[Combination of lens decentration and tilt in phakic and pseudophakic eyes-Optical simulation of defocus, astigmatism and coma].
Kombination aus Dezentrierung und Verkippung der Linse im phaken und pseudophaken Auge – optische Simulation von Defokus, Astigmatismus und Coma.
Image performance
Intraocular lens
Lens alignment
Modelling
Raytracing
Journal
Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft
ISSN: 1433-0423
Titre abrégé: Ophthalmologe
Pays: Germany
ID NLM: 9206148
Informations de publication
Date de publication:
Aug 2021
Aug 2021
Historique:
received:
31
07
2020
accepted:
02
09
2020
pubmed:
1
10
2020
medline:
10
8
2021
entrez:
30
9
2020
Statut:
ppublish
Résumé
The effect of lens decentration and tilt on retinal image quality has been extensively studied in the past in simulations and clinical studies. The purpose of this study was to analyze the effect of combined lens decentration and tilt on the induction of defocus, astigmatism and coma in phakic and pseudophakic eyes. Simulations were performed with Zemax on the Liou-Brennan schematic model eye. Based on the position of the gradient lens the image plane was determined (best focus). The lens was decentered horizontally from -1.0 mm to 1.0 mm in steps of 0.2 mm and tilted with respect to the vertical axis from -10° to 10° in steps of 2° (in total 121 combinations of decentration and tilt). For each combination of decentration and tilt defocus, astigmatism (in 0/180°) and horizontal coma was extracted from wave front error and recorded for a pupil size of 4 mm. After replacement of the gradient lens with an aberration correcting artificial lens implant model with the equatorial plane of the artificial lens aligned to the equatorial plane of the gradient lens, the simulations were repeated for the pseudophakic eye model. For the lens positioned according to the Liou-Brennan schematic model eye the simulation yielded a defocus of 0.026 dpt/-0.001 dpt, astigmatism of -0.045 dpt/-0.018 dpt, and a coma of -0.015 µm/0.047 µm for phakic/pseudophakic eyes. Maximum values were observed for a horizontal decentration of 1.0 mm and a tilt with respect to the vertical axis of 10° with 1.547 dpt/2.982 dpt for defocus, 0.971 dpt/1.871 dpt for astigmatism, and 0.441 µm/1.209 µm for coma. Maximum negative values occurred in phakic/pseudophakic eyes with -0.293 dpt/-1.224 dpt for defocus, for astigmatism -0.625 dpt/-0.663 dpt and for coma -0.491 µm /-0.559 µm, respectively. In this simulation study the effect of a combination of lens decentration in horizontal direction and tilt with respect to the vertical axis on defocus, astigmatism and horizontal coma was analyzed. The results may help to describe in clinical routine if with a decentered or tilted artificial lens implant the postoperative refraction does not match the target refraction or the resulting astigmatism after cataract surgery is not fully explained by measurement of corneal astigmatism. HINTERGRUND UND ZIELSETZUNG: Der Einfluss von Dezentrierung und Verkippung von Kunstlinsen auf die Abbildungsqualität ist in den vergangenen Jahren ausgiebig in Simulationen wie auch klinischen Studien untersucht worden. Ziel dieser Arbeit ist es, den Einfluss der Dezentrierung und Verkippung auf die Induktion von Defokus, Astigmatismus und Coma im phaken und pseudophaken Auge zu untersuchen. Auf der Basis des Liou-Brennan-Modellauges wurde eine Simulation mit Zemax durchgeführt. Ausgehend von der im Augenmodell beschriebenen Position der Gradientenlinse, wurde nach der Bestimmung der Fokusebene die Linse von −1,0 bis 1,0 mm in Schritten von 0,2 mm horizontal dezentriert und von −10° bis 10° in Schritten von 2° um die vertikale Achse verkippt. Zu jeder der 121 Kombinationen wurde bei einer Pupille von 4 mm der Defokus, der reguläre Astigmatismus in 0/180° sowie die horizontale Coma aus der Wellenfront extrahiert. Analog zum phaken Auge wurde die Gradientenlinse durch ein aberrationskorrigierendes Kunstlinsenmodell ersetzt und die Simulation für das pseudophake Auge wiederholt. Ist die Linse im phaken/pseudophaken Auge entsprechend den Vorgaben des Liou-Brennan-Modellauges positioniert, ergibt die Simulation einen Defokus von 0,026/−0,001 dpt, einen Astigmatismus von −0,045/−0,018 dpt sowie eine Coma von −0,015/0,047 µm. Maximale Werte treten bei einer Dezentrierung von 1,0 mm und einer Verkippung von 10° auf: 1,547/2,982 dpt für den Defokus, 0,971/1,871 dpt für den Astigmatismus sowie 0,441/1,209 µm für die Coma. Maximal negative Werte treten im phaken/pseudophaken Auge auf bei: −0,293/−1,224 dpt für den Defokus, −0,625/−0,663 dpt für den Astigmatismus sowie −0,491/−0,559 µm für die Coma. In dieser Studie wurde erstmals der Effekt einer Kombination aus horizontaler Dezentrierung der Linse und Verkippung um die Vertikale auf den induzierten Defokus, Astigmatismus sowie die horizontale Coma in einem Simulationsmodell untersucht. Die Ergebnisse können bei der Ursachenforschung helfen, wenn bei dezentrierter oder verkippter Kunstlinse die Zielrefraktion nicht mit der erreichten Refraktion übereinstimmt oder der resultierende Astigmatismus durch den Hornhautastigmatismus alleine nicht erklärbar ist.
Sections du résumé
BACKGROUND AND PURPOSE
OBJECTIVE
The effect of lens decentration and tilt on retinal image quality has been extensively studied in the past in simulations and clinical studies. The purpose of this study was to analyze the effect of combined lens decentration and tilt on the induction of defocus, astigmatism and coma in phakic and pseudophakic eyes.
METHODS
METHODS
Simulations were performed with Zemax on the Liou-Brennan schematic model eye. Based on the position of the gradient lens the image plane was determined (best focus). The lens was decentered horizontally from -1.0 mm to 1.0 mm in steps of 0.2 mm and tilted with respect to the vertical axis from -10° to 10° in steps of 2° (in total 121 combinations of decentration and tilt). For each combination of decentration and tilt defocus, astigmatism (in 0/180°) and horizontal coma was extracted from wave front error and recorded for a pupil size of 4 mm. After replacement of the gradient lens with an aberration correcting artificial lens implant model with the equatorial plane of the artificial lens aligned to the equatorial plane of the gradient lens, the simulations were repeated for the pseudophakic eye model.
RESULTS
RESULTS
For the lens positioned according to the Liou-Brennan schematic model eye the simulation yielded a defocus of 0.026 dpt/-0.001 dpt, astigmatism of -0.045 dpt/-0.018 dpt, and a coma of -0.015 µm/0.047 µm for phakic/pseudophakic eyes. Maximum values were observed for a horizontal decentration of 1.0 mm and a tilt with respect to the vertical axis of 10° with 1.547 dpt/2.982 dpt for defocus, 0.971 dpt/1.871 dpt for astigmatism, and 0.441 µm/1.209 µm for coma. Maximum negative values occurred in phakic/pseudophakic eyes with -0.293 dpt/-1.224 dpt for defocus, for astigmatism -0.625 dpt/-0.663 dpt and for coma -0.491 µm /-0.559 µm, respectively.
CONCLUSION
CONCLUSIONS
In this simulation study the effect of a combination of lens decentration in horizontal direction and tilt with respect to the vertical axis on defocus, astigmatism and horizontal coma was analyzed. The results may help to describe in clinical routine if with a decentered or tilted artificial lens implant the postoperative refraction does not match the target refraction or the resulting astigmatism after cataract surgery is not fully explained by measurement of corneal astigmatism.
ZUSAMMENFASSUNG
UNASSIGNED
HINTERGRUND UND ZIELSETZUNG: Der Einfluss von Dezentrierung und Verkippung von Kunstlinsen auf die Abbildungsqualität ist in den vergangenen Jahren ausgiebig in Simulationen wie auch klinischen Studien untersucht worden. Ziel dieser Arbeit ist es, den Einfluss der Dezentrierung und Verkippung auf die Induktion von Defokus, Astigmatismus und Coma im phaken und pseudophaken Auge zu untersuchen.
METHODEN
METHODS
Auf der Basis des Liou-Brennan-Modellauges wurde eine Simulation mit Zemax durchgeführt. Ausgehend von der im Augenmodell beschriebenen Position der Gradientenlinse, wurde nach der Bestimmung der Fokusebene die Linse von −1,0 bis 1,0 mm in Schritten von 0,2 mm horizontal dezentriert und von −10° bis 10° in Schritten von 2° um die vertikale Achse verkippt. Zu jeder der 121 Kombinationen wurde bei einer Pupille von 4 mm der Defokus, der reguläre Astigmatismus in 0/180° sowie die horizontale Coma aus der Wellenfront extrahiert. Analog zum phaken Auge wurde die Gradientenlinse durch ein aberrationskorrigierendes Kunstlinsenmodell ersetzt und die Simulation für das pseudophake Auge wiederholt.
ERGEBNISSE
UNASSIGNED
Ist die Linse im phaken/pseudophaken Auge entsprechend den Vorgaben des Liou-Brennan-Modellauges positioniert, ergibt die Simulation einen Defokus von 0,026/−0,001 dpt, einen Astigmatismus von −0,045/−0,018 dpt sowie eine Coma von −0,015/0,047 µm. Maximale Werte treten bei einer Dezentrierung von 1,0 mm und einer Verkippung von 10° auf: 1,547/2,982 dpt für den Defokus, 0,971/1,871 dpt für den Astigmatismus sowie 0,441/1,209 µm für die Coma. Maximal negative Werte treten im phaken/pseudophaken Auge auf bei: −0,293/−1,224 dpt für den Defokus, −0,625/−0,663 dpt für den Astigmatismus sowie −0,491/−0,559 µm für die Coma.
DISKUSSION
CONCLUSIONS
In dieser Studie wurde erstmals der Effekt einer Kombination aus horizontaler Dezentrierung der Linse und Verkippung um die Vertikale auf den induzierten Defokus, Astigmatismus sowie die horizontale Coma in einem Simulationsmodell untersucht. Die Ergebnisse können bei der Ursachenforschung helfen, wenn bei dezentrierter oder verkippter Kunstlinse die Zielrefraktion nicht mit der erreichten Refraktion übereinstimmt oder der resultierende Astigmatismus durch den Hornhautastigmatismus alleine nicht erklärbar ist.
Autres résumés
Type: Publisher
(ger)
HINTERGRUND UND ZIELSETZUNG: Der Einfluss von Dezentrierung und Verkippung von Kunstlinsen auf die Abbildungsqualität ist in den vergangenen Jahren ausgiebig in Simulationen wie auch klinischen Studien untersucht worden. Ziel dieser Arbeit ist es, den Einfluss der Dezentrierung und Verkippung auf die Induktion von Defokus, Astigmatismus und Coma im phaken und pseudophaken Auge zu untersuchen.
Identifiants
pubmed: 32997197
doi: 10.1007/s00347-020-01235-x
pii: 10.1007/s00347-020-01235-x
pmc: PMC8342384
doi:
Types de publication
Journal Article
Langues
ger
Sous-ensembles de citation
IM
Pagination
828-837Informations de copyright
© 2020. The Author(s).
Références
J Refract Corneal Surg. 1994 Sep-Oct;10(5):556-64
pubmed: 7530106
Ophthalmologe. 2012 Mar;109(3):263-70
pubmed: 22447423
J Cataract Refract Surg. 2019 May;45(5):662-668
pubmed: 30876781
J Opt Soc Am A Opt Image Sci Vis. 1997 Aug;14(8):1684-95
pubmed: 9248060
J Cataract Refract Surg. 2006 Apr;32(4):599-603
pubmed: 16698479
J Cataract Refract Surg. 2010 Sep;36(9):1529-35
pubmed: 20692566
J Cataract Refract Surg. 1995 Sep;21(5):552-5
pubmed: 7473119
Zhonghua Yan Ke Za Zhi. 2015 Apr;51(4):270-5
pubmed: 26081230
Optom Vis Sci. 2019 Oct;96(10):802-807
pubmed: 31592963
Ophthalmic Physiol Opt. 2006 Mar;26(2):180-8
pubmed: 16460318
J Cataract Refract Surg. 2018 Jul;44(7):889-896
pubmed: 30055694
Invest Ophthalmol Vis Sci. 2016 Oct 1;57(13):5263-5270
pubmed: 27701637
J Refract Surg. 2010 Jan;26(1):71-6
pubmed: 20199017
Ophthalmic Physiol Opt. 2005 Nov;25(6):568-75
pubmed: 16343132
J Opt Soc Am A Opt Image Sci Vis. 2018 Apr 1;35(4):561-566
pubmed: 29603938
J Cataract Refract Surg. 2009 Jun;35(6):1091-100
pubmed: 19465297
J Biomed Opt. 2006 Sep-Oct;11(5):054012
pubmed: 17092161
PLoS One. 2013;8(3):e59109
pubmed: 23554982
J Cataract Refract Surg. 1999 Jan;25(1):100-5
pubmed: 9888085
J Cataract Refract Surg. 1991 Sep;17(5):592-5
pubmed: 1941592
Yan Ke Xue Bao. 1998 Mar;14(1):13-6, 26
pubmed: 12580069
Vision Res. 2008 Jan;48(1):70-9
pubmed: 18054373
Clin Exp Optom. 2016 Mar;99(2):99-106
pubmed: 26969304