sites. The average fluoroscopy time was 63 ± 36 versus 109 ± 31 sec (FLUORO versus NAV group, P < 0.001). The additional use of intraoperative 3D fluoroscopy-based navigation compared to conventional 2D fluoroscopy alone showed a nonsignificant reduction of the radiation exposure of the surgeon in monosegmental MIS TLIF, while increasing the radiation exposure of the patient. 1.

Sections du résumé

STUDY DESIGN METHODS
Randomized controlled trial.
OBJECTIVE OBJECTIVE
The aim of this study was to compare the dosemetrically determined radiation exposure of surgeon and patient during minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) using conventional 2D fluoroscopy (FLUORO) or 3D fluoroscopy-based navigation (NAV).
SUMMARY OF BACKGROUND DATA BACKGROUND
MIS TLIF was shown to exhibit higher radiation exposures compared to open techniques. In particular, the routinely exposed surgeon encounters the risks of increased radiation doses. With the additional use of intraoperative 3D navigation, major steps of the operation can be performed without exposing the operating room staff to ionizing radiation.
METHODS METHODS
Forty-four patients undergoing monosegmental MIS TLIF were randomized into the two intraoperative imaging technique groups (FLUORO or NAV). The primary endpoint was the radiation exposure of the surgeon; the secondary endpoints were the radiation exposure of the patient and C-arm readings.
RESULTS RESULTS
After exclusion of three patients, 41 patients were analyzed. In general, the average radiation exposure of the surgeon was lower in the NAV group without being statistically significant. The radiation exposure of the patient was significantly higher in the NAV group at all dosemeter sites. The average fluoroscopy time was 63 ± 36 versus 109 ± 31 sec (FLUORO versus NAV group, P < 0.001).
CONCLUSION CONCLUSIONS
The additional use of intraoperative 3D fluoroscopy-based navigation compared to conventional 2D fluoroscopy alone showed a nonsignificant reduction of the radiation exposure of the surgeon in monosegmental MIS TLIF, while increasing the radiation exposure of the patient.
LEVEL OF EVIDENCE METHODS
1.

Identifiants

pubmed: 32925679
doi: 10.1097/BRS.0000000000003685
pii: 00007632-202101010-00002
doi:

Types de publication

Clinical Trial Journal Article Randomized Controlled Trial

Langues

eng

Sous-ensembles de citation

IM

Pagination

1-8

Références

Lee KH, Yue WM, Yeo W, et al. Clinical and radiological outcomes of open versus minimally invasive transforaminal lumbar interbody fusion. Eur Spine J 2012; 21:2265–2270.
Foley KT, Holly LT, Schwender JD. Minimally invasive lumbar fusion. Spine (Phila Pa 1976) 2003; 28: (15 suppl): S26–S35.
Tian N-F, Wu Y-S, Zhang X-L, et al. Minimally invasive versus open transforaminal lumbar interbody fusion: a meta-analysis based on the current evidence. Eur Spine J 2013; 22:1741–1749.
Vazan M, Gempt J, Meyer B, et al. Minimally invasive transforaminal lumbar interbody fusion versus open transforaminal lumbar interbody fusion: a technical description and review of the literature. Acta Neurochir (Wien) 2017; 159:1137–1146.
Klingler JH, Sircar R, Scheiwe C, et al. Comparative study of C-arms for intraoperative 3-dimensional imaging and navigation in minimally invasive spine surgery part I—applicability and image quality. Clin Spine Surg 2016; 1doi:10.1097/BSD.0000000000000186.
doi: 10.1097/BSD.0000000000000186
Stubig T, Kendoff D, Citak M, et al. Comparative study of different intraoperative 3-D image intensifiers in orthopedic trauma care. J Trauma 2009; 66:821–830.
Hubbe U, Sircar R, Scheiwe C, et al. Surgeon, staff, and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion: impact of 3D fluoroscopy-based navigation partially replacing conventional fluoroscopy: study protocol for a randomized controlled trial. Trials 2015; 16:142doi:10.1186/s13063-015-0690-5.
doi: 10.1186/s13063-015-0690-5
Berjano P, Lamartina C. Classification of degenerative segment disease in adults with deformity of the lumbar or thoracolumbar spine. Eur Spine J 2014; 23:1815–1824.
Joint Committee for Guides in Metrology, 2008. Evaluation of measurement data - guide to the expression of uncertainty in measurement. GUM 1995 with minor corrections, JCGM 2008; 100.
Bindal RK, Glaze S, Ognoskie M, et al. Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion. J Neurosurg Spine 2008; 9:570–573.
Rampersaud YR, Foley KT, Shen AC, et al. Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 2000; 25:2637–2645.
Klingler JH, Sircar R, Scheiwe C, et al. Comparative study of C-arms for intraoperative 3-dimensional imaging and navigation in minimally invasive spine surgery part II: radiation exposure. Clin Spine Surg 2017; 30:E669–E676.
Mroz TE, Abdullah KG, Steinmetz MP, et al. Radiation exposure to the surgeon during percutaneous pedicle screw placement. J Spinal Disord Tech 2011; 24:264–267.
Theocharopoulos N, Perisinakis K, Damilakis J, et al. Occupational exposure from common fluoroscopic projections used in orthopaedic surgery. J Bone Joint Surg Am 2003; 85-A:1698–1703.
Jones DP, Robertson PA, Lunt B, et al. Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine. Spine (Phila Pa 1976) 2000; 25:1538–1541.
Kim CW, Lee Y-P, Taylor W, et al. Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery. Spine J 2008; 8:584–590.
Slomczykowski M, Roberto M, Schneeberger P, et al. Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery. Spine (Phila Pa 1976) 1999; 24:975–982. –discussion983.
Funao H, Ishii K, Momoshima S, et al. Surgeons’ exposure to radiation in single- and multi-level minimally invasive transforaminal lumbar interbody fusion; a prospective study. PLoS One 2014; 9:e95233doi:10.1371/journal.pone.0095233.
doi: 10.1371/journal.pone.0095233
Villard J, Ryang Y-M, Demetriades AK, et al. Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques. Spine (Phila Pa 1976) 2014; 39:1004–1009.
Stewart FA, Akleyev AV, Hauer-Jensen M, et al. ICRP, 2012. ICRP statement on tissue reactions /early and late effects of radiation in normal tissues and organs—threshold doses for tissue reactions in a radiation protection context. ICRP Publication 118. Ann ICRP 2012; 41:1–322.
Schauer DA, Linton OW. NCRP Report No. 160, ionizing radiation exposure of the population of the United States, medical exposure—are we doing less with more, and is there a role for health physicists? Health Phys 2009; 97:1–5.
Perisinakis K, Theocharopoulos N, Damilakis J, et al. Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion. Spine (Phila Pa 1976) 2004; 29:1555–1560.
Giordano BD, Baumhauer JF, Morgan TL, et al. Cervical spine imaging using standard C-arm fluoroscopy: patient and surgeon exposure to ionizing radiation. Spine (Phila Pa 1976) 2008; 33:1970–1976.

Auteurs

Jan-Helge Klingler (JH)

Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.

Christoph Scholz (C)

Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.

Marie T Krüger (MT)

Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.
Department of Neurosurgery, Cantonal Hospital St. Gallen, St. Gallen, Switzerland.

Yashar Naseri (Y)

Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.
Department of Neurosurgery, Cantonal Hospital St. Gallen, St. Gallen, Switzerland.

Florian Volz (F)

Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.

Marc Hohenhaus (M)

Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.

Johannes Brönner (J)

Helmholtz Zentrum München, German Research Center for Environmental Health, Individual Monitoring Service, Munich, Germany.

Herbert Hoedlmoser (H)

Helmholtz Zentrum München, German Research Center for Environmental Health, Individual Monitoring Service, Munich, Germany.

Ronen Sircar (R)

Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.

Ulrich Hubbe (U)

Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH