Analysis of serum tranexamic acid in patients undergoing open heart surgery.
Cardiac surgery
LC-MS/MS
Serum
Tranexamic acid
Journal
Clinical biochemistry
ISSN: 1873-2933
Titre abrégé: Clin Biochem
Pays: United States
ID NLM: 0133660
Informations de publication
Date de publication:
Jan 2021
Jan 2021
Historique:
received:
31
05
2020
revised:
07
10
2020
accepted:
21
10
2020
pubmed:
15
11
2020
medline:
25
5
2021
entrez:
14
11
2020
Statut:
ppublish
Résumé
Tranexamic acid is a drug used during open cardiac surgery to prevent blood loss. The blood levels of 10-100 µg/mL are reported to be in the therapeutic range and higher levels are linked to increased incidence of adverse effects. The aim of this study was to optimize and validate an LC-MS/MS method for serum tranexamic acid and measure its levels in patients from the DEPOSITION Pilot trial in order to prove the concept that topical administration will yield lower serum concentration. The method development was carried out in several steps including sample preparation, and optimization of chromatography and tandem mass spectrometry parameters. Method validation including day-to-day precision with 4 QC levels, limit of detection, sample stability, carryover, and concentration-signal linearity was carried out. Ninety patient samples were analyzed using the validated method. Fast and efficient LC-MS/MS method for analysis of tranexamic acid in serum was developed. The run time was 7 min with the total time of one hour including the sample preparation. The method precision was acceptable (%CV = 10.5-12.6%) with no sample carryover observed. The matrix effect on the analytical sensitivity was negligible and the lower limit of detection was 0.5 µg/mL. The difference in the mean adjusted concentrations between topical (45 patients) and intravenous (45 patients) groups was statistically significant (0.1154 µg/mL/kg vs. 0.2542 µg/mL/kg, p < 0.0001) CONCLUSIONS: Rapid and simple LC-MS/MS method for analysis of tranexamic acid was optimized and validated. The laboratory has played a crucial role in proving the concept that topical administration yields significantly lower systemic levels of tranexamic acid, and thus decreases the risk of adverse outcomes in patients undergoing open cardiac surgery.
Sections du résumé
BACKGROUND
BACKGROUND
Tranexamic acid is a drug used during open cardiac surgery to prevent blood loss. The blood levels of 10-100 µg/mL are reported to be in the therapeutic range and higher levels are linked to increased incidence of adverse effects. The aim of this study was to optimize and validate an LC-MS/MS method for serum tranexamic acid and measure its levels in patients from the DEPOSITION Pilot trial in order to prove the concept that topical administration will yield lower serum concentration.
METHODS
METHODS
The method development was carried out in several steps including sample preparation, and optimization of chromatography and tandem mass spectrometry parameters. Method validation including day-to-day precision with 4 QC levels, limit of detection, sample stability, carryover, and concentration-signal linearity was carried out. Ninety patient samples were analyzed using the validated method.
RESULTS
RESULTS
Fast and efficient LC-MS/MS method for analysis of tranexamic acid in serum was developed. The run time was 7 min with the total time of one hour including the sample preparation. The method precision was acceptable (%CV = 10.5-12.6%) with no sample carryover observed. The matrix effect on the analytical sensitivity was negligible and the lower limit of detection was 0.5 µg/mL. The difference in the mean adjusted concentrations between topical (45 patients) and intravenous (45 patients) groups was statistically significant (0.1154 µg/mL/kg vs. 0.2542 µg/mL/kg, p < 0.0001) CONCLUSIONS: Rapid and simple LC-MS/MS method for analysis of tranexamic acid was optimized and validated. The laboratory has played a crucial role in proving the concept that topical administration yields significantly lower systemic levels of tranexamic acid, and thus decreases the risk of adverse outcomes in patients undergoing open cardiac surgery.
Identifiants
pubmed: 33188769
pii: S0009-9120(20)30872-9
doi: 10.1016/j.clinbiochem.2020.10.010
pii:
doi:
Substances chimiques
Tranexamic Acid
6T84R30KC1
Types de publication
Journal Article
Randomized Controlled Trial
Langues
eng
Sous-ensembles de citation
IM
Pagination
74-78Informations de copyright
Copyright © 2020 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.