Two reconstruction plates provide superior stability of displaced midshaft clavicle fractures in comparison to single plating - A biomechanical study.

Biomechanical testing Clavicle Dynamic compression plate Locking compression plate Midshaft fracture Reconstruction plate

Journal

Clinical biomechanics (Bristol, Avon)
ISSN: 1879-1271
Titre abrégé: Clin Biomech (Bristol, Avon)
Pays: England
ID NLM: 8611877

Informations de publication

Date de publication:
12 2020
Historique:
received: 05 10 2020
accepted: 16 10 2020
pubmed: 2 11 2020
medline: 24 4 2021
entrez: 1 11 2020
Statut: ppublish

Résumé

Displaced midshaft fractures are the most common surgically treated clavicle fractures. However, they are associated with high complication rates following plating due to fixation failure in terms of plate breakage, screw breakage and/or screw loosening. The aim of this study was to compare the biomechanical competence of three different plating techniques for fixation of displaced midshaft clavicle fractures. Displaced midshaft fractures type 2B according to the Robinson classification were simulated by standardized osteotomy gap in 18 synthetic clavicles, assigned to three groups (n = 6) for plating with either superiorly placed Dynamic Compression Plate (width/thickness 11.0/4.0 mm), locked Superior Anterior Clavicle Locking Compression Plate (width/thickness 10.2/2.0 mm), or two non-locked Reconstruction Plates placed superiorly and anteriorly (width/thickness 10.0/2.8 mm). Each specimen was cyclically tested at 3 Hz under craniocaudal cantilever bending, superimposed with torsion around the shaft axis over 720'000 cycles or until failure occurred. The latter was defined by plate breakage, screw breakage or screw loosening. Initial construct stiffness (N/mm) and cycles to failure in group Reconstruction Plates (22.30 ± 4.07; 712'778 ± 17'691) were significantly higher compared with both groups Compression Plate (12.53 ± 2.09; 348'541 ± 212'941) and Locking Plate (4.19 ± 0.46; 19'536 ± 3'586), p ≤ 0.019. In addition, these two outcomes were significantly higher in group Compression Plate versus Locking Plate, p ≤ 0.029. Double plating of unstable midshaft clavicle fractures with reconstruction plates seems to provide superior fixation stability under dynamic loading, when compared to single compression or locked plating, whereas the latter is associated with inferior performance.

Sections du résumé

BACKGROUND
Displaced midshaft fractures are the most common surgically treated clavicle fractures. However, they are associated with high complication rates following plating due to fixation failure in terms of plate breakage, screw breakage and/or screw loosening. The aim of this study was to compare the biomechanical competence of three different plating techniques for fixation of displaced midshaft clavicle fractures.
METHODS
Displaced midshaft fractures type 2B according to the Robinson classification were simulated by standardized osteotomy gap in 18 synthetic clavicles, assigned to three groups (n = 6) for plating with either superiorly placed Dynamic Compression Plate (width/thickness 11.0/4.0 mm), locked Superior Anterior Clavicle Locking Compression Plate (width/thickness 10.2/2.0 mm), or two non-locked Reconstruction Plates placed superiorly and anteriorly (width/thickness 10.0/2.8 mm). Each specimen was cyclically tested at 3 Hz under craniocaudal cantilever bending, superimposed with torsion around the shaft axis over 720'000 cycles or until failure occurred. The latter was defined by plate breakage, screw breakage or screw loosening.
FINDINGS
Initial construct stiffness (N/mm) and cycles to failure in group Reconstruction Plates (22.30 ± 4.07; 712'778 ± 17'691) were significantly higher compared with both groups Compression Plate (12.53 ± 2.09; 348'541 ± 212'941) and Locking Plate (4.19 ± 0.46; 19'536 ± 3'586), p ≤ 0.019. In addition, these two outcomes were significantly higher in group Compression Plate versus Locking Plate, p ≤ 0.029.
INTERPRETATION
Double plating of unstable midshaft clavicle fractures with reconstruction plates seems to provide superior fixation stability under dynamic loading, when compared to single compression or locked plating, whereas the latter is associated with inferior performance.

Identifiants

pubmed: 33129563
pii: S0268-0033(20)30318-1
doi: 10.1016/j.clinbiomech.2020.105199
pii:
doi:

Types de publication

Comparative Study Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

105199

Informations de copyright

Copyright © 2020. Published by Elsevier Ltd.

Auteurs

Parvan Yanev (P)

AO Research Institute Davos, Davos, Switzerland; University Multiprofile Hospital for Active Treatment and Emergency Medicine "N. I. Pirogov", Sofia, Bulgaria. Electronic address: parvanyanev999@gmail.com.

Ivan Zderic (I)

AO Research Institute Davos, Davos, Switzerland.

Yavor Pukalski (Y)

AO Research Institute Davos, Davos, Switzerland; University Multiprofile Hospital for Active Treatment and Emergency Medicine "N. I. Pirogov", Sofia, Bulgaria.

Dian Enchev (D)

University Multiprofile Hospital for Active Treatment and Emergency Medicine "N. I. Pirogov", Sofia, Bulgaria.

Mihail Rashkov (M)

University Multiprofile Hospital for Active Treatment and Emergency Medicine "N. I. Pirogov", Sofia, Bulgaria.

Peter Varga (P)

AO Research Institute Davos, Davos, Switzerland.

Dominic Gehweiler (D)

AO Research Institute Davos, Davos, Switzerland.

Geoff Richards (G)

AO Research Institute Davos, Davos, Switzerland.

Boyko Gueorguiev (B)

AO Research Institute Davos, Davos, Switzerland.

Asen Baltov (A)

University Multiprofile Hospital for Active Treatment and Emergency Medicine "N. I. Pirogov", Sofia, Bulgaria.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH