Résumé
To evaluate an image-navigated isotropic high-resolution 3D late gadolinium enhancement (LGE) prototype sequence with compressed sensing and Dixon water-fat separation in a clinical routine setting. Forty consecutive patients scheduled for cardiac MRI were enrolled prospectively and examined with 1.5 T MRI. Overall subjective image quality, LGE pattern and extent, diagnostic confidence for detection of LGE, and scan time were evaluated and compared to standard 2D LGE imaging. Robustness of Dixon fat suppression was evaluated for 3D Dixon LGE imaging. For statistical analysis, the non-parametric Wilcoxon rank sum test was performed. LGE was rated as ischemic in 9 patients and non-ischemic in 11 patients while it was absent in 20 patients. Image quality and diagnostic confidence were comparable between both techniques (p = 0.67 and p = 0.66, respectively). LGE extent with respect to segmental or transmural myocardial enhancement was identical between 2D and 3D (water-only and in-phase). LGE size was comparable (3D 8.4 ± 7.2 g, 2D 8.7 ± 7.3 g, p = 0.19). Good or excellent fat suppression was achieved in 93% of the 3D LGE datasets. In 6 patients with pericarditis, the 3D sequence with Dixon fat suppression allowed for a better detection of pericardial LGE. Scan duration was significantly longer for 3D imaging (2D median 9:32 min vs. 3D median 10:46 min, p = 0.001). The 3D LGE sequence provides comparable LGE detection compared to 2D imaging and seems to be superior in evaluating the extent of pericardial involvement in patients suspected with pericarditis due to the robust Dixon fat suppression. • Three-dimensional LGE imaging provides high-resolution detection of myocardial scarring. • Robust Dixon water-fat separation aids in the assessment of pericardial disease. • The 2D image navigator technique enables 100% respiratory scan efficacy and permits predictable scan times.
Identifiants
pubmed: 33263160
doi: 10.1007/s00330-020-07517-x
pii: 10.1007/s00330-020-07517-x
pmc: PMC8128857
doi:
Substances chimiques
Contrast Media
0
Water
059QF0KO0R
Gadolinium
AU0V1LM3JT
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
3951-3961Subventions
Organisme : Medical Research Council
ID : MR/L009676/1
Pays : United Kingdom
Références
Ordovas KG, Higgins CB (2011) Delayed contrast enhancement on MR images of myocardium: past, present, future. Radiology 261:358–374
doi: 10.1148/radiol.11091882
pubmed: 22012903
Doltra A, Amundsen BH, Gebker R et al (2013) Emerging concepts for myocardial late gadolinium enhancement MRI. Curr Cardiol Rev 9:185–190
doi: 10.2174/1573403X113099990030
pubmed: 23909638
Kim RJ, Shah DJ, Judd RM (2003) How we perform delayed enhancement imaging. J Cardiovasc Magn Reson 5:505–514
doi: 10.1081/JCMR-120022267
pubmed: 12882082
Kamesh Iyer S, Tasdizen T, Burgon N et al (2016) Compressed sensing for rapid late gadolinium enhanced imaging of the left atrium: a preliminary study. Magn Reson Imaging 34:846–854
doi: 10.1016/j.mri.2016.03.002
pubmed: 26968143
Akçakaya M, Rayatzadeh H, Basha TA et al (2012) Accelerated late gadolinium enhancement cardiac MR imaging with isotropic spatial resolution using compressed sensing: initial experience. Radiology 264:691–699
doi: 10.1148/radiol.12112489
pubmed: 3426855
Adluru G, Chen L, Kim S-E et al (2011) Three-dimensional late gadolinium enhancement imaging of the left atrium with a hybrid radial acquisition and compressed sensing. J Magn Reson Imaging 34:1465–1471
doi: 10.1002/jmri.22808
pubmed: 21972108
Goetti R, Kozerke S, Donati OF et al (2011) Acute, subacute, and chronic myocardial infarction: quantitative comparison of 2D and 3D late gadolinium enhancement MR imaging. Radiology 259:704–711
doi: 10.1148/radiol.11102216
Piehler KM, Wong TC, Puntil KS et al (2013) Free-breathing, motion-corrected late gadolinium enhancement is robust and extends risk stratification to vulnerable patients. Circ Cardiovasc Imaging 6:423–432
doi: 10.1161/CIRCIMAGING.112.000022
pubmed: 4066466
Henningsson M, Smink J, van Ensbergen G, Botnar R (2018) Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency. Magn Reson Med 79:416–422
doi: 10.1002/mrm.26678
Bratis K, Henningsson M, Grigoratos C et al (2017) Image-navigated 3-dimensional late gadolinium enhancement cardiovascular magnetic resonance imaging: feasibility and initial clinical results. J Cardiovasc Magn Reson 19:97
doi: 10.1186/s12968-017-0418-7
pubmed: 29202776
Rutz T, Piccini D, Coppo S et al (2016) Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach. Int J Cardiovasc Imaging 32:1735–1744
doi: 10.1007/s10554-016-0963-4
pubmed: 27549804
Henningsson M, Koken P, Stehning C et al (2012) Whole-heart coronary MR angiography with 2D self-navigated image reconstruction. Magn Reson Med 67:437–445
doi: 10.1002/mrm.23027
pubmed: 21656563
Bratis K, Henningsson M, Grigoratos C et al (2017) Clinical evaluation of three-dimensional late enhancement MRI. J Magn Reson Imaging 45:1675–1683
doi: 10.1002/jmri.25512
pubmed: 27801994
Donoho DL (2006) Compressed sensing. IEEE Trans Inf Theory 52:1289–1306
doi: 10.1109/TIT.2006.871582
Candès E, Romberg J (2007) Sparsity and incoherence in compressive sampling. Inverse Probl 23:969–985
doi: 10.1088/0266-5611/23/3/008
Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195
doi: 10.1002/mrm.21391
pubmed: 17969013
Forman C, Wetzl J, Hayes C, Schmidt M (2016) Compressed sensing: a paradigm shift in MRI. MAGNETOM Flash 66:9–13
Goldfarb JW (2008) Fat-water separated delayed hyperenhanced myocardial infarct imaging. Magn Reson Med 60:503–509
doi: 10.1002/mrm.21685
pubmed: 18727051
Peters DC, Dokhan B, Nezafat R et al (2009) Effective fat-suppression for late gadolinium enhancement combined with a sequential acquisition order. J Cardiovasc Magn Reson 11:P75
doi: 10.1186/1532-429X-11-S1-P75
Kellman P, Hernando D, Shah S et al (2009) Multiecho Dixon fat and water separation method for detecting fibrofatty infiltration in the myocardium. Magn Reson Med 61:215–221
doi: 10.1002/mrm.21657
pubmed: 2710534
Shaw JL, Knowles BR, Goldfarb JW et al (2014) Left atrial late gadolinium enhancement with water-fat separation: the importance of phase-encoding order. J Magn Reson Imaging 40:119–125
doi: 10.1002/jmri.24340
Kramer CM, Barkhausen J, Flamm SD et al (2013) Standardized cardiovascular magnetic resonance (CMR) protocols 2013 update. J Cardiovasc Magn Reson 15:91
doi: 10.1186/1532-429X-15-91
pubmed: 3851953
Kramer CM, Barkhausen J, Bucciarelli-Ducci C et al (2020) Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update. J Cardiovasc Magn Reson 22:17
doi: 10.1186/s12968-020-00607-1
pubmed: 7038611
Prieto C, Doneva M, Usman M et al (2015) Highly efficient respiratory motion compensated free-breathing coronary MRA using golden-step Cartesian acquisition. J Magn Reson Imaging 41:738–746
doi: 10.1002/jmri.24602
Munoz C, Cruz G, Neji R et al (2019) Motion corrected water/fat whole-heart coronary MR angiography with 100% respiratory efficiency. Magn Reson Med 82:732–742
doi: 10.1002/mrm.27732
pubmed: 6563440
Kunze KP, Piccini D, Forman C (2019) 3D whole-heart imaging with orientation-independent 2D image navigators. In: Soc Magn Reson Angiogr 31st Annu Int Conf. 2019, p 25
Forman C, Piccini D, Grimm R et al (2014) High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation. MAGMA 27:435–443
doi: 10.1007/s10334-013-0428-x
Beck A, Teboulle M (2009) A fast iterative shrinkage-thresholding algorithm for linear inverse problems. SIAM J Imaging Sci 2:183–202
doi: 10.1137/080716542
Saranathan M, Glockner J (2013) Three-dimensional Dixon fat-water separated rapid breathheld imaging of myocardial infarction: 3D fat suppressed imaging of infarction. J Magn Reson Imaging 38:1362–1368
doi: 10.1002/jmri.24113
Cerqueira MD, Weissman NJ, Dilsizian V et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–542
doi: 10.1161/hc0402.102975
Havla L, Basha T, Rayatzadeh H et al (2013) Improved fat water separation with water selective inversion pulse for inversion recovery imaging in cardiac MRI. J Magn Reson Imaging 37:484–490
doi: 10.1002/jmri.23779
pubmed: 22927327
Andreu D, Ortiz-Pérez JT, Fernández-Armenta J et al (2015) 3D delayed-enhanced magnetic resonance sequences improve conducting channel delineation prior to ventricular tachycardia ablation. Europace 17:938–945
doi: 10.1093/europace/euu310
pubmed: 25616406
Selvanayagam JB, Kardos A, Francis JM et al (2004) Value of delayed-enhancement cardiovascular magnetic resonance imaging in predicting myocardial viability after surgical revascularization. Circulation 110:1535–1541
doi: 10.1161/01.CIR.0000142045.22628.74
pubmed: 15353496
Cruz G, Atkinson D, Henningsson M et al (2017) Highly efficient nonrigid motion-corrected 3D whole-heart coronary vessel wall imaging. Magn Reson Med 77:1894–1908
doi: 10.1002/mrm.26274
pubmed: 27221073
Luo J, Addy NO, Ingle RR et al (2017) Nonrigid motion correction with 3D image-based navigators for coronary MR angiography. Magn Reson Med 77:1884–1893
doi: 10.1002/mrm.26273
pubmed: 27174673
Keegan J, Gatehouse PD, Haldar S et al (2015) Dynamic inversion time for improved 3D late gadolinium enhancement imaging in patients with atrial fibrillation. Magn Reson Med 73:646–654
doi: 10.1002/mrm.25190
pubmed: 24604664
Behl NGR, Gnahm C, Bachert P et al (2016) Three-dimensional dictionary-learning reconstruction of (23)Na MRI data. Magn Reson Med 75:1605–1616
doi: 10.1002/mrm.25759
pubmed: 25989746