An experience of subglottic airway foreign body removal in a patient under tracheal intubation: a case report.

Airway foreign body Subglottic airway foreign body Under intubation

Journal

JA clinical reports
ISSN: 2363-9024
Titre abrégé: JA Clin Rep
Pays: Germany
ID NLM: 101682121

Informations de publication

Date de publication:
04 Oct 2020
Historique:
received: 11 08 2020
accepted: 25 09 2020
revised: 23 09 2020
entrez: 4 10 2020
pubmed: 5 10 2020
medline: 5 10 2020
Statut: epublish

Résumé

Removal of an airway foreign body is challenging to anesthesiologists. We report successful removal of an extremely rare foreign body between a tracheal tube and the trachea in patients under tracheal intubation. A 57-year-old male received total aortic arch replacement and postoperative mechanical ventilation. An airway foreign body was detected just below the glottis, outside the tracheal tube during mechanical ventilation after surgery in the intensive care unit. Before the removal procedure, we planned multiple strategies to cope with unexpected airway and breathing troubles. As a result, the foreign body was successfully removed orally by using a bronchial fiber, without extubation of the tracheal tube, under general anesthesia with dexmedetomidine and ketamine. We reported the successful removal of a foreign body in the subglottic airway of a patient under tracheal intubation.

Sections du résumé

BACKGROUND BACKGROUND
Removal of an airway foreign body is challenging to anesthesiologists. We report successful removal of an extremely rare foreign body between a tracheal tube and the trachea in patients under tracheal intubation.
CASE PRESENTATION METHODS
A 57-year-old male received total aortic arch replacement and postoperative mechanical ventilation. An airway foreign body was detected just below the glottis, outside the tracheal tube during mechanical ventilation after surgery in the intensive care unit. Before the removal procedure, we planned multiple strategies to cope with unexpected airway and breathing troubles. As a result, the foreign body was successfully removed orally by using a bronchial fiber, without extubation of the tracheal tube, under general anesthesia with dexmedetomidine and ketamine.
CONCLUSIONS CONCLUSIONS
We reported the successful removal of a foreign body in the subglottic airway of a patient under tracheal intubation.

Identifiants

pubmed: 33011931
doi: 10.1186/s40981-020-00382-z
pii: 10.1186/s40981-020-00382-z
pmc: PMC7533046
doi:

Types de publication

Journal Article

Langues

eng

Pagination

76

Références

Singapore Med J. 2009 Sep;50(9):871-4
pubmed: 19787173
JA Clin Rep. 2019 Jul 17;5(1):46
pubmed: 32026088
J Emerg Med. 2019 May;56(5):523-529
pubmed: 30879854
Case Rep Surg. 2019 Jan 23;2019:1296061
pubmed: 30809413
J Thorac Dis. 2017 Sep;9(9):3398-3409
pubmed: 29221325
Orphanet J Rare Dis. 2015 Aug 04;10:93
pubmed: 26238698
J Anesth. 2014 Aug;28(4):482-93
pubmed: 24989448
Br J Anaesth. 2019 Apr;122(4):448-459
pubmed: 30857601
Medicine (Baltimore). 2020 May;99(20):e20001
pubmed: 32443302
Crit Care. 2018 Mar 20;22(1):71
pubmed: 29558988
Anesth Analg. 2000 Dec;91(6):1389-91, TOC
pubmed: 11093985
Anesth Essays Res. 2010 Jul-Dec;4(2):106-8
pubmed: 25885240

Auteurs

Shiori Tanaka (S)

Department of Anesthesiology, Aidu Chuo Hospital, 1-1, Tsuruga-machi, Aizuwakamatsu, Fukushima, 965-8611, Japan. shioripooh113@gmail.com.
Department of Anesthesiology, Fukushima Medical University, 1, Hikariga-oka, Fukushima, Fukushima, 960-1297, Japan. shioripooh113@gmail.com.

Keisuke Yoshida (K)

Department of Anesthesiology, Aidu Chuo Hospital, 1-1, Tsuruga-machi, Aizuwakamatsu, Fukushima, 965-8611, Japan.
Department of Anesthesiology, Fukushima Medical University, 1, Hikariga-oka, Fukushima, Fukushima, 960-1297, Japan.

Kenichi Muramatsu (K)

Department of Cardiovascular Surgery, Aidu Chuo Hospital, 1-1, Tsuruga-machi, Aizuwakamatsu, Fukushima, 965-8611, Japan.

Shigeki Yamagishi (S)

Department of Pulmonology, Aidu Chuo Hospital, 1-1, Tsuruga-machi, Aizuwakamatsu, Fukushima, 965-8611, Japan.

Shinju Obara (S)

Department of Anesthesiology, Fukushima Medical University, 1, Hikariga-oka, Fukushima, Fukushima, 960-1297, Japan.

Kazuhiro Watanabe (K)

Department of Anesthesiology, Aidu Chuo Hospital, 1-1, Tsuruga-machi, Aizuwakamatsu, Fukushima, 965-8611, Japan.

Classifications MeSH