Low-cost procedure for deformity correction in rheumatoid hands.


Journal

Scottish medical journal
ISSN: 0036-9330
Titre abrégé: Scott Med J
Pays: Scotland
ID NLM: 2983335R

Informations de publication

Date de publication:
May 2021
Historique:
pubmed: 27 10 2020
medline: 7 10 2021
entrez: 26 10 2020
Statut: ppublish

Résumé

Surgical correction of ulnar drift of metacarpo-phalangeal joint (MPJ) due to Rheumatoid arthritis (RA) is conventionally done by silicon joint arthroplasty which is expensive and may be associated with many complications. We report the outcome of low-cost autologous interpositional arthroplasty. Five patients (8 hands, 32 arthroplasties) underwent correction of ulnar drift of MPJ by dorsal capsule interpositional arthroplasty. Results were assessed according to the degree of recovery of movement at the MPJ and correction of ulnar drift. Functional improvement was graded as excellent, good and fair. Pain alleviation was assessed by visual analogue score (VAS) score. Excellent results were seen in 3 patients (5 hands, 20 arthroplasties), good in 1 patient (2 hands, 8 arthroplasties) and fair in 1 patient (1 hand, 4 arthroplasties). VAS score for pain decreased from mean preoperative 8.2/10 to 1/10. On average follow up of 1.4 years there was good hand function, no recurrence of deformities and patients were pain free. Interpositional arthroplasty for MPJ using dorsal capsule for correction of post RA ulnar drift is a low-cost option which improves the hand function and cosmesis. Additionally, it avoids all the complications related with the use of silicon joints.

Sections du résumé

BACKGROUND BACKGROUND
Surgical correction of ulnar drift of metacarpo-phalangeal joint (MPJ) due to Rheumatoid arthritis (RA) is conventionally done by silicon joint arthroplasty which is expensive and may be associated with many complications. We report the outcome of low-cost autologous interpositional arthroplasty.
MATERIAL AND METHODS METHODS
Five patients (8 hands, 32 arthroplasties) underwent correction of ulnar drift of MPJ by dorsal capsule interpositional arthroplasty. Results were assessed according to the degree of recovery of movement at the MPJ and correction of ulnar drift. Functional improvement was graded as excellent, good and fair. Pain alleviation was assessed by visual analogue score (VAS) score.
RESULTS RESULTS
Excellent results were seen in 3 patients (5 hands, 20 arthroplasties), good in 1 patient (2 hands, 8 arthroplasties) and fair in 1 patient (1 hand, 4 arthroplasties). VAS score for pain decreased from mean preoperative 8.2/10 to 1/10. On average follow up of 1.4 years there was good hand function, no recurrence of deformities and patients were pain free.
CONCLUSION CONCLUSIONS
Interpositional arthroplasty for MPJ using dorsal capsule for correction of post RA ulnar drift is a low-cost option which improves the hand function and cosmesis. Additionally, it avoids all the complications related with the use of silicon joints.

Identifiants

pubmed: 33103568
doi: 10.1177/0036933020969006
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

77-83

Auteurs

Pawan Agarwal (P)

Professor and In Charge Plastic Surgery Unit, Department of Surgery, NSCB Government Medical College, Jabalpur, India.

Raju Vaishya (R)

Professor and Orthopaedic Surgeon, Department of Orthopedics, Indraprastha Apollo Hospitals, New Delhi, India.

Dhananjaya Sharma (D)

Professor and Head, Department of Surgery, NSCB Government Medical College, Jabalpur, India.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH