[Keratoconus detection and classification from parameters of the Corvis®ST : A study based on algorithms of machine learning].

Keratokonusdetektion und Ableitung des Ausprägungsgrades aus den Parametern des Corvis®ST : Eine Studie, basierend auf Algorithmen des Maschinenlernens.
Artificial intelligence Corvis Keratoconus Scheimpflug corneal tomography Supervised machine learning

Journal

Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft
ISSN: 1433-0423
Titre abrégé: Ophthalmologe
Pays: Germany
ID NLM: 9206148

Informations de publication

Date de publication:
Jul 2021
Historique:
received: 20 04 2020
accepted: 24 08 2020
revised: 23 08 2020
pubmed: 25 9 2020
medline: 9 7 2021
entrez: 24 9 2020
Statut: ppublish

Résumé

In the last decades increasingly more systems of artificial intelligence have been established in medicine, which identify diseases or pathologies or discriminate them from complimentary diseases. Up to now the Corvis®ST (Corneal Visualization Scheimpflug Technology, Corvis®ST, Oculus, Wetzlar, Germany) yielded a binary index for classifying keratoconus but did not enable staging. The purpose of this study was to develop a prediction model, which mimics the topographic keratoconus classification index (TKC) of the Pentacam high resolution (HR, Oculus) with measurement parameters extracted from the Corvis®ST. In this study 60 measurements from normal subjects (TKC 0) and 379 eyes with keratoconus (TKC 1-4) were recruited. After measurement with the Pentacam HR (target parameter TKC) a measurement with the Corvis®ST device was performed. From this device 6 dynamic response parameters were extracted, which were included in the Corvis biomechanical index (CBI) provided by the Corvis®ST (ARTh, SP-A1, DA ratio 1 mm, DA ratio 2 mm, A1 velocity, max. deformation amplitude). In addition to the TKC as the target, the binarized TKC (1: TKC 1-4, 0: TKC 0) was modelled. The performance of the model was validated with accuracy as an indicator for correct classification made by the algorithm. Misclassifications in the modelling were penalized by the number of stages of deviation between the modelled and measured TKC values. A total of 24 different models of supervised machine learning from 6 different families were tested. For modelling of the TKC stages 0-4, the algorithm based on a support vector machine (SVM) with linear kernel showed the best performance with an accuracy of 65.1% correct classifications. For modelling of binarized TKC, a decision tree with a coarse resolution showed a superior performance with an accuracy of 95.2% correct classifications followed by the SVM with linear or quadratic kernel and a nearest neighborhood classifier with cubic kernel (94.5% each). This study aimed to show the principle of supervised machine learning applied to a set-up for the modelled classification of keratoconus staging. Preprocessed measurement data extracted from the Corvis®ST device were used to mimic the TKC provided by the Pentacam device with a series of different algorithms of machine learning. HINTERGRUND UND ZIELSETZUNG: In den vergangenen Jahren wurden zunehmend Systeme der künstlichen Intelligenz in der Medizin etabliert, die Pathologien oder Erkrankungen erkennen oder von komplementären Erkrankungen abgrenzen. Bisher liefert das Corvis®ST (Corneal Visualization Scheimpflug Technology, Oculus, Wetzlar, Deutschland) einen Index-CBI, der quasi binär Keratokonus klassifiziert, aber kein Staging zulässt. Ziel der Studie ist es, anhand von Messgrößen des Corvis®ST ein Vorhersagemodell zu entwerfen, das den Topographic Keratoconus Classification Index (TKC) der Pentacam high resolution (HR, Oculus) nachbildet. Es wurden 60 Messungen an Normalprobanden (TKC 0) und 379 Augen mit Keratokonus (TKC 1 bis 4) in die Studie mit einbezogen. Nach der Messung mit der Pentacam HR (Zielgröße TKC) wurde eine Untersuchung mit dem Corvis®ST durchgeführt, aus der 6 Messparameter extrahiert wurden, die in den Corvis Biomechanical Index CBI eingehen (ARTh, SP-A1, DA-Ratio 1 mm, DA-Ratio 2 mm, A1 velocity, max. Deformation Amplitude). Neben dem TKC als Zielgröße wurde der binarisierte TKC (1: TKC 1 bis 4, 0: TKC 0) modelliert. Als Gütemaß wurde die Genauigkeit des Modells als Anteil der korrekten Klassifizierungen herangezogen. Fehlklassifizierungen wurden in der Modellierung so bestraft, dass die Abweichung des modellierten TKC-Wertes vom gemessenen Wert bewertet wurde. Es wurden 24 verschiedene Modelle des überwachten maschinellen Lernens aus 6 Familien getestet. Für die Modellierung des TKC in Stufen von 0–4 zeigte das Modell, basierend auf einer Support Vector Machine (SVM) mit linearem Kernel, die beste Performance mit einem Anteil an richtigen Klassifizierungen von 65,1 %. Für den binarisierten Wert des TKC zeigte ein Decision Tree mit grober Auflösung die beste Performance mit einem Anteil an richtigen Klassifizierungen von 95,2 %, direkt gefolgt von der SVM mit linearem oder quadratischem Kernel und dem Nearest Neighborhood Classifier mit kubischem Kernel (jeweils 94,5 %). In der Arbeit soll das Prinzip des überwachten Maschinenlernens in der Anwendung auf die modellierte Klassifizierung von Messbefunden gezeigt werden. So wurden Messdaten des Corvis®ST dazu verwendet, die Einteilung in den Schweregrad eines Keratokonus mittels Pentacam (TKC) mit einer ganzen Reihe von Algorithmen des maschinellen Lernens nachzubilden.

Sections du résumé

BACKGROUND AND OBJECTIVE OBJECTIVE
In the last decades increasingly more systems of artificial intelligence have been established in medicine, which identify diseases or pathologies or discriminate them from complimentary diseases. Up to now the Corvis®ST (Corneal Visualization Scheimpflug Technology, Corvis®ST, Oculus, Wetzlar, Germany) yielded a binary index for classifying keratoconus but did not enable staging. The purpose of this study was to develop a prediction model, which mimics the topographic keratoconus classification index (TKC) of the Pentacam high resolution (HR, Oculus) with measurement parameters extracted from the Corvis®ST.
PATIENTS AND METHODS METHODS
In this study 60 measurements from normal subjects (TKC 0) and 379 eyes with keratoconus (TKC 1-4) were recruited. After measurement with the Pentacam HR (target parameter TKC) a measurement with the Corvis®ST device was performed. From this device 6 dynamic response parameters were extracted, which were included in the Corvis biomechanical index (CBI) provided by the Corvis®ST (ARTh, SP-A1, DA ratio 1 mm, DA ratio 2 mm, A1 velocity, max. deformation amplitude). In addition to the TKC as the target, the binarized TKC (1: TKC 1-4, 0: TKC 0) was modelled. The performance of the model was validated with accuracy as an indicator for correct classification made by the algorithm. Misclassifications in the modelling were penalized by the number of stages of deviation between the modelled and measured TKC values.
RESULTS RESULTS
A total of 24 different models of supervised machine learning from 6 different families were tested. For modelling of the TKC stages 0-4, the algorithm based on a support vector machine (SVM) with linear kernel showed the best performance with an accuracy of 65.1% correct classifications. For modelling of binarized TKC, a decision tree with a coarse resolution showed a superior performance with an accuracy of 95.2% correct classifications followed by the SVM with linear or quadratic kernel and a nearest neighborhood classifier with cubic kernel (94.5% each).
CONCLUSION CONCLUSIONS
This study aimed to show the principle of supervised machine learning applied to a set-up for the modelled classification of keratoconus staging. Preprocessed measurement data extracted from the Corvis®ST device were used to mimic the TKC provided by the Pentacam device with a series of different algorithms of machine learning.
ZUSAMMENFASSUNG UNASSIGNED
HINTERGRUND UND ZIELSETZUNG: In den vergangenen Jahren wurden zunehmend Systeme der künstlichen Intelligenz in der Medizin etabliert, die Pathologien oder Erkrankungen erkennen oder von komplementären Erkrankungen abgrenzen. Bisher liefert das Corvis®ST (Corneal Visualization Scheimpflug Technology, Oculus, Wetzlar, Deutschland) einen Index-CBI, der quasi binär Keratokonus klassifiziert, aber kein Staging zulässt. Ziel der Studie ist es, anhand von Messgrößen des Corvis®ST ein Vorhersagemodell zu entwerfen, das den Topographic Keratoconus Classification Index (TKC) der Pentacam high resolution (HR, Oculus) nachbildet.
PATIENTEN UND METHODEN UNASSIGNED
Es wurden 60 Messungen an Normalprobanden (TKC 0) und 379 Augen mit Keratokonus (TKC 1 bis 4) in die Studie mit einbezogen. Nach der Messung mit der Pentacam HR (Zielgröße TKC) wurde eine Untersuchung mit dem Corvis®ST durchgeführt, aus der 6 Messparameter extrahiert wurden, die in den Corvis Biomechanical Index CBI eingehen (ARTh, SP-A1, DA-Ratio 1 mm, DA-Ratio 2 mm, A1 velocity, max. Deformation Amplitude). Neben dem TKC als Zielgröße wurde der binarisierte TKC (1: TKC 1 bis 4, 0: TKC 0) modelliert. Als Gütemaß wurde die Genauigkeit des Modells als Anteil der korrekten Klassifizierungen herangezogen. Fehlklassifizierungen wurden in der Modellierung so bestraft, dass die Abweichung des modellierten TKC-Wertes vom gemessenen Wert bewertet wurde.
ERGEBNISSE UNASSIGNED
Es wurden 24 verschiedene Modelle des überwachten maschinellen Lernens aus 6 Familien getestet. Für die Modellierung des TKC in Stufen von 0–4 zeigte das Modell, basierend auf einer Support Vector Machine (SVM) mit linearem Kernel, die beste Performance mit einem Anteil an richtigen Klassifizierungen von 65,1 %. Für den binarisierten Wert des TKC zeigte ein Decision Tree mit grober Auflösung die beste Performance mit einem Anteil an richtigen Klassifizierungen von 95,2 %, direkt gefolgt von der SVM mit linearem oder quadratischem Kernel und dem Nearest Neighborhood Classifier mit kubischem Kernel (jeweils 94,5 %).
SCHLUSSFOLGERUNGEN UNASSIGNED
In der Arbeit soll das Prinzip des überwachten Maschinenlernens in der Anwendung auf die modellierte Klassifizierung von Messbefunden gezeigt werden. So wurden Messdaten des Corvis®ST dazu verwendet, die Einteilung in den Schweregrad eines Keratokonus mittels Pentacam (TKC) mit einer ganzen Reihe von Algorithmen des maschinellen Lernens nachzubilden.

Autres résumés

Type: Publisher (ger)
HINTERGRUND UND ZIELSETZUNG: In den vergangenen Jahren wurden zunehmend Systeme der künstlichen Intelligenz in der Medizin etabliert, die Pathologien oder Erkrankungen erkennen oder von komplementären Erkrankungen abgrenzen. Bisher liefert das Corvis®ST (Corneal Visualization Scheimpflug Technology, Oculus, Wetzlar, Deutschland) einen Index-CBI, der quasi binär Keratokonus klassifiziert, aber kein Staging zulässt. Ziel der Studie ist es, anhand von Messgrößen des Corvis®ST ein Vorhersagemodell zu entwerfen, das den Topographic Keratoconus Classification Index (TKC) der Pentacam high resolution (HR, Oculus) nachbildet.

Identifiants

pubmed: 32970190
doi: 10.1007/s00347-020-01231-1
pii: 10.1007/s00347-020-01231-1
pmc: PMC8260544
doi:

Types de publication

Journal Article

Langues

ger

Sous-ensembles de citation

IM

Pagination

697-706

Références

Cornea. 2020 Feb;39(2):215-221
pubmed: 31478950
Zhonghua Yan Ke Za Zhi. 2019 Dec 11;55(12):911-915
pubmed: 31874504
Zhongguo Yi Liao Qi Xie Za Zhi. 2019 Mar 30;43(2):83-85
pubmed: 30977600
JAMA Ophthalmol. 2020 May 1;138(5):519-526
pubmed: 32215587
Curr Pharm Des. 2018;24(37):4474-4483
pubmed: 30582471
Am J Ophthalmol. 2015 Apr;159(4):733-8
pubmed: 25634534
Am J Ophthalmol. 2018 Nov;195:223-232
pubmed: 30098348
J Cataract Refract Surg. 2019 Jun;45(6):778-788
pubmed: 30902432
Klin Monbl Augenheilkd. 2013 Oct;230(10):998-1004
pubmed: 23842872
Invest Ophthalmol Vis Sci. 1997 Oct;38(11):2290-9
pubmed: 9344352
Int J Environ Res Public Health. 2020 Mar 23;17(6):
pubmed: 32209975
Klin Monbl Augenheilkd. 1999 Apr;214(4):217-23
pubmed: 10407803
Invest Ophthalmol Vis Sci. 1995 Jun;36(7):1327-35
pubmed: 7775110
Big Data. 2019 Dec;7(4):221-248
pubmed: 31411491
Comput Math Methods Med. 2017;2017:5293573
pubmed: 28270858
Ophthalmology. 2018 Dec;125(12):1872-1873
pubmed: 30454713
Cornea. 2018 Aug;37(8):1025-1034
pubmed: 29847493
Arch Ophthalmol. 1995 Jul;113(7):870-4
pubmed: 7605277
Cornea. 2016 Jun;35(6):827-32
pubmed: 27055215
J Refract Surg. 2017 Jul 1;33(7):434-443
pubmed: 28681902
J Cataract Refract Surg. 2016 Feb;42(2):275-83
pubmed: 27026453
J Refract Surg. 2016 Dec 1;32(12):803-810
pubmed: 27930790
PLoS One. 2018 Nov 6;13(11):e0205998
pubmed: 30399144
Pathologe. 2020 Nov;41(6):649-658
pubmed: 33052431
Semin Ophthalmol. 2019;34(4):317-326
pubmed: 31304857
Ophthalmologe. 2001 Jan;98(1):54-9
pubmed: 11220272
Klin Monbl Augenheilkd. 2019 Dec;236(12):1423-1427
pubmed: 31805593
J Cataract Refract Surg. 2000 Apr;26(4):472-4
pubmed: 10819626
Invest Ophthalmol Vis Sci. 1994 May;35(6):2749-57
pubmed: 8188468
Ophthalmologe. 2013 Sep;110(9):808-9
pubmed: 23990150
Comput Intell Neurosci. 2019 Jan 23;2019:8162567
pubmed: 30809255
Br J Ophthalmol. 2009 Jul;93(7):845-7
pubmed: 19553507
Cornea. 2015 Aug;34(8):e20-2
pubmed: 26075463

Auteurs

Achim Langenbucher (A)

Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Kirrberger Str., Gebäude 22, 66421, Homburg, Deutschland. achim.langenbucher@uks.eu.

Larissa Häfner (L)

Klinik für Augenheilkunde, Universitätsklinikum des Saarlandes, Kirrberger Str., Gebäude 22, 66421, Homburg, Deutschland.

Timo Eppig (T)

Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Kirrberger Str., Gebäude 22, 66421, Homburg, Deutschland.

Berthold Seitz (B)

Klinik für Augenheilkunde, Universitätsklinikum des Saarlandes, Kirrberger Str., Gebäude 22, 66421, Homburg, Deutschland.

Nóra Szentmáry (N)

Dr. Rolf M. Schwiete Zentrum für Limbusstammzellforschung und kongenitale Aniridie, Universität des Saarlandes, Kirrberger Str., Gebäude 22, 66421, Homburg, Deutschland.

Elias Flockerzi (E)

Klinik für Augenheilkunde, Universitätsklinikum des Saarlandes, Kirrberger Str., Gebäude 22, 66421, Homburg, Deutschland.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH