Computational fluid dynamics of internal mammary artery-left anterior descending artery anastomoses.
Aged
Aged, 80 and over
Anastomosis, Surgical
/ methods
Computed Tomography Angiography
Coronary Vessels
/ physiopathology
Hemodynamics
Humans
Hydrodynamics
Internal Mammary-Coronary Artery Anastomosis
/ methods
Male
Mammary Arteries
/ physiopathology
Middle Aged
Patient-Specific Modeling
Pulsatile Flow
/ physiology
Stress, Mechanical
Anastomosis
Fluid dynamics
Internal mammary artery
Left anterior descending artery
Journal
Interactive cardiovascular and thoracic surgery
ISSN: 1569-9285
Titre abrégé: Interact Cardiovasc Thorac Surg
Pays: England
ID NLM: 101158399
Informations de publication
Date de publication:
01 11 2020
01 11 2020
Historique:
received:
19
04
2020
revised:
01
07
2020
accepted:
20
07
2020
entrez:
2
11
2020
pubmed:
3
11
2020
medline:
9
6
2021
Statut:
ppublish
Résumé
The aim of this study was to elucidate the remodelling of the internal mammary artery (IMA)-left anterior descending artery anastomosis and compare 2 different anastomosis techniques (end-to-side versus side-to-side) using computational fluid dynamics. This study included 9 patients. Computed tomography (CT) angiography was performed immediately after coronary artery bypass grafting (CABG) and at 3-6 months later. The computational fluid dynamics models were made using the CT data. The pulsatile 3-dimensional blood flow was achieved with the finite volume method to evaluate the postoperative morphological and haemodynamic changes at the anastomosis in each patient. Flow velocity distribution, wall shear stress (WSS) and its fluctuation oscillatory shear index were measured. No early or mid-term graft occlusion was observed in the study series. In the side-to-side anastomosis, pouch formation at the distal end of IMA caused a vortex flow with low WSS immediately after CABG. However, at 3-6 months after surgery, this pouch disappeared. As a result, the laminar straight flow with uniform WSS distribution was achieved inside the anastomosis. In the end-to-side anastomosis, the anastomosis shape was remodelled, resulting in a laminar flow pattern with uniform WSS distribution. A patchy high oscillatory shear index was detected at the IMA wall on the top of anastomosis in either anastomosis techniques immediately after the surgery, but it disappeared at 3-6 months after surgery. Regardless of the anastomosis technique used, a successful remodelling of the IMA-left anterior descending artery anastomosis shape was achieved a few months after surgery, resulting in a straightforward flow streamline, with uniform WSS distribution and minimal oscillatory shear index.