Deep Learning in ex-vivo Lung Cancer Discrimination using Fluorescence Lifetime Endomicroscopic Images.
Journal
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
ISSN: 2694-0604
Titre abrégé: Annu Int Conf IEEE Eng Med Biol Soc
Pays: United States
ID NLM: 101763872
Informations de publication
Date de publication:
07 2020
07 2020
Historique:
entrez:
6
10
2020
pubmed:
7
10
2020
medline:
24
10
2020
Statut:
ppublish
Résumé
Fluorescence lifetime is effective in discriminating cancerous tissue from normal tissue, but conventional discrimination methods are primarily based on statistical approaches in collaboration with prior knowledge. This paper investigates the application of deep convolutional neural networks (CNNs) for automatic differentiation of ex-vivo human lung cancer via fluorescence lifetime imaging. Around 70,000 fluorescence images from ex-vivo lung tissue of 14 patients were collected by a custom fibre-based fluorescence lifetime imaging endomicroscope. Five state-of-the-art CNN models, namely ResNet, ResNeXt, Inception, Xception, and DenseNet, were trained and tested to derive quantitative results using accuracy, precision, recall, and the area under receiver operating characteristic curve (AUC) as the metrics. The CNNs were firstly evaluated on lifetime images. Since fluorescence lifetime is independent of intensity, further experiments were conducted by stacking intensity and lifetime images together as the input to the CNNs. As the original CNNs were implemented for RGB images, two strategies were applied. One was retaining the CNNs by putting intensity and lifetime images in two different channels and leaving the remaining channel blank. The other was adapting the CNNs for two-channel input. Quantitative results demonstrate that the selected CNNs are considerably superior to conventional machine learning algorithms. Combining intensity and lifetime images introduces noticeable performance gain compared with using lifetime images alone. In addition, the CNNs with intensity-lifetime RGB image is comparable to the modified two-channel CNNs with intensity-lifetime two-channel input for accuracy and AUC, but significantly better for precision and recall.
Identifiants
pubmed: 33018370
doi: 10.1109/EMBC44109.2020.9175598
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
1891-1894Subventions
Organisme : Medical Research Council
ID : MR/R017794/1
Pays : United Kingdom