Traumatic index extensor tendon attenuation mimicking closed tendon rupture: two case reports.


Journal

BMC musculoskeletal disorders
ISSN: 1471-2474
Titre abrégé: BMC Musculoskelet Disord
Pays: England
ID NLM: 100968565

Informations de publication

Date de publication:
10 Oct 2020
Historique:
received: 18 07 2020
accepted: 30 09 2020
entrez: 11 10 2020
pubmed: 12 10 2020
medline: 15 5 2021
Statut: epublish

Résumé

While some traumatic closed index extensor tendon ruptures at the musclotendinous junction have been previously reported, closed index extensor tendon pseudorupture due to intertendinous attenuation is exceedingly rare with only one case report of a gymnastics-related sports injury in the English literature. Herein, we report two non-sports injury related cases of traumatic index extensor tendon attenuation mimicking closed tendon rupture, including the pathological findings and intraoperative video of the attenuated extensor indicis proprius tendon. A 28-year-old man and a 30-year-old man caught their hands in a high-speed drill and lathe, respectively, which caused a sudden forced flexion of their wrists. They could not actively extend the metacarpophalangeal joints of their index fingers. Intraoperatively, although the extensor indicis proprius and index extensor digitorum communes tendons were in continuity without ruptures, both tendons were attenuated and stretched. The attenuated index extensor tendons were reconstructed either with shortening by plication or step-cut when the tendon damage was less severe or, in severely attenuated tendons, with tendon grafting (ipsilateral palmaris longus) or tendon transfer. Six months after the operation, the active extension of the index metacarpophalangeal joints had recovered well. Two cases of traumatic index extensor tendon attenuation were treated successfully by shortening the attenuated tendon in combination with tendon graft or transfer. We recommend WALANT (wide-awake local anesthesia and no tourniquet) in the reconstruction surgery of index extensor tendon attenuation to determine the appropriate amount of tendon shortening or optimal tension for tendon grafting or transfer. Intraoperative voluntary finger movement is essential, as it is otherwise difficult to judge the stretch length of intratendinous elongation and extent of traumatic intramuscular damage affecting tendon excursion.

Sections du résumé

BACKGROUND BACKGROUND
While some traumatic closed index extensor tendon ruptures at the musclotendinous junction have been previously reported, closed index extensor tendon pseudorupture due to intertendinous attenuation is exceedingly rare with only one case report of a gymnastics-related sports injury in the English literature. Herein, we report two non-sports injury related cases of traumatic index extensor tendon attenuation mimicking closed tendon rupture, including the pathological findings and intraoperative video of the attenuated extensor indicis proprius tendon.
CASE PRESENTATION METHODS
A 28-year-old man and a 30-year-old man caught their hands in a high-speed drill and lathe, respectively, which caused a sudden forced flexion of their wrists. They could not actively extend the metacarpophalangeal joints of their index fingers. Intraoperatively, although the extensor indicis proprius and index extensor digitorum communes tendons were in continuity without ruptures, both tendons were attenuated and stretched. The attenuated index extensor tendons were reconstructed either with shortening by plication or step-cut when the tendon damage was less severe or, in severely attenuated tendons, with tendon grafting (ipsilateral palmaris longus) or tendon transfer. Six months after the operation, the active extension of the index metacarpophalangeal joints had recovered well.
CONCLUSIONS CONCLUSIONS
Two cases of traumatic index extensor tendon attenuation were treated successfully by shortening the attenuated tendon in combination with tendon graft or transfer. We recommend WALANT (wide-awake local anesthesia and no tourniquet) in the reconstruction surgery of index extensor tendon attenuation to determine the appropriate amount of tendon shortening or optimal tension for tendon grafting or transfer. Intraoperative voluntary finger movement is essential, as it is otherwise difficult to judge the stretch length of intratendinous elongation and extent of traumatic intramuscular damage affecting tendon excursion.

Identifiants

pubmed: 33038920
doi: 10.1186/s12891-020-03692-6
pii: 10.1186/s12891-020-03692-6
pmc: PMC7547513
doi:

Types de publication

Case Reports Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

672

Références

Clin Orthop Relat Res. 1997 Dec;(345):171-3
pubmed: 9418636
J Hand Surg Eur Vol. 2009 Aug;34(4):554-5
pubmed: 19675048
Br J Sports Med. 1993 Jun;27(2):92-3
pubmed: 8358591
J Hand Surg Am. 1995 May;20(3):474-7
pubmed: 7642930
J Hand Surg Am. 2013 Dec;38(12):2335-8
pubmed: 24161473
J Hand Ther. 2012 Apr-Jun;25(2):133-40; quiz 141
pubmed: 21925835
J Hand Surg Eur Vol. 2007 Dec;32(6):675-6
pubmed: 17993430
Exerc Sport Sci Rev. 1978;6:125-81
pubmed: 394967
J Biomech. 2006;39(9):1563-82
pubmed: 16000201
Hand (N Y). 2011 Mar;6(1):90-2
pubmed: 22379446

Auteurs

Yusuke Miyashima (Y)

Department of Orthopedic Surgery, Osaka General Hospital of West Japan Railway Company, 1-2-22 Matsuzakicho, Abeno-ku, Osaka, 545-0053, Japan.

Takuya Uemura (T)

Department of Orthopedic Surgery, Osaka General Hospital of West Japan Railway Company, 1-2-22 Matsuzakicho, Abeno-ku, Osaka, 545-0053, Japan. t-uemura@med.osaka-cu.ac.jp.
Department of Orthopedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3, Asahimachi, Abeno-ku, Osaka, 545-8585, Japan. t-uemura@med.osaka-cu.ac.jp.

Takuya Yokoi (T)

Department of Orthopedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3, Asahimachi, Abeno-ku, Osaka, 545-8585, Japan.

Shunpei Hama (S)

Department of Orthopedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3, Asahimachi, Abeno-ku, Osaka, 545-8585, Japan.

Mitsuhiro Okada (M)

Department of Orthopedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3, Asahimachi, Abeno-ku, Osaka, 545-8585, Japan.

Sadahiko Konishi (S)

Department of Orthopedic Surgery, Osaka General Hospital of West Japan Railway Company, 1-2-22 Matsuzakicho, Abeno-ku, Osaka, 545-0053, Japan.

Hiroaki Nakamura (H)

Department of Orthopedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3, Asahimachi, Abeno-ku, Osaka, 545-8585, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH